- CVE-2013-0693
Vulnerability Details
View details for CVE-2013-0693
The kernel in ENEA OSE on the Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier performs network-beacon broadcasts, which allows remote attackers to obtain potentially sensitive information about device presence by listening for broadcast traffic.
Open full assessment ↗ - CVE-2013-0692
Vulnerability Details
View details for CVE-2013-0692
The kernel in ENEA OSE on the Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier allows remote attackers to execute arbitrary code by connecting to the debug service.
Open full assessment ↗ - CVE-2013-0689
Vulnerability Details
View details for CVE-2013-0689
The TFTP server on the Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier allows remote attackers to upload files and consequently execute arbitrary code via unspecified vectors.
Open full assessment ↗ - CVE-2013-0688
Vulnerability Details
View details for CVE-2013-0688
Cross-site scripting (XSS) vulnerability in Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, and 5.0- Portal allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Open full assessment ↗ - CVE-2013-0687
Vulnerability Details
View details for CVE-2013-0687
The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file.
Open full assessment ↗ - CVE-2013-0686
Vulnerability Details
View details for CVE-2013-0686
Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, and 5.0- Portal allows remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
Open full assessment ↗ - CVE-2013-0685
Vulnerability Details
View details for CVE-2013-0685
Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, and 5.0- Portal does not restrict unspecified size and amount values, which allows remote attackers to execute arbitrary code or cause a denial of service (resource consumption) via unknown vectors.
Open full assessment ↗ - CVE-2013-0684
Vulnerability Details
View details for CVE-2013-0684
SQL injection vulnerability in Invensys Wonderware Information Server (WIS) 4.0 SP1SP1, 4.5- Portal, and 5.0- Portal allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
Open full assessment ↗ - CVE-2013-0683
Vulnerability Details
View details for CVE-2013-0683
The DataSim and DataPid demonstration clients in Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC DataHub before 6.4.22, Cascade DataHub before 6.4.22 on Windows, and DataHub QuickTrend before 7.3.0 allow remote servers to cause a denial of service (incorrect pointer access and client crash) via malformed data in a formatted text command.
Open full assessment ↗ - CVE-2013-0682
Vulnerability Details
View details for CVE-2013-0682
Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC DataHub before 6.4.22, Cascade DataHub before 6.4.22 on Windows, and DataHub QuickTrend before 7.3.0 do not properly handle exceptions, which allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via malformed data in a formatted text command, leading to out-of-bounds access to (1) heap or (2) stack memory.
Open full assessment ↗ - CVE-2013-0681
Vulnerability Details
View details for CVE-2013-0681
Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC DataHub before 6.4.22, Cascade DataHub before 6.4.22 on Windows, and DataHub QuickTrend before 7.3.0 allow remote attackers to cause a denial of service (NULL pointer dereference and application crash) via malformed data in a formatted text command.
Open full assessment ↗ - CVE-2013-0680
Vulnerability Details
View details for CVE-2013-0680
Stack-based buffer overflow in the web server in Cogent Real-Time Systems Cogent DataHub before 7.3.0, OPC DataHub before 6.4.22, Cascade DataHub before 6.4.22 on Windows, and DataHub QuickTrend before 7.3.0 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via a long HTTP header.
Open full assessment ↗ - CVE-2013-0679
Vulnerability Details
View details for CVE-2013-0679
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
Open full assessment ↗ - CVE-2013-0678
Vulnerability Details
View details for CVE-2013-0678
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.
Open full assessment ↗ - CVE-2013-0677
Vulnerability Details
View details for CVE-2013-0677
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
Open full assessment ↗ - CVE-2013-0676
Vulnerability Details
View details for CVE-2013-0676
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
Open full assessment ↗ - CVE-2013-0675
Vulnerability Details
View details for CVE-2013-0675
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.
Open full assessment ↗ - CVE-2013-0674
Vulnerability Details
View details for CVE-2013-0674
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.
Open full assessment ↗ - CVE-2013-0673
Vulnerability Details
View details for CVE-2013-0673
Directory traversal vulnerability in the web interface in the Health Monitor service in MatrikonOPC A&E Historian 1.0.0.0 allows remote attackers to read and delete arbitrary files via a crafted URL.
Open full assessment ↗ - CVE-2013-0672
Vulnerability Details
View details for CVE-2013-0672
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.
Open full assessment ↗ - CVE-2013-0671
Vulnerability Details
View details for CVE-2013-0671
Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.
Open full assessment ↗ - CVE-2013-0670
Vulnerability Details
View details for CVE-2013-0670
CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.
Open full assessment ↗ - CVE-2013-0669
Vulnerability Details
View details for CVE-2013-0669
The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request.
Open full assessment ↗ - CVE-2013-0668
Vulnerability Details
View details for CVE-2013-0668
Multiple cross-site scripting (XSS) vulnerabilities in the HMI web application in Siemens WinCC (TIA Portal) 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL.