CVE 2013 Directory: Page 158
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
6,222 published records with identifiers assigned to 2013. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 158 of 260
- CVE-2013-2809
Vulnerability Details
View details for CVE-2013-2809
The DNP Master Driver in the OSIsoft PI Interface before 3.1.2.54 for DNP3 allows remote attackers to cause a denial of service (interface shutdown) via a crafted TCP packet.
Open full assessment ↗ - CVE-2013-2808
Vulnerability Details
View details for CVE-2013-2808
Heap-based buffer overflow in Xper in Philips Xper Information Management Physiomonitoring 5 components, Xper Information Management Vascular Monitoring 5 components, and Xper Information Management servers and workstations for Flex Cardio products before XperConnect 1.5.4.053 SP2 allows remote attackers to execute arbitrary code via a crafted HTTP request to the Connect broker on TCP port 6000.
Open full assessment ↗ - CVE-2013-2807
Vulnerability Details
View details for CVE-2013-2807
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “Total Record Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size” that will cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
Open full assessment ↗ - CVE-2013-2806
Vulnerability Details
View details for CVE-2013-2806
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value, the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
Open full assessment ↗ - CVE-2013-2805
Vulnerability Details
View details for CVE-2013-2805
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 does not handle input correctly and results in a logic error if it receives a datagram with an incorrect value in the “Record Data Size” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to an oversized value, an attacker could cause an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to this vulnerability can be found at the following Rockwell Automation Security Advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
Open full assessment ↗ - CVE-2013-2804
Vulnerability Details
View details for CVE-2013-2804
The DNP Master Driver in Software Toolbox TOP Server before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line.
Open full assessment ↗ - CVE-2013-2803
Vulnerability Details
View details for CVE-2013-2803
ProSoft RadioLinx ControlScape before 6.00.040 uses a deficient PRNG algorithm and seeding strategy for passphrases, which makes it easier for remote attackers to obtain access via a brute-force attack.
Open full assessment ↗ - CVE-2013-2802
Vulnerability Details
View details for CVE-2013-2802
The universal protocol implementation in Sixnet UDR before 2.0 and RTU firmware before 4.8 allows remote attackers to execute arbitrary code; read, modify, or create files; or obtain file metadata via function opcodes.
Open full assessment ↗ - CVE-2013-2801
Vulnerability Details
View details for CVE-2013-2801
The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (instance shutdown and data-collection outage) via crafted C37.118 configuration packets that trigger an invalid read operation.
Open full assessment ↗ - CVE-2013-2800
Vulnerability Details
View details for CVE-2013-2800
The OSIsoft PI Interface for IEEE C37.118 before 1.0.6.158 allows remote attackers to cause a denial of service (memory consumption or memory corruption, instance shutdown, and data-collection outage) via crafted C37.118 configuration packets.
Open full assessment ↗ - CVE-2013-2798
Vulnerability Details
View details for CVE-2013-2798
Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line.
Open full assessment ↗ - CVE-2013-2796
Vulnerability Details
View details for CVE-2013-2796
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
Open full assessment ↗ - CVE-2013-2794
Vulnerability Details
View details for CVE-2013-2794
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line.
Open full assessment ↗ - CVE-2013-2793
Vulnerability Details
View details for CVE-2013-2793
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
Open full assessment ↗ - CVE-2013-2792
Vulnerability Details
View details for CVE-2013-2792
Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
Open full assessment ↗ - CVE-2013-2791
Vulnerability Details
View details for CVE-2013-2791
MatrikonOPC SCADA DNP3 OPC Server 1.2.0 allows remote attackers to cause a denial of service (master-station daemon crash) via a malformed DNP3 TCP packet from the IP address of an outstation.
Open full assessment ↗ - CVE-2013-2790
Vulnerability Details
View details for CVE-2013-2790
The master-station DNP3 driver before driver19.exe, and Beta2041.exe, in IOServer allows remote attackers to cause a denial of service (infinite loop) via crafted DNP3 packets to TCP port 20000.
Open full assessment ↗ - CVE-2013-2789
Vulnerability Details
View details for CVE-2013-2789
The Kepware DNP Master Driver for the KEPServerEX Communications Platform before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line.
Open full assessment ↗ - CVE-2013-2788
Vulnerability Details
View details for CVE-2013-2788
The DNP3 Slave service in SUBNET Solutions SubSTATION Server 2.7.0033 and 2.8.0106 allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors.
Open full assessment ↗ - CVE-2013-2787
Vulnerability Details
View details for CVE-2013-2787
Alstom e-terracontrol 3.5, 3.6, and 3.7 allows remote attackers to cause a denial of service (infinite loop) via crafted DNP3 packets.
Open full assessment ↗ - CVE-2013-2786
Vulnerability Details
View details for CVE-2013-2786
Alstom Grid MiCOM S1 Agile before 1.0.3 and Alstom Grid MiCOM S1 Studio use weak permissions for the MiCOM S1 %PROGRAMFILES% directory, which allows local users to gain privileges via a Trojan horse executable file.
Open full assessment ↗ - CVE-2013-2785
Vulnerability Details
View details for CVE-2013-2785
Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624.
Open full assessment ↗ - CVE-2013-2784
Vulnerability Details
View details for CVE-2013-2784
Triangle Research International (aka Tri) Nano-10 PLC devices with firmware before r81 use an incorrect algorithm for bounds checking of data in Modbus/TCP packets, which allows remote attackers to cause a denial of service (networking outage) via a crafted packet to TCP port 502.
Open full assessment ↗ - CVE-2013-2783
Vulnerability Details
View details for CVE-2013-2783
The DNP3 driver in IOServer drivers 1.0.19.0 allows remote attackers to cause a denial of service (infinite loop) or obtain unspecified control via crafted data to TCP port 20000.
Open full assessment ↗