- CVE-2016-5828
Vulnerability Details
View details for CVE-2016-5828
The start_thread function in arch/powerpc/kernel/process.c in the Linux kernel through 4.6.3 on powerpc platforms mishandles transactional state, which allows local users to cause a denial of service (invalid process state or TM Bad Thing exception, and system crash) or possibly have unspecified other impact by starting and suspending a transaction before an exec system call.
Open full assessment ↗ - CVE-2016-5827
Vulnerability Details
View details for CVE-2016-5827
The icaltime_from_string function in libical 0.47 and 1.0 allows remote attackers to cause a denial of service (out-of-bounds heap read) via a crafted string to the icalparser_parse_string function.
Open full assessment ↗ - CVE-2016-5826
Vulnerability Details
View details for CVE-2016-5826
The parser_get_next_char function in libical 0.47 and 1.0 allows remote attackers to cause a denial of service (out-of-bounds heap read) by crafting a string to the icalparser_parse_string function.
Open full assessment ↗ - CVE-2016-5825
Vulnerability Details
View details for CVE-2016-5825
The icalparser_parse_string function in libical 0.47 and 1.0 allows remote attackers to cause a denial of service (out-of-bounds heap read) via a crafted ics file.
Open full assessment ↗ - CVE-2016-5824
Vulnerability Details
View details for CVE-2016-5824
libical 1.0 allows remote attackers to cause a denial of service (use-after-free) via a crafted ics file.
Open full assessment ↗ - CVE-2016-5823
Vulnerability Details
View details for CVE-2016-5823
The icalproperty_new_clone function in libical 0.47 and 1.0 allows remote attackers to cause a denial of service (use-after-free) via a crafted ics file.
Open full assessment ↗ - CVE-2016-5822
Vulnerability Details
View details for CVE-2016-5822
Huawei Oceanstor 5800 before V300R002C10SPC100 allows remote attackers to cause a denial of service (CPU consumption) via a large number of crafted HTTP packets.
Open full assessment ↗ - CVE-2016-5821
Vulnerability Details
View details for CVE-2016-5821
Huawei HiSuite before 4.0.4.204_ove (Out of China) and before 4.0.4.301 (China) use a weak ACL (FILE_WRITE_DATA for BUILTIN\Users) for the HiSuite service directory, which allows local users to gain SYSTEM privileges via a Trojan horse (1) SspiCli.dll or (2) USERENV.dll file or possibly other unspecified DLL files.
Open full assessment ↗ - CVE-2016-5819
Vulnerability Details
View details for CVE-2016-5819
Moxa G3100V2 Series, editions prior to Version 2.8, and OnCell G3111/G3151/G3211/G3251 Series, editions prior to Version 1.7 allows a reflected cross-site scripting attack which may allow an attacker to execute arbitrary script code in the user’s browser within the trust relationship between their browser and the server.
Open full assessment ↗ - CVE-2016-5818
Vulnerability Details
View details for CVE-2016-5818
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device.
Open full assessment ↗ - CVE-2016-5817
Vulnerability Details
View details for CVE-2016-5817
SQL injection vulnerability in news pages in Cargotec Navis WebAccess before 2016-08-10 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
Open full assessment ↗ - CVE-2016-5816
Vulnerability Details
View details for CVE-2016-5816
A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source.
Open full assessment ↗ - CVE-2016-5815
Vulnerability Details
View details for CVE-2016-5815
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.
Open full assessment ↗ - CVE-2016-5814
Vulnerability Details
View details for CVE-2016-5814
Buffer overflow in Rockwell Automation RSLogix Micro Starter Lite, RSLogix Micro Developer, RSLogix 500 Starter Edition, RSLogix 500 Standard Edition, and RSLogix 500 Professional Edition allows remote attackers to execute arbitrary code via a crafted RSS project file.
Open full assessment ↗ - CVE-2016-5813
Vulnerability Details
View details for CVE-2016-5813
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. When a specific URL to an image is accessed, the downloaded image carries with it source code used in the web server (INFORMATION EXPOSURE).
Open full assessment ↗ - CVE-2016-5812
Vulnerability Details
View details for CVE-2016-5812
Moxa OnCell G3100V2 devices before 2.8 and G3111, G3151, G3211, and G3251 devices before 1.7 use cleartext password storage, which makes it easier for local users to obtain sensitive information by reading a configuration file.
Open full assessment ↗ - CVE-2016-5811
Vulnerability Details
View details for CVE-2016-5811
An issue was discovered in Visonic PowerLink2, all versions prior to October 2016 firmware release. User controlled input is not neutralized prior to being placed in web page output (CROSS-SITE SCRIPTING).
Open full assessment ↗ - CVE-2016-5810
Vulnerability Details
View details for CVE-2016-5810
upAdminPg.asp in Advantech WebAccess before 8.1_20160519 allows remote authenticated administrators to obtain sensitive password information via unspecified vectors.
Open full assessment ↗ - CVE-2016-5809
Vulnerability Details
View details for CVE-2016-5809
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
Open full assessment ↗ - CVE-2016-5807
Vulnerability Details
View details for CVE-2016-5807
Tollgrade LightHouse SMS before 5.1 patch 3 allows remote authenticated users to bypass an intended administrative-authentication requirement, and read or change parameter values, via a direct request.
Open full assessment ↗ - CVE-2016-5805
Vulnerability Details
View details for CVE-2016-5805
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to2.10.10. There are multiple instances of heap-based buffer overflows that may allow malicious files to cause the execution of arbitrary code or a denial of service.
Open full assessment ↗ - CVE-2016-5804
Vulnerability Details
View details for CVE-2016-5804
Moxa MGate MB3180 before 1.8, MGate MB3280 before 2.7, MGate MB3480 before 2.6, MGate MB3170 before 2.5, and MGate MB3270 before 2.7 use weak encryption, which allows remote attackers to bypass authentication via a brute-force series of guesses for a parameter value.
Open full assessment ↗ - CVE-2016-5803
Vulnerability Details
View details for CVE-2016-5803
An issue was discovered in CA Unified Infrastructure Management Version 8.47 and earlier. The Unified Infrastructure Management software uses external input to construct a pathname that should be within a restricted directory, but it does not properly neutralize sequences such as ".." that can resolve to a location that is outside of that directory.
Open full assessment ↗ - CVE-2016-5802
Vulnerability Details
View details for CVE-2016-5802
An issue was discovered in Delta Electronics WPLSoft, Versions prior to V2.42.11, ISPSoft, Versions prior to 3.02.11, and PMSoft, Versions prior to 2.10.10. Multiple instances of out-of-bounds write conditions may allow malicious files to be read and executed by the affected software.
Open full assessment ↗