- CVE-2015-1003
Vulnerability Details
View details for CVE-2015-1003
Directory traversal vulnerability in IniNet embeddedWebServer (aka eWebServer) before 2.02 allows remote attackers to read arbitrary files via a crafted pathname.
Open full assessment ↗ - CVE-2015-1002
Vulnerability Details
View details for CVE-2015-1002
IniNet embeddedWebServer (aka eWebServer) before 2.02 mishandles URL encoding, which allows remote attackers to write to or delete files via a crafted string.
Open full assessment ↗ - CVE-2015-1001
Vulnerability Details
View details for CVE-2015-1001
Multiple stack-based buffer overflows in IniNet embeddedWebServer (aka eWebServer) before 2.02 allow remote attackers to execute arbitrary code via a long field in an HTTP request.
Open full assessment ↗ - CVE-2015-1000
Vulnerability Details
View details for CVE-2015-1000
Stack-based buffer overflow in the OpenForIPCamTest method in the RTSPVIDEO.rtspvideoCtrl.1 (aka SStreamVideo) ActiveX control in Moxa SoftCMS before 1.3 allows remote attackers to execute arbitrary code via the StrRtspPath parameter.
Open full assessment ↗ - CVE-2015-0999
Vulnerability Details
View details for CVE-2015-0999
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
Open full assessment ↗ - CVE-2015-0998
Vulnerability Details
View details for CVE-2015-0998
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.
Open full assessment ↗ - CVE-2015-0997
Vulnerability Details
View details for CVE-2015-0997
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack.
Open full assessment ↗ - CVE-2015-0996
Vulnerability Details
View details for CVE-2015-0996
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.
Open full assessment ↗ - CVE-2015-0995
Vulnerability Details
View details for CVE-2015-0995
Inductive Automation Ignition 7.7.2 uses MD5 password hashes, which makes it easier for context-dependent attackers to obtain access via a brute-force attack.
Open full assessment ↗ - CVE-2015-0994
Vulnerability Details
View details for CVE-2015-0994
Inductive Automation Ignition 7.7.2 allows remote authenticated users to bypass a brute-force protection mechanism by using different session ID values in a series of HTTP requests.
Open full assessment ↗ - CVE-2015-0993
Vulnerability Details
View details for CVE-2015-0993
Inductive Automation Ignition 7.7.2 does not terminate a session upon a logout action, which allows remote attackers to bypass intended access restrictions by leveraging an unattended workstation.
Open full assessment ↗ - CVE-2015-0992
Vulnerability Details
View details for CVE-2015-0992
Inductive Automation Ignition 7.7.2 stores cleartext OPC Server credentials, which allows local users to obtain sensitive information via unspecified vectors.
Open full assessment ↗ - CVE-2015-0991
Vulnerability Details
View details for CVE-2015-0991
Inductive Automation Ignition 7.7.2 allows remote attackers to obtain sensitive information by reading an error message about an unhandled exception, as demonstrated by pathname information.
Open full assessment ↗ - CVE-2015-0990
Vulnerability Details
View details for CVE-2015-0990
Untrusted search path vulnerability in Ecava IntegraXor SCADA Server before 4.2.4488 allows local users to gain privileges via a renamed DLL in the default install directory.
Open full assessment ↗ - CVE-2015-0989
Vulnerability Details
View details for CVE-2015-0989
PACTware 4.1 SP3 allows remote attackers to cause a denial of service (application crash) via a crafted file that triggers an internal error.
Open full assessment ↗ - CVE-2015-0988
Vulnerability Details
View details for CVE-2015-0988
Omron CX-One CX-Programmer before 9.6 uses a reversible format for password storage in project source-code files, which makes it easier for local users to obtain sensitive information by reading a file.
Open full assessment ↗ - CVE-2015-0987
Vulnerability Details
View details for CVE-2015-0987
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2015-0986
Vulnerability Details
View details for CVE-2015-0986
Multiple stack-based buffer overflows in Moxa VPort ActiveX SDK Plus before 2.8 allow remote attackers to insert assembly-code lines via vectors involving a regkey (1) set or (2) get command.
Open full assessment ↗ - CVE-2015-0985
Vulnerability Details
View details for CVE-2015-0985
Cross-site request forgery (CSRF) vulnerability in XZERES 442SR OS on 442SR wind turbines allows remote attackers to hijack the authentication of admins for requests that modify the default user's password via a GET request.
Open full assessment ↗ - CVE-2015-0984
Vulnerability Details
View details for CVE-2015-0984
Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C500 300 I/O, XL1000C1000 600 I/O, XL1000C50U 52 I/O UUKL, XL1000C100U 104 I/O UUKL, XL1000C500U 300 I/O UUKL, and XL1000C1000U 600 I/O UUKL controllers before 2.04.01 allows remote attackers to read files under the web root, and consequently obtain administrative login access, via a crafted pathname.
Open full assessment ↗ - CVE-2015-0982
Vulnerability Details
View details for CVE-2015-0982
Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.
Open full assessment ↗ - CVE-2015-0981
Vulnerability Details
View details for CVE-2015-0981
The SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to bypass authentication and read or write to arbitrary database fields via unspecified vectors.
Open full assessment ↗ - CVE-2015-0980
Vulnerability Details
View details for CVE-2015-0980
Format string vulnerability in BACnOPCServer.exe in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via format string specifiers in a request.
Open full assessment ↗ - CVE-2015-0979
Vulnerability Details
View details for CVE-2015-0979
Heap-based buffer overflow in the SOAP web interface in SCADA Engine BACnet OPC Server before 2.1.371.24 allows remote attackers to execute arbitrary code via a crafted packet.