- CVE-2018-19012
Vulnerability Details
View details for CVE-2018-19012
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk mode, an attacker is able to take control of the operating system.
Open full assessment ↗ - CVE-2018-19011
Vulnerability Details
View details for CVE-2018-19011
CX-Supervisor (Versions 3.42 and prior) can execute code that has been injected into a project file. An attacker could exploit this to execute code under the privileges of the application.
Open full assessment ↗ - CVE-2018-19010
Vulnerability Details
View details for CVE-2018-19010
Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to disrupt patient monitoring by causing the monitor to repeatedly reboot until it falls back to default configuration and loses network connectivity.
Open full assessment ↗ - CVE-2018-19009
Vulnerability Details
View details for CVE-2018-19009
Pilz PNOZmulti Configurator prior to version 10.9 allows an authenticated attacker with local access to the system containing the PNOZmulti Configurator software to view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can modify data on the HMI device.
Open full assessment ↗ - CVE-2018-19008
Vulnerability Details
View details for CVE-2018-19008
The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.
Open full assessment ↗ - CVE-2018-19007
Vulnerability Details
View details for CVE-2018-19007
In Geutebrueck GmbH E2 Camera Series versions prior to 1.12.0.25 the DDNS configuration (in the Network Configuration panel) is vulnerable to an OS system command injection as root.
Open full assessment ↗ - CVE-2018-19006
Vulnerability Details
View details for CVE-2018-19006
OSIsoft PI Vision, versions PI Vision 2017, and PI Vision 2017 R2, The application contains a cross-site scripting vulnerability where displays that reference AF elements and attributes containing JavaScript are affected. This vulnerability requires the ability of authorized AF users to store JavaScript in AF elements and attributes.
Open full assessment ↗ - CVE-2018-19005
Vulnerability Details
View details for CVE-2018-19005
Cscape, Version 9.80.75.3 SP3 and prior. An improper input validation vulnerability has been identified that may be exploited by processing specially crafted POC files lacking user input validation. This may allow an attacker to read confidential information and remotely execute arbitrary code.
Open full assessment ↗ - CVE-2018-19004
Vulnerability Details
View details for CVE-2018-19004
LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration.
Open full assessment ↗ - CVE-2018-19003
Vulnerability Details
View details for CVE-2018-19003
GE Mark VIe, EX2100e, EX2100e_Reg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100e_Reg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fails to restrict the ability of an attacker to gain access to restricted information.
Open full assessment ↗ - CVE-2018-19002
Vulnerability Details
View details for CVE-2018-19002
LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.
Open full assessment ↗ - CVE-2018-19001
Vulnerability Details
View details for CVE-2018-19001
Philips HealthSuite Health Android App, all versions. The software uses simple encryption that is not strong enough for the level of protection required.
Open full assessment ↗ - CVE-2018-19000
Vulnerability Details
View details for CVE-2018-19000
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.
Open full assessment ↗ - CVE-2018-18999
Vulnerability Details
View details for CVE-2018-18999
WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack.
Open full assessment ↗ - CVE-2018-18998
Vulnerability Details
View details for CVE-2018-18998
LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.
Open full assessment ↗ - CVE-2018-18997
Vulnerability Details
View details for CVE-2018-18997
Pluto Safety PLC Gateway Ethernet devices in ABB GATE-E1 and GATE-E2 all versions allows an unauthenticated attacker using the administrative web interface to insert an HTML/Javascript payload into any of the device properties, which may allow an attacker to display/execute the payload in a visitor browser.
Open full assessment ↗ - CVE-2018-18996
Vulnerability Details
View details for CVE-2018-18996
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server.
Open full assessment ↗ - CVE-2018-18995
Vulnerability Details
View details for CVE-2018-18995
Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.
Open full assessment ↗ - CVE-2018-18994
Vulnerability Details
View details for CVE-2018-18994
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration.
Open full assessment ↗ - CVE-2018-18993
Vulnerability Details
View details for CVE-2018-18993
Two stack-based buffer overflow vulnerabilities have been discovered in CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior). When processing project files, the application allows input data to exceed the buffer. An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application.
Open full assessment ↗ - CVE-2018-18992
Vulnerability Details
View details for CVE-2018-18992
LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.
Open full assessment ↗ - CVE-2018-18991
Vulnerability Details
View details for CVE-2018-18991
Reflected cross-site scripting (non-persistent) in SCADA WebServer (Versions prior to 2.03.0001) could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser.
Open full assessment ↗ - CVE-2018-18990
Vulnerability Details
View details for CVE-2018-18990
LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.
Open full assessment ↗ - CVE-2018-18989
Vulnerability Details
View details for CVE-2018-18989
In CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior), when processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
Open full assessment ↗