- CVE-2017-9664
Vulnerability Details
View details for CVE-2017-9664
In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP request which refers to files using ../../ relative paths. Once the internal password file is retrieved, the password hash can be identified using a brute force attack. There is also an exploit allowing running of commands after authorization.
Open full assessment ↗ - CVE-2017-9663
Vulnerability Details
View details for CVE-2017-9663
An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory.
Open full assessment ↗ - CVE-2017-9662
Vulnerability Details
View details for CVE-2017-9662
An Improper Privilege Management issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. Monitouch V-SFT is installed in a directory with weak access controls by default, which could allow an authenticated attacker with local access to escalate privileges.
Open full assessment ↗ - CVE-2017-9661
Vulnerability Details
View details for CVE-2017-9661
An Uncontrolled Search Path Element issue was discovered in SIMPlight SCADA Software version 4.3.0.27 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to place a malicious DLL file within the search path resulting in execution of arbitrary code.
Open full assessment ↗ - CVE-2017-9660
Vulnerability Details
View details for CVE-2017-9660
A Heap-Based Buffer Overflow was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. A heap-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution.
Open full assessment ↗ - CVE-2017-9659
Vulnerability Details
View details for CVE-2017-9659
A Stack-Based Buffer Overflow issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. The stack-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution.
Open full assessment ↗ - CVE-2017-9658
Vulnerability Details
View details for CVE-2017-9658
Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
Open full assessment ↗ - CVE-2017-9657
Vulnerability Details
View details for CVE-2017-9657
Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the central monitor, and thus should be operating in local monitoring mode (local audio-on, screen-on), but the MX40 WLAN itself can instead still be operating in telemetry mode (local audio-off, screen-off). If a patient experiences an alarm event and clinical staff expects the MX40 to provide local alarming when it is not available from the local device, a delay of treatment can occur. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
Open full assessment ↗ - CVE-2017-9656
Vulnerability Details
View details for CVE-2017-9656
The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.
Open full assessment ↗ - CVE-2017-9655
Vulnerability Details
View details for CVE-2017-9655
A Cross-Site Scripting issue was discovered in OSIsoft PI Integrator for Business Analytics before 2016 R2, PI Integrator for Microsoft Azure before 2016 R2 SP1, and PI Integrator for SAP HANA before 2017. An attacker may be able to upload a malicious script that attempts to redirect users to a malicious web site.
Open full assessment ↗ - CVE-2017-9654
Vulnerability Details
View details for CVE-2017-9654
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.
Open full assessment ↗ - CVE-2017-9653
Vulnerability Details
View details for CVE-2017-9653
An Improper Authorization issue was discovered in OSIsoft PI Integrator for Business Analytics before 2016 R2, PI Integrator for Microsoft Azure before 2016 R2 SP1, and PI Integrator for SAP HANA before 2017. An attacker is able to gain privileged access to the system while unauthorized.
Open full assessment ↗ - CVE-2017-9650
Vulnerability Details
View details for CVE-2017-9650
An Unrestricted Upload of File with Dangerous Type issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to upload a malicious file allowing the execution of arbitrary code.
Open full assessment ↗ - CVE-2017-9649
Vulnerability Details
View details for CVE-2017-9649
A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware.
Open full assessment ↗ - CVE-2017-9648
Vulnerability Details
View details for CVE-2017-9648
An Uncontrolled Search Path Element issue was discovered in Solar Controls WATTConfig M Software Version 2.5.10.1 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file.
Open full assessment ↗ - CVE-2017-9647
Vulnerability Details
View details for CVE-2017-9647
A Stack-Based Buffer Overflow issue was discovered in the Continental AG Infineon S-Gold 2 (PMB 8876) chipset on BMW several models produced between 2009-2010, Ford a limited number of P-HEV vehicles, Infiniti 2013 JX35, Infiniti 2014-2016 QX60, Infiniti 2014-2016 QX60 Hybrid, Infiniti 2014-2015 QX50, Infiniti 2014-2015 QX50 Hybrid, Infiniti 2013 M37/M56, Infiniti 2014-2016 Q70, Infiniti 2014-2016 Q70L, Infiniti 2015-2016 Q70 Hybrid, Infiniti 2013 QX56, Infiniti 2014-2016 QX 80, and Nissan 2011-2015 Leaf. An attacker with a physical connection to the TCU may exploit a buffer overflow condition that exists in the processing of AT commands. This may allow arbitrary code execution on the baseband radio processor of the TCU.
Open full assessment ↗ - CVE-2017-9646
Vulnerability Details
View details for CVE-2017-9646
An Uncontrolled Search Path Element issue was discovered in Solar Controls Heating Control Downloader (HCDownloader) Version 1.0.1.15 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file.
Open full assessment ↗ - CVE-2017-9645
Vulnerability Details
View details for CVE-2017-9645
An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). Decryption of data is possible at the hardware level.
Open full assessment ↗ - CVE-2017-9644
Vulnerability Details
View details for CVE-2017-9644
An Unquoted Search Path or Element issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An unquoted search path vulnerability may allow a non-privileged local attacker to change files in the installation directory and execute arbitrary code with elevated privileges.
Open full assessment ↗ - CVE-2017-9641
Vulnerability Details
View details for CVE-2017-9641
PI Coresight 2016 R2 contains a cross-site request forgery vulnerability that may allow access to the PI system. OSIsoft recommends that users upgrade to PI Vision 2017 or greater to mitigate this vulnerability.
Open full assessment ↗ - CVE-2017-9640
Vulnerability Details
View details for CVE-2017-9640
A Path Traversal issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web prior to 6.5; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to overwrite files that are used to execute code. This vulnerability does not affect version 6.5 of the software.
Open full assessment ↗ - CVE-2017-9639
Vulnerability Details
View details for CVE-2017-9639
An issue was discovered in Fuji Electric V-Server Version 3.3.22.0 and prior. A memory corruption vulnerability has been identified (aka improper restriction of operations within the bounds of a memory buffer), which may allow remote code execution.
Open full assessment ↗ - CVE-2017-9638
Vulnerability Details
View details for CVE-2017-9638
Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.
Open full assessment ↗ - CVE-2017-9637
Vulnerability Details
View details for CVE-2017-9637
Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.
Open full assessment ↗