CVE 2018 Directory: Page 510
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
16,188 published records with identifiers assigned to 2018. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 510 of 675
- CVE-2018-5462
Vulnerability Details
View details for CVE-2018-5462
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an SSL incorrect hostname certificate vulnerability this could allow an attacker to gain unauthorized access to resources and information.
Open full assessment ↗ - CVE-2018-5461
Vulnerability Details
View details for CVE-2018-5461
An Inadequate Encryption Strength issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An inadequate encryption strength vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack.
Open full assessment ↗ - CVE-2018-5459
Vulnerability Details
View details for CVE-2018-5459
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455.
Open full assessment ↗ - CVE-2018-5458
Vulnerability Details
View details for CVE-2018-5458
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability using SSL legacy encryption that could allow an attacker to gain unauthorized access to resources and information.
Open full assessment ↗ - CVE-2018-5457
Vulnerability Details
View details for CVE-2018-5457
A uncontrolled search path element issue was discovered in Vyaire Medical CareFusion Upgrade Utility used with Windows XP systems, Versions 2.0.2.2 and prior versions. A successful exploit of this vulnerability requires the local user to install a crafted DLL on the target machine. The application loads the DLL and gives the attacker access at the same privilege level as the application.
Open full assessment ↗ - CVE-2018-5455
Vulnerability Details
View details for CVE-2018-5455
A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions.
Open full assessment ↗ - CVE-2018-5454
Vulnerability Details
View details for CVE-2018-5454
Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to remotely execute arbitrary code during runtime.
Open full assessment ↗ - CVE-2018-5453
Vulnerability Details
View details for CVE-2018-5453
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing the device to become unavailable.
Open full assessment ↗ - CVE-2018-5452
Vulnerability Details
View details for CVE-2018-5452
A Stack-based Buffer Overflow issue was discovered in Emerson Process Management ControlWave Micro Process Automation Controller: ControlWave Micro [ProConOS v.4.01.280] firmware: CWM v.05.78.00 and prior. A stack-based buffer overflow vulnerability caused by sending crafted packets on Port 20547 could force the PLC to change its state into halt mode.
Open full assessment ↗ - CVE-2018-5451
Vulnerability Details
View details for CVE-2018-5451
In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the claim is correct. This weakness can lead to the exposure of resources or functionality to unintended actors, possibly providing attackers with sensitive information or the ability to execute arbitrary code.
Open full assessment ↗ - CVE-2018-5449
Vulnerability Details
View details for CVE-2018-5449
A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of service attack.
Open full assessment ↗ - CVE-2018-5448
Medtronic 2090 Carelink Programmer Relative Path Traversal
View details for CVE-2018-5448
Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-5447
Vulnerability Details
View details for CVE-2018-5447
An Improper Input Validation issue was discovered in Nari PCS-9611 relay. An improper input validation vulnerability has been identified that affects a service within the software that may allow a remote attacker to arbitrarily read/access system resources and affect the availability of the system.
Open full assessment ↗ - CVE-2018-5446
Medtronic 2090 Carelink Programmer Storing Passwords in a Recoverable Format
View details for CVE-2018-5446
Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-5445
Vulnerability Details
View details for CVE-2018-5445
A Path Traversal issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. An attacker has read access to files within the directory structure of the target device.
Open full assessment ↗ - CVE-2018-5443
Vulnerability Details
View details for CVE-2018-5443
A SQL Injection issue was discovered in Advantech WebAccess/SCADA versions prior to V8.2_20170817. WebAccess/SCADA does not properly sanitize its inputs for SQL commands.
Open full assessment ↗ - CVE-2018-5442
Vulnerability Details
View details for CVE-2018-5442
A Stack-based Buffer Overflow issue was discovered in Fuji Electric V-Server VPR 4.0.1.0 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.
Open full assessment ↗ - CVE-2018-5441
Vulnerability Details
View details for CVE-2018-5441
An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages.
Open full assessment ↗ - CVE-2018-5440
Vulnerability Details
View details for CVE-2018-5440
A Stack-based Buffer Overflow issue was discovered in 3S-Smart CODESYS Web Server. Specifically: all Microsoft Windows (also WinCE) based CODESYS web servers running stand-alone Version 2.3, or as part of the CODESYS runtime system running prior to Version V1.1.9.19. A crafted request may cause a buffer overflow and could therefore execute arbitrary code on the web server or lead to a denial-of-service condition due to a crash in the web server.
Open full assessment ↗ - CVE-2018-5439
Vulnerability Details
View details for CVE-2018-5439
A Command Injection issue was discovered in Nortek Linear eMerge E3 series Versions V0.32-07e and prior. A remote attacker may be able to execute arbitrary code on a target machine with elevated privileges.
Open full assessment ↗ - CVE-2018-5438
Vulnerability Details
View details for CVE-2018-5438
Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously logged in user. This vulnerability exists when using ISCV together with an Electronic Medical Record (EMR) system, where ISCV is in KIOSK mode for multiple users and using Windows authentication. This may allow an attacker to gain unauthorized access to patient health information and potentially modify this information.
Open full assessment ↗ - CVE-2018-5437
TIBCO Spotfire Product Family Information Disclosure Vulnerability
View details for CVE-2018-5437
The TIBCO Spotfire Client and TIBCO Spotfire Web Player Client components of TIBCO Software Inc.'s TIBCO Spotfire Analyst, TIBCO Spotfire Analytics Platform for AWS Marketplace, TIBCO Spotfire Deployment Kit, TIBCO Spotfire Desktop, and TIBCO Spotfire Desktop Language Packs contain multiple vulnerabilities that may allow for unauthorized information disclosure. Affected releases are TIBCO Software Inc.'s TIBCO Spotfire Analyst: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0; 7.12.0, TIBCO Spotfire Analytics Platform for AWS Marketplace: versions up to and including 7.12.0, TIBCO Spotfire Deployment Kit: versions up to and including 7.8.0; 7.9.0;7.9.1;7.10.0;7.10.1;7.11.0; 7.12.0, TIBCO Spotfire Desktop: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0;7.12.0, TIBCO Spotfire Desktop Language Packs: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0.
Open full assessment ↗ - CVE-2018-5436
TIBCO Spotfire Server information disclosure vulnerabilities
View details for CVE-2018-5436
The Spotfire server component of TIBCO Software Inc.'s TIBCO Spotfire Analytics Platform for AWS Marketplace, and TIBCO Spotfire Server contain multiple vulnerabilities that may allow for the disclosure of information, including user and data source credentials. Affected releases are TIBCO Software Inc.'s TIBCO Spotfire Analytics Platform for AWS Marketplace: versions up to and including 7.12.0, TIBCO Spotfire Server: versions up to and including 7.8.1; 7.9.0; 7.10.0; 7.11.0; 7.12.0.
Open full assessment ↗ - CVE-2018-5435
TIBCO Spotfire Product Family Remote Code Execution Vulnerability
View details for CVE-2018-5435
The TIBCO Spotfire Client and TIBCO Spotfire Web Player Client components of TIBCO Software Inc.'s TIBCO Spotfire Analyst, TIBCO Spotfire Analytics Platform for AWS Marketplace, TIBCO Spotfire Deployment Kit, TIBCO Spotfire Desktop, and TIBCO Spotfire Desktop Language Packs contain multiple vulnerabilities that may allow for remote code execution. Affected releases are TIBCO Software Inc.'s TIBCO Spotfire Analyst: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0; 7.12.0, TIBCO Spotfire Analytics Platform for AWS Marketplace: versions up to and including 7.12.0, TIBCO Spotfire Deployment Kit: versions up to and including 7.8.0; 7.9.0;7.9.1;7.10.0;7.10.1;7.11.0; 7.12.0, TIBCO Spotfire Desktop: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0;7.12.0, TIBCO Spotfire Desktop Language Packs: versions up to and including 7.8.0; 7.9.0; 7.9.1; 7.10.0; 7.10.1; 7.11.0.
Open full assessment ↗