- CVE-2017-14023
Vulnerability Details
View details for CVE-2017-14023
An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface.
Open full assessment ↗ - CVE-2017-14022
Vulnerability Details
View details for CVE-2017-14022
An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.
Open full assessment ↗ - CVE-2017-14021
Vulnerability Details
View details for CVE-2017-14021
A Use of Hard-coded Cryptographic Key issue was discovered in Korenix JetNet JetNet5018G version 1.4, JetNet5310G version 1.4a, JetNet5428G-2G-2FX version 1.4, JetNet5628G-R version 1.4, JetNet5628G version 1.4, JetNet5728G-24P version 1.4, JetNet5828G version 1.1d, JetNet6710G-HVDC version 1.1e, and JetNet6710G version 1.1. An attacker may gain access to hard-coded certificates and private keys allowing the attacker to perform man-in-the-middle attacks.
Open full assessment ↗ - CVE-2017-14020
Vulnerability Details
View details for CVE-2017-14020
In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.30 and prior; C-More Micro (Part Number EA-PGMSW) Versions 4.20.01.0 and prior; Do-more Designer Software (Part Number DM-PGMSW) Versions 2.0.3 and prior; GS Drives Configuration Software (Part Number GSOFT) Versions 4.0.6 and prior; SL-SOFT SOLO Temperature Controller Configuration Software (Part Number SL-SOFT) Versions 1.1.0.5 and prior; and DirectSOFT Programming Software Versions 6.1 and prior, an uncontrolled search path element (DLL Hijacking) vulnerability has been identified. To exploit this vulnerability, an attacker could rename a malicious DLL to meet the criteria of the application, and the application would not verify that the DLL is correct. Once loaded by the application, the DLL could run malicious code at the privilege level of the application.
Open full assessment ↗ - CVE-2017-14019
Vulnerability Details
View details for CVE-2017-14019
An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate his or her privileges.
Open full assessment ↗ - CVE-2017-14018
Vulnerability Details
View details for CVE-2017-14018
An improper authentication issue was discovered in Johnson & Johnson Ethicon Endo-Surgery Generator Gen11, all versions released before November 29, 2017. The security authentication mechanism used between the Ethicon Endo-Surgery Generator Gen11 and single-patient use products can be bypassed, allowing for unauthorized devices to be connected to the generator, which could result in a loss of integrity or availability.
Open full assessment ↗ - CVE-2017-14017
Vulnerability Details
View details for CVE-2017-14017
An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file.
Open full assessment ↗ - CVE-2017-14016
Vulnerability Details
View details for CVE-2017-14016
A Stack-based Buffer Overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. The application lacks proper validation of the length of user-supplied data prior to copying it to a stack-based buffer, which could allow an attacker to execute arbitrary code under the context of the process.
Open full assessment ↗ - CVE-2017-14014
Vulnerability Details
View details for CVE-2017-14014
Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.
Open full assessment ↗ - CVE-2017-14013
Vulnerability Details
View details for CVE-2017-14013
A Client-Side Enforcement of Server-Side Security issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The log out function in the application removes the user's session only on the client side. This may allow an attacker to bypass protection mechanisms, gain privileges, or assume the identity of an authenticated user.
Open full assessment ↗ - CVE-2017-14012
Vulnerability Details
View details for CVE-2017-14012
Boston Scientific ZOOM LATITUDE PRM Model 3120 does not encrypt PHI at rest. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.
Open full assessment ↗ - CVE-2017-14011
Vulnerability Details
View details for CVE-2017-14011
A Cross-Site Request Forgery issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The application does not sufficiently verify requests, making it susceptible to cross-site request forgery. This may allow an attacker to execute unauthorized code, resulting in changes to the configuration of the device.
Open full assessment ↗ - CVE-2017-14010
Vulnerability Details
View details for CVE-2017-14010
In SpiderControl MicroBrowser Windows XP, Vista 7, 8 and 10, Versions 1.6.30.144 and prior, an uncontrolled search path element vulnerability has been identified which could be exploited by placing a specially crafted DLL file in the search path. If the malicious DLL is loaded prior to the valid DLL, an attacker could execute arbitrary code on the system.
Open full assessment ↗ - CVE-2017-14009
Vulnerability Details
View details for CVE-2017-14009
An Information Exposure issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When an authenticated user uses the Change Password feature on the application, the current password for the user is specified in plaintext. This may allow an attacker who has been authenticated to gain access to the password.
Open full assessment ↗ - CVE-2017-14008
Vulnerability Details
View details for CVE-2017-14008
GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Open full assessment ↗ - CVE-2017-14007
Vulnerability Details
View details for CVE-2017-14007
An Insufficient Session Expiration issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The user's session is available for an extended period beyond the last activity, allowing an attacker to reuse an old session for authorization.
Open full assessment ↗ - CVE-2017-14006
Vulnerability Details
View details for CVE-2017-14006
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Open full assessment ↗ - CVE-2017-14005
Vulnerability Details
View details for CVE-2017-14005
An Unverified Password Change issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When setting a new password for a user, the application does not require the user to know the original password. An attacker who is authenticated could change a user's password, enabling future access and possible configuration changes.
Open full assessment ↗ - CVE-2017-14004
Vulnerability Details
View details for CVE-2017-14004
GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Open full assessment ↗ - CVE-2017-14003
Vulnerability Details
View details for CVE-2017-14003
An Authentication Bypass by Spoofing issue was discovered in LAVA Ether-Serial Link (ESL) running firmware versions 6.01.00/29.03.2007 and prior versions. An improper authentication vulnerability has been identified, which, if exploited, would allow an attacker with the same IP address to bypass authentication by accessing a specific uniform resource locator.
Open full assessment ↗ - CVE-2017-14002
Vulnerability Details
View details for CVE-2017-14002
GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Open full assessment ↗ - CVE-2017-14001
Vulnerability Details
View details for CVE-2017-14001
An Improper Neutralization of Special Elements used in an OS Command issue was discovered in Digium Asterisk GUI 2.1.0 and prior. An OS command injection vulnerability has been identified that may allow the execution of arbitrary code on the system through the inclusion of OS commands in the URL request of the program.
Open full assessment ↗ - CVE-2017-14000
Vulnerability Details
View details for CVE-2017-14000
An Improper Authentication issue was discovered in Ctek SkyRouter Series 4200 and 4400, all versions prior to V6.00.11. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the application without authenticating.
Open full assessment ↗ - CVE-2017-13999
Vulnerability Details
View details for CVE-2017-13999
A Stack-based Buffer Overflow issue was discovered in WECON LEVI Studio HMI Editor v1.8.1 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified in which the application does not verify string size before copying to memory; the attacker may then be able to crash the application or run arbitrary code.
Open full assessment ↗