CVE 2017 Directory: Page 386
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
14,765 published records with identifiers assigned to 2017. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 386 of 616
- CVE-2017-7916
Vulnerability Details
View details for CVE-2017-7916
A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted.
Open full assessment ↗ - CVE-2017-7915
Vulnerability Details
View details for CVE-2017-7915
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. An attacker can freely use brute force to determine parameters needed to bypass authentication.
Open full assessment ↗ - CVE-2017-7914
Vulnerability Details
View details for CVE-2017-7914
A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10.20121012, 6.10-20140122, 7.00-20121012, 7.00-20130108, 7.00-20130325, 7.00-20130619, 7.00-20140128, 7.00-20140310, 7.00-20140429, 7.00-20140621, 7.00-20140729, 7.00-20141022, 8.00-20140730, and 8.00-20141023. There is no authorization check when connecting to the device, allowing an attacker remote access.
Open full assessment ↗ - CVE-2017-7913
Vulnerability Details
View details for CVE-2017-7913
A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application's configuration file contains parameters that represent passwords in plaintext.
Open full assessment ↗ - CVE-2017-7912
Vulnerability Details
View details for CVE-2017-7912
Hanwha Techwin SRN-4000, SRN-4000 firmware versions prior to SRN4000_v2.16_170401, A specially crafted http request and response could allow an attacker to gain access to the device management page with admin privileges without proper authentication.
Open full assessment ↗ - CVE-2017-7911
Vulnerability Details
View details for CVE-2017-7911
A Code Injection issue was discovered in CyberVision Kaa IoT Platform, Version 0.7.4. An insufficient-encapsulation vulnerability has been identified, which may allow remote code execution.
Open full assessment ↗ - CVE-2017-7910
Vulnerability Details
View details for CVE-2017-7910
A Stack-Based Buffer Overflow issue was discovered in Digital Canal Structural Wind Analysis versions 9.1 and prior. An attacker may be able to run arbitrary code by remotely exploiting an executable to perform a denial-of-service attack.
Open full assessment ↗ - CVE-2017-7909
Vulnerability Details
View details for CVE-2017-7909
A Use of Client-Side Authentication issue was discovered in Advantech B+B SmartWorx MESR901 firmware versions 1.5.2 and prior. The web interface uses JavaScript to check client authentication and redirect unauthorized users. Attackers may intercept requests and bypass authentication to access restricted web pages.
Open full assessment ↗ - CVE-2017-7908
Vulnerability Details
View details for CVE-2017-7908
A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls.
Open full assessment ↗ - CVE-2017-7907
Vulnerability Details
View details for CVE-2017-7907
An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network.
Open full assessment ↗ - CVE-2017-7906
Vulnerability Details
View details for CVE-2017-7906
In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user.
Open full assessment ↗ - CVE-2017-7905
Vulnerability Details
View details for CVE-2017-7905
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
Open full assessment ↗ - CVE-2017-7903
Vulnerability Details
View details for CVE-2017-7903
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2017-7902
Vulnerability Details
View details for CVE-2017-7902
A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed.
Open full assessment ↗ - CVE-2017-7901
Vulnerability Details
View details for CVE-2017-7901
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.
Open full assessment ↗ - CVE-2017-7899
Vulnerability Details
View details for CVE-2017-7899
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available for unauthorized retrieval.
Open full assessment ↗ - CVE-2017-7898
Vulnerability Details
View details for CVE-2017-7898
An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2017-7897
Vulnerability Details
View details for CVE-2017-7897
A cross-site scripting (XSS) vulnerability in the MantisBT (2.3.x before 2.3.2) Timeline include page, used in My View (my_view_page.php) and User Information (view_user_page.php) pages, allows remote attackers to inject arbitrary code (if CSP settings permit it) through crafted PATH_INFO in a URL, due to use of unsanitized $_SERVER['PHP_SELF'] to generate URLs.
Open full assessment ↗ - CVE-2017-7896
Vulnerability Details
View details for CVE-2017-7896
Trend Micro InterScan Messaging Security Virtual Appliance (IMSVA) 9.1 before CP 1644 has XSS.
Open full assessment ↗ - CVE-2017-7895
Vulnerability Details
View details for CVE-2017-7895
The NFSv2 and NFSv3 server implementations in the Linux kernel through 4.10.13 lack certain checks for the end of a buffer, which allows remote attackers to trigger pointer-arithmetic errors or possibly have unspecified other impact via crafted requests, related to fs/nfsd/nfs3xdr.c and fs/nfsd/nfsxdr.c.
Open full assessment ↗ - CVE-2017-7894
Vulnerability Details
View details for CVE-2017-7894
WinDjView 2.1 might allow user-assisted attackers to execute code via a crafted .djvu file, because of a "User Mode Write AV near NULL" in WinDjView.exe. One threat model is a victim who obtains an untrusted .djvu file from a remote location and issues several user-defined commands.
Open full assessment ↗ - CVE-2017-7893
Vulnerability Details
View details for CVE-2017-7893
In SaltStack Salt before 2016.3.6, compromised salt-minions can impersonate the salt-master.
Open full assessment ↗ - CVE-2017-7892
Vulnerability Details
View details for CVE-2017-7892
Sandstorm Cap'n Proto before 0.5.3.1 allows remote crashes related to a compiler optimization. A remote attacker can trigger a segfault in a 32-bit libcapnp application because Cap'n Proto relies on pointer arithmetic calculations that overflow. An example compiler with optimization that elides a bounds check in such calculations is Apple LLVM version 8.1.0 (clang-802.0.41). The attack vector is a crafted far pointer within a message.
Open full assessment ↗ - CVE-2017-7891
Vulnerability Details
View details for CVE-2017-7891
sourcebans-pp (SourceBans++) 1.5.4.7 has XSS in admin.comms.php via the rebanid parameter.
Open full assessment ↗