- CVE-2011-4531
Vulnerability Details
View details for CVE-2011-4531
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
Open full assessment ↗ - CVE-2011-4530
Vulnerability Details
View details for CVE-2011-4530
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1) open_session->workstation->NAME or (2) grant->VERSION function.
Open full assessment ↗ - CVE-2011-4529
Vulnerability Details
View details for CVE-2011-4529
Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command.
Open full assessment ↗ - CVE-2011-4528
Vulnerability Details
View details for CVE-2011-4528
Unbound before 1.4.13p2 attempts to free unallocated memory during processing of duplicate CNAME records in a signed zone, which allows remote DNS servers to cause a denial of service (daemon crash) via a crafted response.
Open full assessment ↗ - CVE-2011-4526
Vulnerability Details
View details for CVE-2011-4526
Buffer overflow in an ActiveX control in Advantech/BroadWin WebAccess before 7.0 might allow remote attackers to execute arbitrary code via a long string value in unspecified parameters.
Open full assessment ↗ - CVE-2011-4525
Vulnerability Details
View details for CVE-2011-4525
Advantech/BroadWin WebAccess before 7.0 allows remote attackers to trigger the extraction of arbitrary web content into a batch file on a client system, and execute this batch file, via unspecified vectors.
Open full assessment ↗ - CVE-2011-4524
Vulnerability Details
View details for CVE-2011-4524
Buffer overflow in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary code via a long string value in unspecified parameters.
Open full assessment ↗ - CVE-2011-4523
Vulnerability Details
View details for CVE-2011-4523
Cross-site scripting (XSS) vulnerability in bwview.asp in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to inject arbitrary web script or HTML via unspecified parameters.
Open full assessment ↗ - CVE-2011-4522
Vulnerability Details
View details for CVE-2011-4522
Cross-site scripting (XSS) vulnerability in bwerrdn.asp in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to inject arbitrary web script or HTML via unspecified parameters.
Open full assessment ↗ - CVE-2011-4521
Vulnerability Details
View details for CVE-2011-4521
SQL injection vulnerability in Advantech/BroadWin WebAccess before 7.0 allows remote attackers to execute arbitrary SQL commands via crafted string input.
Open full assessment ↗ - CVE-2011-4520
Vulnerability Details
View details for CVE-2011-4520
Heap-based buffer overflow in an ActiveX component in MICROSYS PROMOTIC before 8.1.5 allows remote attackers to cause a denial of service via a crafted web page.
Open full assessment ↗ - CVE-2011-4519
Vulnerability Details
View details for CVE-2011-4519
Stack-based buffer overflow in an ActiveX component in MICROSYS PROMOTIC before 8.1.5 allows remote attackers to cause a denial of service via a crafted web page.
Open full assessment ↗ - CVE-2011-4518
Vulnerability Details
View details for CVE-2011-4518
Directory traversal vulnerability in the PmWebDir object in the web server in MICROSYS PROMOTIC before 8.1.5 allows remote attackers to read arbitrary files via unspecified vectors.
Open full assessment ↗ - CVE-2011-4517
Vulnerability Details
View details for CVE-2011-4517
The jpc_crg_getparms function in libjasper/jpc/jpc_cs.c in JasPer 1.900.1 uses an incorrect data type during a certain size calculation, which allows remote attackers to trigger a heap-based buffer overflow and execute arbitrary code, or cause a denial of service (heap memory corruption), via a crafted component registration (CRG) marker segment in a JPEG2000 file.
Open full assessment ↗ - CVE-2011-4516
Vulnerability Details
View details for CVE-2011-4516
Heap-based buffer overflow in the jpc_cox_getcompparms function in libjasper/jpc/jpc_cs.c in JasPer 1.900.1 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted numrlvls value in a coding style default (COD) marker segment in a JPEG2000 file.
Open full assessment ↗ - CVE-2011-4515
Vulnerability Details
View details for CVE-2011-4515
Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access.
Open full assessment ↗ - CVE-2011-4514
Vulnerability Details
View details for CVE-2011-4514
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session.
Open full assessment ↗ - CVE-2011-4513
Vulnerability Details
View details for CVE-2011-4513
Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader.
Open full assessment ↗ - CVE-2011-4512
Vulnerability Details
View details for CVE-2011-4512
CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors.
Open full assessment ↗ - CVE-2011-4511
Vulnerability Details
View details for CVE-2011-4511
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.
Open full assessment ↗ - CVE-2011-4510
Vulnerability Details
View details for CVE-2011-4510
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511.
Open full assessment ↗ - CVE-2011-4509
Vulnerability Details
View details for CVE-2011-4509
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.
Open full assessment ↗ - CVE-2011-4508
Vulnerability Details
View details for CVE-2011-4508
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie.
Open full assessment ↗ - CVE-2011-4507
Vulnerability Details
View details for CVE-2011-4507
The D-Link DIR-685 router, when certain WPA and WPA2 configurations are used, does not maintain an encrypted wireless network during transfer of a large amount of network traffic, which allows remote attackers to obtain sensitive information or bypass authentication via a Wi-Fi device.
Open full assessment ↗