CVE 2016 Directory: Page 229
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
9,376 published records with identifiers assigned to 2016. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 229 of 391
- CVE-2016-4535
Vulnerability Details
View details for CVE-2016-4535
Integer signedness error in the AV engine before DAT 8145, as used in McAfee LiveSafe 14.0, allows remote attackers to cause a denial of service (memory corruption and crash) via a crafted packed executable.
Open full assessment ↗ - CVE-2016-4534
Vulnerability Details
View details for CVE-2016-4534
The McAfee VirusScan Console (mcconsol.exe) in McAfee VirusScan Enterprise 8.8.0 before Hotfix 1123565 (8.8.0.1546) on Windows allows local administrators to bypass intended self-protection rules and unlock the console window by closing registry handles.
Open full assessment ↗ - CVE-2016-4533
Vulnerability Details
View details for CVE-2016-4533
Heap-based buffer overflow in WECON LeviStudio allows remote attackers to execute arbitrary code via a crafted file.
Open full assessment ↗ - CVE-2016-4532
Vulnerability Details
View details for CVE-2016-4532
Directory traversal vulnerability in the WAP interface in Trihedral VTScada (formerly VTS) 8.x through 11.x before 11.2.02 allows remote attackers to read arbitrary files via a crafted pathname.
Open full assessment ↗ - CVE-2016-4531
Vulnerability Details
View details for CVE-2016-4531
Rockwell Automation FactoryTalk EnergyMetrix before 2.20.00 does not invalidate credentials upon a logout action, which makes it easier for remote attackers to obtain access by leveraging an unattended workstation.
Open full assessment ↗ - CVE-2016-4530
Vulnerability Details
View details for CVE-2016-4530
OSIsoft PI SQL Data Access Server (aka OLE DB) 2016 1.5 allows remote authenticated users to cause a denial of service (service outage and data loss) via a message.
Open full assessment ↗ - CVE-2016-4529
Vulnerability Details
View details for CVE-2016-4529
An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag.
Open full assessment ↗ - CVE-2016-4528
Vulnerability Details
View details for CVE-2016-4528
Buffer overflow in Advantech WebAccess before 8.1_20160519 allows local users to cause a denial of service via a crafted DLL file.
Open full assessment ↗ - CVE-2016-4527
Vulnerability Details
View details for CVE-2016-4527
ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors.
Open full assessment ↗ - CVE-2016-4526
Vulnerability Details
View details for CVE-2016-4526
ABB DataManagerPro 1.x before 1.7.1 allows local users to gain privileges by replacing a DLL file in the package directory.
Open full assessment ↗ - CVE-2016-4525
Vulnerability Details
View details for CVE-2016-4525
Unspecified ActiveX controls in Advantech WebAccess before 8.1_20160519 allow remote authenticated users to obtain sensitive information or modify data via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag.
Open full assessment ↗ - CVE-2016-4524
Vulnerability Details
View details for CVE-2016-4524
ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors.
Open full assessment ↗ - CVE-2016-4523
Vulnerability Details
View details for CVE-2016-4523
The WAP interface in Trihedral VTScada (formerly VTS) 8.x through 11.x before 11.2.02 allows remote attackers to cause a denial of service (out-of-bounds read and application crash) via unspecified vectors.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2016-4522
Vulnerability Details
View details for CVE-2016-4522
SQL injection vulnerability in Rockwell Automation FactoryTalk EnergyMetrix before 2.20.00 allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
Open full assessment ↗ - CVE-2016-4521
Vulnerability Details
View details for CVE-2016-4521
Sixnet BT-5xxx and BT-6xxx M2M devices before 3.8.21 and 3.9.x before 3.9.8 have hardcoded credentials, which allows remote attackers to obtain access via unspecified vectors.
Open full assessment ↗ - CVE-2016-4520
Vulnerability Details
View details for CVE-2016-4520
Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors.
Open full assessment ↗ - CVE-2016-4519
Vulnerability Details
View details for CVE-2016-4519
Stack-based buffer overflow in Unitronics VisiLogic OPLC IDE before 9.8.30 allows remote attackers to execute arbitrary code via a crafted filename field in a ZIP archive in a vlp file.
Open full assessment ↗ - CVE-2016-4518
Vulnerability Details
View details for CVE-2016-4518
OSIsoft PI AF Server before 2016 2.8.0 allows remote authenticated users to cause a denial of service (service outage) via a message.
Open full assessment ↗ - CVE-2016-4516
Vulnerability Details
View details for CVE-2016-4516
ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors.
Open full assessment ↗ - CVE-2016-4514
Vulnerability Details
View details for CVE-2016-4514
Moxa PT-7728 devices with software 3.4 build 15081113 allow remote authenticated users to change the configuration via vectors involving a local proxy.
Open full assessment ↗ - CVE-2016-4513
Vulnerability Details
View details for CVE-2016-4513
Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Open full assessment ↗ - CVE-2016-4512
Vulnerability Details
View details for CVE-2016-4512
Stack-based buffer overflow in ELCSimulator in Eaton ELCSoft 2.4.01 and earlier allows remote attackers to execute arbitrary code via a long packet.
Open full assessment ↗ - CVE-2016-4511
Vulnerability Details
View details for CVE-2016-4511
ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file.
Open full assessment ↗ - CVE-2016-4510
Vulnerability Details
View details for CVE-2016-4510
The WAP interface in Trihedral VTScada (formerly VTS) 8.x through 11.x before 11.2.02 allows remote attackers to bypass authentication and read arbitrary files via unspecified vectors.
Open full assessment ↗