CVE 2018 Directory: Page 144
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
16,188 published records with identifiers assigned to 2018. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 144 of 675
- CVE-2018-17925
Vulnerability Details
View details for CVE-2018-17925
Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted.
Open full assessment ↗ - CVE-2018-17924
Vulnerability Details
View details for CVE-2018-17924
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-17923
Vulnerability Details
View details for CVE-2018-17923
SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that an attacker with physical access to the product may able to reprogram it.
Open full assessment ↗ - CVE-2018-17922
Vulnerability Details
View details for CVE-2018-17922
Circontrol CirCarLife all versions prior to 4.3.1, the PAP credentials of the device are stored in clear text in a log file that is accessible without authentication.
Open full assessment ↗ - CVE-2018-17921
Vulnerability Details
View details for CVE-2018-17921
SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that may allow an attacker to force-pair the device without human interaction.
Open full assessment ↗ - CVE-2018-17919
Vulnerability Details
View details for CVE-2018-17919
All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use an undocumented user account "default" with its default password to login to XMeye and access/view video streams.
Open full assessment ↗ - CVE-2018-17918
Vulnerability Details
View details for CVE-2018-17918
Circontrol CirCarLife all versions prior to 4.3.1, authentication to the device can be bypassed by entering the URL of a specific page.
Open full assessment ↗ - CVE-2018-17917
Vulnerability Details
View details for CVE-2018-17917
All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use MAC addresses to enumerate potential Cloud IDs. Using this ID, the attacker can discover and connect to valid devices using one of the supported apps.
Open full assessment ↗ - CVE-2018-17916
Vulnerability Details
View details for CVE-2018-17916
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine.
Open full assessment ↗ - CVE-2018-17915
Vulnerability Details
View details for CVE-2018-17915
All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server do not encrypt all device communication. This includes the XMeye service and firmware update communication. This could allow an attacker to eavesdrop on video feeds, steal XMeye login credentials, or impersonate the update server with malicious update code.
Open full assessment ↗ - CVE-2018-17914
Vulnerability Details
View details for CVE-2018-17914
InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime.
Open full assessment ↗ - CVE-2018-17913
Vulnerability Details
View details for CVE-2018-17913
A type confusion vulnerability exists when processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, which may allow an attacker to execute code in the context of the application.
Open full assessment ↗ - CVE-2018-17912
Vulnerability Details
View details for CVE-2018-17912
An XXE vulnerability exists in CASE Suite Versions 3.10 and prior when processing parameter entities, which may allow remote file disclosure.
Open full assessment ↗ - CVE-2018-17911
Vulnerability Details
View details for CVE-2018-17911
LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution.
Open full assessment ↗ - CVE-2018-17910
Vulnerability Details
View details for CVE-2018-17910
WebAccess Versions 8.3.2 and prior. The application fails to properly validate the length of user-supplied data, causing a buffer overflow condition that allows for arbitrary remote code execution.
Open full assessment ↗ - CVE-2018-17909
Vulnerability Details
View details for CVE-2018-17909
When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior, the application fails to check if it is referencing freed memory, which may allow an attacker to execute code under the context of the application.
Open full assessment ↗ - CVE-2018-17908
Vulnerability Details
View details for CVE-2018-17908
WebAccess Versions 8.3.2 and prior. During installation, the application installer disables user access control and does not re-enable it after the installation is complete. This could allow an attacker to run elevated arbitrary code.
Open full assessment ↗ - CVE-2018-17907
Vulnerability Details
View details for CVE-2018-17907
When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with the value of an offset, an attacker can force the application to read a value outside of an array.
Open full assessment ↗ - CVE-2018-17906
Vulnerability Details
View details for CVE-2018-17906
Philips iSite and IntelliSpace PACS, iSite PACS, all versions, and IntelliSpace PACS, all versions. Default credentials and no authentication within third party software may allow an attacker to compromise a component of the system.
Open full assessment ↗ - CVE-2018-17905
Vulnerability Details
View details for CVE-2018-17905
When processing project files in Omron CX-Supervisor Versions 3.4.1.0 and prior and tampering with a specific byte, memory corruption may occur within a specific object.
Open full assessment ↗ - CVE-2018-17904
Vulnerability Details
View details for CVE-2018-17904
Reliance 4 SCADA/HMI, Version 4.7.3 Update 3 and prior. This vulnerability could allow an unauthorized attacker to inject arbitrary code.
Open full assessment ↗ - CVE-2018-17903
Vulnerability Details
View details for CVE-2018-17903
SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to a replay attack and command forgery.
Open full assessment ↗ - CVE-2018-17902
Vulnerability Details
View details for CVE-2018-17902
Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The application utilizes multiple methods of session management which could result in a denial of service to the remote management functions.
Open full assessment ↗ - CVE-2018-17901
Vulnerability Details
View details for CVE-2018-17901
LAquis SCADA Versions 4.1.0.3870 and prior, when processing project files the application fails to sanitize user input prior to performing write operations on a stack object, which may allow an attacker to execute code under the current process.