- CVE-2014-9204
Vulnerability Details
View details for CVE-2014-9204
Stack-based buffer overflow in OPCTest.exe in Rockwell Automation RSLinx Classic before 3.73.00 allows remote attackers to execute arbitrary code via a crafted CSV file.
Open full assessment ↗ - CVE-2014-9203
Vulnerability Details
View details for CVE-2014-9203
Buffer overflow in the Field Device Tool (FDT) Frame application in the HART Device Type Manager (DTM) library, as used in MACTek Bullet DTM 1.00.0, GE Vector DTM 1.00.0, GE SVi1000 Positioner DTM 1.00.0, GE SVI II AP Positioner DTM 2.00.1, and GE 12400 Level Transmitter DTM 1.00.0, allows remote attackers to cause a denial of service (DTM outage) via crafted packets.
Open full assessment ↗ - CVE-2014-9202
Vulnerability Details
View details for CVE-2014-9202
Multiple stack-based buffer overflows in an unspecified DLL file in Advantech WebAccess before 8.0_20150816 allow remote attackers to execute arbitrary code via a crafted file that triggers long string arguments to functions.
Open full assessment ↗ - CVE-2014-9201
Vulnerability Details
View details for CVE-2014-9201
Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital Tapchanger Control with firmware before D-0214V01.10.04, M-6283A Three Phase Digital Capacitor Bank Control with firmware before D-0346V03.00.02, M-6280A Digital Capacitor Bank Control with firmware before D-0254V03.05.05, and M-6280 Digital Capacitor Bank Control do not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.
Open full assessment ↗ - CVE-2014-9200
Schneider Electric Device Type Managers (DTMs) Stack-based Buffer Overflow
View details for CVE-2014-9200
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
Open full assessment ↗ - CVE-2014-9199
Clorius Controls A/S ISC SCADA Insecure Java Client Inadequate Encryption Strength
View details for CVE-2014-9199
The Clorius Controls Java web client before 01.00.0009g allows remote attackers to discover credentials by sniffing the network for cleartext-equivalent traffic.
Open full assessment ↗ - CVE-2014-9198
Schneider Electric ETG3000 FactoryCast HMI Gateway Use of Hard-coded Credentials
View details for CVE-2014-9198
The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
Open full assessment ↗ - CVE-2014-9197
Schneider Electric ETG3000 FactoryCast HMI Gateway Missing Authentication for Critical Function
View details for CVE-2014-9197
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.
Open full assessment ↗ - CVE-2014-9196
Eaton’s Cooper Power Series Form 6 Control and Idea/IdeaPlus Relays with Ethernet
View details for CVE-2014-9196
Eaton Cooper Power Systems ProView 4.0 and 5.0 before 5.0 11 on Form 6 controls and Idea and IdeaPLUS relays generates TCP initial sequence number (ISN) values linearly, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.
Open full assessment ↗ - CVE-2014-9195
Phoenix Contact Software ProConOs and MultiProg Missing Authentication for Critical Function
View details for CVE-2014-9195
Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant traffic.
Open full assessment ↗ - CVE-2014-9194
Arbiter Systems 1094B GPS Clock Insufficient Verification of Data Authenticity
View details for CVE-2014-9194
Arbiter 1094B GPS Substation Clock allows remote attackers to cause a denial of service (disruption) via crafted radio transmissions that spoof GPS satellite broadcasts.
Open full assessment ↗ - CVE-2014-9193
Innominate mGuard Improper Privilege Management
View details for CVE-2014-9193
Innominate mGuard with firmware before 7.6.6 and 8.x before 8.1.4 allows remote authenticated admins to obtain root privileges by changing a PPP configuration setting.
Open full assessment ↗ - CVE-2014-9192
Trihedral Engineering Limited VTScada Integer Overflow
View details for CVE-2014-9192
Integer overflow in Trihedral Engineering VTScada (formerly VTS) 6.5 through 9.x before 9.1.20, 10.x before 10.2.22, and 11.x before 11.1.07 allows remote attackers to cause a denial of service (server crash) via a crafted request, which triggers a large memory allocation.
Open full assessment ↗ - CVE-2014-9191
Vulnerability Details
View details for CVE-2014-9191
The CodeWrights HART Device Type Manager (DTM) library in Emerson HART DTM before 1.4.181 allows physically proximate attackers to cause a denial of service (DTM outage and FDT Frame application hang) by transmitting crafted response packets on the 4-20 mA current loop.
Open full assessment ↗ - CVE-2014-9190
Schneider Electric Wonderware InTouch Access Anywhere Server Buffer Overflow
View details for CVE-2014-9190
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.
Open full assessment ↗ - CVE-2014-9189
Vulnerability Details
View details for CVE-2014-9189
Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
Open full assessment ↗ - CVE-2014-9188
Schneider Electric ProClima Command Injection
View details for CVE-2014-9188
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
Open full assessment ↗ - CVE-2014-9187
Vulnerability Details
View details for CVE-2014-9187
Multiple heap-based buffer overflow vulnerabilities exist in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules, which could lead to possible remote code execution or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
Open full assessment ↗ - CVE-2014-9186
Vulnerability Details
View details for CVE-2014-9186
A file inclusion vulnerability exists in the confd.exe module in Honeywell Experion PKS R40x before R400.6, R41x before R410.6, and R43x before R430.2, which could lead to accepting an arbitrary file into the function, and potential information disclosure or remote code execution. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
Open full assessment ↗ - CVE-2014-9185
Vulnerability Details
View details for CVE-2014-9185
Static code injection vulnerability in install.php in Morfy CMS 1.05 allows remote authenticated users to inject arbitrary PHP code into config.php via the site_url parameter.
Open full assessment ↗ - CVE-2014-9184
Vulnerability Details
View details for CVE-2014-9184
ZTE ZXDSL 831CII allows remote attackers to bypass authentication via a direct request to (1) main.cgi, (2) adminpasswd.cgi, (3) userpasswd.cgi, (4) upload.cgi, (5) conprocess.cgi, or (6) connect.cgi.
Open full assessment ↗ - CVE-2014-9183
Vulnerability Details
View details for CVE-2014-9183
ZTE ZXDSL 831CII has a default password of admin for the admin account, which allows remote attackers to gain administrator privileges.
Open full assessment ↗ - CVE-2014-9182
Vulnerability Details
View details for CVE-2014-9182
models/comment.php in Anchor CMS 0.9.2 and earlier allows remote attackers to inject arbitrary headers into mail messages via a crafted Host: header.
Open full assessment ↗ - CVE-2014-9181
Vulnerability Details
View details for CVE-2014-9181
Multiple directory traversal vulnerabilities in Plex Media Server before 0.9.9.3 allow remote attackers to read arbitrary files via a .. (dot dot) in the URI to (1) manage/ or (2) web/ or remote authenticated users to read arbitrary files via a .. (dot dot) in the URI to resources/.
Open full assessment ↗