- CVE-2017-12732
Vulnerability Details
View details for CVE-2017-12732
A Stack-based Buffer Overflow issue was discovered in GE CIMPLICITY Versions 9.0 and prior. A function reads a packet to indicate the next packet length. The next packet length is not verified, allowing a buffer overwrite that could lead to an arbitrary remote code execution.
Open full assessment ↗ - CVE-2017-12731
Vulnerability Details
View details for CVE-2017-12731
A SQL Injection issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. The application is vulnerable to injection of malicious SQL queries via the input from the client.
Open full assessment ↗ - CVE-2017-12730
Vulnerability Details
View details for CVE-2017-12730
An Unquoted Search Path issue was discovered in mySCADA myPRO Versions 7.0.26 and prior. Application services utilize unquoted search path elements, which could allow an attacker to execute arbitrary code with elevated privileges.
Open full assessment ↗ - CVE-2017-12729
Vulnerability Details
View details for CVE-2017-12729
A SQL Injection issue was discovered in Moxa SoftCMS Live Viewer through 1.6. An improper neutralization of special elements used in an SQL command ('SQL Injection') vulnerability has been identified. Attackers can exploit this vulnerability to access SoftCMS without knowing the user's password.
Open full assessment ↗ - CVE-2017-12728
Vulnerability Details
View details for CVE-2017-12728
An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services.
Open full assessment ↗ - CVE-2017-12726
Vulnerability Details
View details for CVE-2017-12726
A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.
Open full assessment ↗ - CVE-2017-12725
Vulnerability Details
View details for CVE-2017-12725
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.
Open full assessment ↗ - CVE-2017-12724
Vulnerability Details
View details for CVE-2017-12724
A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections.
Open full assessment ↗ - CVE-2017-12723
Vulnerability Details
View details for CVE-2017-12723
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
Open full assessment ↗ - CVE-2017-12722
Vulnerability Details
View details for CVE-2017-12722
An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.
Open full assessment ↗ - CVE-2017-12721
Vulnerability Details
View details for CVE-2017-12721
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack.
Open full assessment ↗ - CVE-2017-12720
Vulnerability Details
View details for CVE-2017-12720
An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections.
Open full assessment ↗ - CVE-2017-12719
Vulnerability Details
View details for CVE-2017-12719
An Untrusted Pointer Dereference issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A remote attacker is able to execute code to dereference a pointer within the program causing the application to become unavailable.
Open full assessment ↗ - CVE-2017-12718
Vulnerability Details
View details for CVE-2017-12718
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.
Open full assessment ↗ - CVE-2017-12717
Vulnerability Details
View details for CVE-2017-12717
An Uncontrolled Search Path Element issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A maliciously crafted dll file placed earlier in the search path may allow an attacker to execute code within the context of the application.
Open full assessment ↗ - CVE-2017-12716
Vulnerability Details
View details for CVE-2017-12716
Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information without encryption. CVSS v3 base score: 3.1, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Open full assessment ↗ - CVE-2017-12714
Vulnerability Details
View details for CVE-2017-12714
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base score: 5.3, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Open full assessment ↗ - CVE-2017-12713
Vulnerability Details
View details for CVE-2017-12713
An Incorrect Permission Assignment for Critical Resource issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Multiple files and folders with ACLs that affect other users are allowed to be modified by non-administrator accounts.
Open full assessment ↗ - CVE-2017-12712
Vulnerability Details
View details for CVE-2017-12712
The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF communications. CVSS v3 base score: 7.5, CVSS vector string: AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Abbott has developed a firmware update to help mitigate the identified vulnerabilities.
Open full assessment ↗ - CVE-2017-12711
Vulnerability Details
View details for CVE-2017-12711
An Incorrect Privilege Assignment issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. A built-in user account has been granted a sensitive privilege that may allow a user to elevate to administrative privileges.
Open full assessment ↗ - CVE-2017-12710
Vulnerability Details
View details for CVE-2017-12710
A SQL Injection issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. By submitting a specially crafted parameter, it is possible to inject arbitrary SQL statements that could allow an attacker to obtain sensitive information.
Open full assessment ↗ - CVE-2017-12709
Vulnerability Details
View details for CVE-2017-12709
A Use of Hard-Coded Credentials issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded credentials, which could allow for unauthorized local low-privileged access to the device.
Open full assessment ↗ - CVE-2017-12708
Vulnerability Details
View details for CVE-2017-12708
An Improper Restriction Of Operations Within The Bounds Of A Memory Buffer issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. Researchers have identified multiple vulnerabilities that allow invalid locations to be referenced for the memory buffer, which may allow an attacker to execute arbitrary code or cause the system to crash.
Open full assessment ↗ - CVE-2017-12707
Vulnerability Details
View details for CVE-2017-12707
A Stack-based Buffer Overflow issue was discovered in SpiderControl SCADA MicroBrowser Versions 1.6.30.144 and prior. Opening a maliciously crafted html file may cause a stack overflow.
Open full assessment ↗