CVE 2015 Directory: Page 112
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
8,116 published records with identifiers assigned to 2015. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 112 of 339
- CVE-2015-6492
Vulnerability Details
View details for CVE-2015-6492
Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote attackers to cause a denial of service (memory corruption and device crash) via a crafted HTTP request.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2015-6491
Vulnerability Details
View details for CVE-2015-6491
Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticated users to insert the content of an arbitrary file into a FRAME element via unspecified vectors.
Open full assessment ↗ - CVE-2015-6490
Vulnerability Details
View details for CVE-2015-6490
Stack-based buffer overflow on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices through B FRN 15.003 allows remote attackers to execute arbitrary code via unspecified vectors.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2015-6488
Vulnerability Details
View details for CVE-2015-6488
Cross-site scripting (XSS) vulnerability in the web server on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Open full assessment ↗ - CVE-2015-6486
Vulnerability Details
View details for CVE-2015-6486
SQL injection vulnerability on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote authenticated users to execute arbitrary SQL commands via unspecified vectors.
Open full assessment ↗ - CVE-2015-6485
Vulnerability Details
View details for CVE-2015-6485
Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet.
Open full assessment ↗ - CVE-2015-6484
Vulnerability Details
View details for CVE-2015-6484
3S-Smart CODESYS Gateway Server before 2.3.9.48 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via a crafted (1) GET or (2) POST request.
Open full assessment ↗ - CVE-2015-6482
Vulnerability Details
View details for CVE-2015-6482
Runtime Toolkit before 2.4.7.48 in 3S-Smart CODESYS before 2.3.9.48 allows remote attackers to cause a denial of service (NULL pointer dereference and application crash) via a crafted request.
Open full assessment ↗ - CVE-2015-6481
Vulnerability Details
View details for CVE-2015-6481
The login function in the RequestController class in Moxa OnCell Central Manager before 2.2 has a hardcoded root password, which allows remote attackers to obtain administrative access via a login session.
Open full assessment ↗ - CVE-2015-6480
Vulnerability Details
View details for CVE-2015-6480
The MessageBrokerServlet servlet in Moxa OnCell Central Manager before 2.2 does not require authentication, which allows remote attackers to obtain administrative access via a command, as demonstrated by the addUserAndGroup action.
Open full assessment ↗ - CVE-2015-6479
Vulnerability Details
View details for CVE-2015-6479
ACEmanager in Sierra Wireless ALEOS 4.4.2 and earlier on ES440, ES450, GX400, GX440, GX450, and LS300 devices allows remote attackers to read the filteredlogs.txt file, and consequently discover potentially sensitive boot-sequence information, via unspecified vectors.
Open full assessment ↗ - CVE-2015-6478
Vulnerability Details
View details for CVE-2015-6478
Unitronics VisiLogic OPLC IDE before 9.8.02 does not properly restrict access to ActiveX controls, which allows remote attackers to have an unspecified impact via a crafted web site.
Open full assessment ↗ - CVE-2015-6477
Vulnerability Details
View details for CVE-2015-6477
Multiple cross-site scripting (XSS) vulnerabilities in the Wind Farm Portal application in Nordex Control 2 (NC2) SCADA 16 and earlier allow remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2015-6476
Vulnerability Details
View details for CVE-2015-6476
Advantech EKI-122x-BE devices with firmware before 1.65, EKI-132x devices with firmware before 1.98, and EKI-136x devices with firmware before 1.27 have hardcoded SSH keys, which makes it easier for remote attackers to obtain access via an SSH session.
Open full assessment ↗ - CVE-2015-6475
Vulnerability Details
View details for CVE-2015-6475
Multiple cross-site scripting (XSS) vulnerabilities in IBC Solar ServeMaster TLP+ and Danfoss TLX Pro+ allow remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Open full assessment ↗ - CVE-2015-6474
Vulnerability Details
View details for CVE-2015-6474
IBC Solar ServeMaster TLP+ and Danfoss TLX Pro+ allow remote attackers to discover cleartext passwords by reading HTML source code.
Open full assessment ↗ - CVE-2015-6473
Vulnerability Details
View details for CVE-2015-6473
WAGO IO 750-849 01.01.27 and WAGO IO 750-881 01.02.05 do not contain privilege separation.
Open full assessment ↗ - CVE-2015-6472
Vulnerability Details
View details for CVE-2015-6472
WAGO IO 750-849 01.01.27 and 01.02.05, WAGO IO 750-881, and WAGO IO 758-870 have weak credential management.
Open full assessment ↗ - CVE-2015-6471
Vulnerability Details
View details for CVE-2015-6471
Eaton Cooper Power Systems ProView 4.x and 5.x before 5.1 on Form 6 controls and Idea and IdeaPLUS relays does not properly initialize padding fields in Ethernet packets, which allows remote attackers to obtain sensitive information by reading packet data.
Open full assessment ↗ - CVE-2015-6470
Vulnerability Details
View details for CVE-2015-6470
Resource Data Management Data Manager before 2.2 allows remote authenticated users to modify arbitrary passwords via unspecified vectors.
Open full assessment ↗ - CVE-2015-6469
Vulnerability Details
View details for CVE-2015-6469
The interpreter in IBC Solar ServeMaster TLP+ and Danfoss TLX Pro+ allows remote attackers to discover script source code via unspecified vectors.
Open full assessment ↗ - CVE-2015-6468
Vulnerability Details
View details for CVE-2015-6468
Cross-site request forgery (CSRF) vulnerability in Resource Data Management Data Manager before 2.2 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.
Open full assessment ↗ - CVE-2015-6467
Vulnerability Details
View details for CVE-2015-6467
Advantech WebAccess before 8.1 allows remote attackers to execute arbitrary code via vectors involving a browser plugin.
Open full assessment ↗ - CVE-2015-6466
Vulnerability Details
View details for CVE-2015-6466
Cross-site scripting (XSS) vulnerability in the Diagnosis Ping feature in the administrative web interface on Moxa EDS-405A and EDS-408A switches with firmware before 3.6 allows remote attackers to inject arbitrary web script or HTML via an unspecified field.
Open full assessment ↗