CVE 2012 Directory: Page 120
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
5,492 published records with identifiers assigned to 2012. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 120 of 229
- CVE-2012-3040
Vulnerability Details
View details for CVE-2012-3040
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
Open full assessment ↗ - CVE-2012-3039
Vulnerability Details
View details for CVE-2012-3039
Moxa OnCell Gateway G3111, G3151, G3211, and G3251 devices with firmware before 1.4 do not use a sufficient source of entropy for SSH and SSL keys, which makes it easier for remote attackers to obtain access by leveraging knowledge of a key from a product installation elsewhere.
Open full assessment ↗ - CVE-2012-3037
Vulnerability Details
View details for CVE-2012-3037
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
Open full assessment ↗ - CVE-2012-3035
Vulnerability Details
View details for CVE-2012-3035
Buffer overflow in Emerson DeltaV 9.3.1 and 10.3 through 11.3.1 allows remote attackers to cause a denial of service (daemon crash) via a long string to an unspecified port.
Open full assessment ↗ - CVE-2012-3034
Vulnerability Details
View details for CVE-2012-3034
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.
Open full assessment ↗ - CVE-2012-3032
Vulnerability Details
View details for CVE-2012-3032
SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.
Open full assessment ↗ - CVE-2012-3031
Vulnerability Details
View details for CVE-2012-3031
Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.
Open full assessment ↗ - CVE-2012-3030
Vulnerability Details
View details for CVE-2012-3030
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
Open full assessment ↗ - CVE-2012-3028
Vulnerability Details
View details for CVE-2012-3028
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
Open full assessment ↗ - CVE-2012-3026
Vulnerability Details
View details for CVE-2012-3026
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3021.
Open full assessment ↗ - CVE-2012-3025
Vulnerability Details
View details for CVE-2012-3025
The default configuration of Tridium Niagara AX Framework through 3.6 uses a cleartext base64 format for transmission of credentials in cookies, which allows remote attackers to obtain sensitive information by sniffing the network.
Open full assessment ↗ - CVE-2012-3024
Vulnerability Details
View details for CVE-2012-3024
Tridium Niagara AX Framework through 3.6 uses predictable values for (1) session IDs and (2) keys, which might allow remote attackers to bypass authentication via a brute-force attack.
Open full assessment ↗ - CVE-2012-3022
Vulnerability Details
View details for CVE-2012-3022
The SaveToFile method in a certain ActiveX control in TrendDisplay.dll in Canary Labs TrendLink 9.0.2.27051 and earlier does not properly restrict the creation of files, which allows remote attackers to download an arbitrary program onto a client machine, and execute this program, via a crafted web site.
Open full assessment ↗ - CVE-2012-3021
Vulnerability Details
View details for CVE-2012-3021
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.
Open full assessment ↗ - CVE-2012-3020
Vulnerability Details
View details for CVE-2012-3020
The Siemens Synco OZW Web Server devices OZW672.*, OZW772.*, and OZW775 with firmware before 4 have an unspecified default password, which makes it easier for remote attackers to obtain administrative access via a network session.
Open full assessment ↗ - CVE-2012-3018
Vulnerability Details
View details for CVE-2012-3018
The lockout-recovery feature in the Security Configurator component in ICONICS GENESIS32 9.22 and earlier and BizViz 9.22 and earlier uses an improper encryption algorithm for generation of an authentication code, which allows local users to bypass intended access restrictions and obtain administrative access by predicting a challenge response.
Open full assessment ↗ - CVE-2012-3017
Vulnerability Details
View details for CVE-2012-3017
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.
Open full assessment ↗ - CVE-2012-3016
Vulnerability Details
View details for CVE-2012-3016
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.
Open full assessment ↗ - CVE-2012-3015
Vulnerability Details
View details for CVE-2012-3015
Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges via a Trojan horse DLL in a STEP7 project folder.
Open full assessment ↗ - CVE-2012-3014
Vulnerability Details
View details for CVE-2012-3014
The Management Software application in GarrettCom Magnum MNS-6K before 4.4.0, and 14.x before 14.4.0, has a hardcoded password for an administrative account, which allows local users to gain privileges via unspecified vectors.
Open full assessment ↗ - CVE-2012-3013
Vulnerability Details
View details for CVE-2012-3013
WAGO I/O System 758 model 758-870, 758-874, 758-875, and 758-876 Industrial PC (IPC) devices have default passwords for unspecified Web Based Management accounts, which makes it easier for remote attackers to obtain administrative access via a TCP session.
Open full assessment ↗ - CVE-2012-3012
Vulnerability Details
View details for CVE-2012-3012
The Arbiter Power Sentinel 1133A device with firmware before 11Jun2012 Rev 421 allows remote attackers to cause a denial of service (Ethernet outage) via unspecified Ethernet traffic that fills a buffer, as demonstrated by a port scan.
Open full assessment ↗ - CVE-2012-3011
Vulnerability Details
View details for CVE-2012-3011
Directory traversal vulnerability in the web server in Fultek WinTr Scada 4.0.5 and earlier allows remote attackers to read arbitrary files via a crafted request.
Open full assessment ↗ - CVE-2012-3010
Vulnerability Details
View details for CVE-2012-3010
rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3021 and CVE-2012-3026.
Open full assessment ↗