CVE 2014 Directory: Page 168
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
8,432 published records with identifiers assigned to 2014. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 168 of 352
- CVE-2014-5425
Vulnerability Details
View details for CVE-2014-5425
IOServer before Beta2112.exe allows remote attackers to cause a denial of service (out-of-bounds read and master entry consumption) via a null DNP3 header.
Open full assessment ↗ - CVE-2014-5424
Vulnerability Details
View details for CVE-2014-5424
Rockwell Automation Connected Components Workbench (CCW) before 7.00.00 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via an invalid property value to an ActiveX control that was built with an outdated compiler.
Open full assessment ↗ - CVE-2014-5423
Vulnerability Details
View details for CVE-2014-5423
CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 allows local users to obtain potentially sensitive information by reading a temporary (1) debugging file or (2) developer file.
Open full assessment ↗ - CVE-2014-5422
Vulnerability Details
View details for CVE-2014-5422
CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded service password, which makes it easier for remote attackers to obtain access via unspecified vectors.
Open full assessment ↗ - CVE-2014-5421
Vulnerability Details
View details for CVE-2014-5421
CareFusion Pyxis SupplyStation 8.1 with hardware test tool 1.0.16 and earlier has a hardcoded database password, which makes it easier for local users to gain privileges by leveraging cabinet access.
Open full assessment ↗ - CVE-2014-5420
Vulnerability Details
View details for CVE-2014-5420
CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded application password, which makes it easier for remote authenticated users to obtain application-file access via unspecified vectors.
Open full assessment ↗ - CVE-2014-5419
GE Multilink Use of Hard-coded Cryptographic Key
View details for CVE-2014-5419
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier use the same RSA private key across different customers' installations, which makes it easier for remote attackers to obtain the cleartext content of network traffic by reading this key from a firmware image and then sniffing the network.
Open full assessment ↗ - CVE-2014-5418
GE Multilink Uncontrolled Resource Consumption
View details for CVE-2014-5418
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets.
Open full assessment ↗ - CVE-2014-5417
Meinberg Radio Clocks LANTIME M-Series
View details for CVE-2014-5417
Cross-site scripting (XSS) vulnerability in Meinberg NTP Server firmware on LANTIME M-Series devices 6.15.019 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Open full assessment ↗ - CVE-2014-5415
Beckhoff Embedded PC Images and TwinCAT Components Exposed Dangerous Method or Function
View details for CVE-2014-5415
Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components might allow remote attackers to obtain access via the (1) Windows CE Remote Configuration Tool, (2) CE Remote Display service, or (3) TELNET service.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2014-5414
Beckhoff Embedded PC Images and TwinCAT Components Improper Restriction of Excessive Authentication Attempts
View details for CVE-2014-5414
Beckhoff Embedded PC images before 2014-10-22 and Automation Device Specification (ADS) TwinCAT components do not restrict the number of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2014-5413
Schneider Electric SCADA Expert ClearSCADA Cryptographic Issues
View details for CVE-2014-5413
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.
Open full assessment ↗ - CVE-2014-5412
Schneider Electric SCADA Expert ClearSCADA Improper Authentication
View details for CVE-2014-5412
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
Open full assessment ↗ - CVE-2014-5411
Schneider Electric SCADA Expert ClearSCADA Cross-site Scripting
View details for CVE-2014-5411
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
Open full assessment ↗ - CVE-2014-5410
Rockwell Automation Micrologix 1400 Improper Input Validation
View details for CVE-2014-5410
The DNP3 feature on Rockwell Automation Allen-Bradley MicroLogix 1400 1766-Lxxxxx A FRN controllers 7 and earlier and 1400 1766-Lxxxxx B FRN controllers before 15.001 allows remote attackers to cause a denial of service (process disruption) via malformed packets over (1) an Ethernet network or (2) a serial line.
Open full assessment ↗ - CVE-2014-5409
GE Hydran M2 Predictable Value Range from Previous Values
View details for CVE-2014-5409
The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values.
Open full assessment ↗ - CVE-2014-5408
Nordex NC2 Cross-site Scripting
View details for CVE-2014-5408
Cross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter.
Open full assessment ↗ - CVE-2014-5407
Schneider Electric VAMPSET Stack-based Buffer Overflow
View details for CVE-2014-5407
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
Open full assessment ↗ - CVE-2014-5406
Hospira LifeCare PCA Infusion System
View details for CVE-2014-5406
The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a (1) drug library, (2) software update, or (3) configuration change, which allows remote attackers to modify settings or medication data via packets on the (a) TELNET, (b) HTTP, (c) HTTPS, or (d) UPNP port. NOTE: this issue might overlap CVE-2015-3459.
Open full assessment ↗ - CVE-2014-5405
Hospira MedNet Use of Hard-coded Password
View details for CVE-2014-5405
Hospira MedNet before 6.1 uses a hardcoded cleartext password to control SQL database authorization, which allows remote authenticated users to bypass intended access restrictions by leveraging knowledge of this password.
Open full assessment ↗ - CVE-2014-5403
Hospira MedNet Use of Hard-coded Cryptographic Key
View details for CVE-2014-5403
Hospira MedNet before 6.1 uses hardcoded cryptographic keys for protection of data transmission from infusion pumps, which allows remote attackers to obtain sensitive information by sniffing the network.
Open full assessment ↗ - CVE-2014-5401
Hospira MedNet Code Injection
View details for CVE-2014-5401
Hospira MedNet software version 5.8 and prior uses vulnerable versions of the JBoss Enterprise Application Platform software that may allow unauthenticated users to execute arbitrary code on the target system. Hospira has developed a new version of the MedNet software, MedNet 6.1. Existing versions of MedNet can be upgraded to MedNet 6.1.
Open full assessment ↗ - CVE-2014-5400
Hospira MedNet Password in Configuration File
View details for CVE-2014-5400
The installation component in Hospira MedNet before 6.1 places cleartext credentials in configuration files, which allows local users to obtain sensitive information by reading a file.
Open full assessment ↗ - CVE-2014-5399
Schneider Electric Wonderware SQL Injection
View details for CVE-2014-5399
SQL injection vulnerability in Schneider Electric Wonderware Information Server (WIS) Portal 4.0 SP1 through 5.5 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
Open full assessment ↗