- CVE-2019-18249
Vulnerability Details
View details for CVE-2019-18249
Reliable Controls MACH-ProWebCom/Sys, all versions prior to 2.15 (Firmware versions prior to 8.26.4), may allow attacker to execute commands on behalf of the user when an authenticated user clicks on a malicious link.
Open full assessment ↗ - CVE-2019-18248
Vulnerability Details
View details for CVE-2019-18248
BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to the BIOTRONIK Remote Communication infrastructure.
Open full assessment ↗ - CVE-2019-18247
Vulnerability Details
View details for CVE-2019-18247
An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could cause a denial of service.
Open full assessment ↗ - CVE-2019-18246
Vulnerability Details
View details for CVE-2019-18246
BIOTRONIK CardioMessenger II, The affected products do not properly enforce mutual authentication with the BIOTRONIK Remote Communication infrastructure.
Open full assessment ↗ - CVE-2019-18245
Vulnerability Details
View details for CVE-2019-18245
Reliable Controls LicenseManager versions 3.4 and prior may allow an authenticated user to insert malicious code into the system root path, which may allow execution of code with elevated privileges of the application.
Open full assessment ↗ - CVE-2019-18244
Vulnerability Details
View details for CVE-2019-18244
In OSIsoft PI System multiple products and versions, a local attacker could view sensitive information in log files when service accounts are customized during installation or upgrade of PI Vision. The update fixes a previously reported issue.
Open full assessment ↗ - CVE-2019-18243
Vulnerability Details
View details for CVE-2019-18243
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through the registry. This may allow privilege escalation.
Open full assessment ↗ - CVE-2019-18242
Vulnerability Details
View details for CVE-2019-18242
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, frequent and multiple requests for short-term use may cause the web server to fail.
Open full assessment ↗ - CVE-2019-18241
Vulnerability Details
View details for CVE-2019-18241
In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the affected products is configured to allow weak ciphers. This could enable an unauthorized attacker with access to the network to capture and replay the session and gain unauthorized access to the EC40/80 hub.
Open full assessment ↗ - CVE-2019-18240
Vulnerability Details
View details for CVE-2019-18240
In Fuji Electric V-Server 4.0.6 and prior, several heap-based buffer overflows have been identified, which may allow an attacker to remotely execute arbitrary code.
Open full assessment ↗ - CVE-2019-18238
Vulnerability Details
View details for CVE-2019-18238
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account.
Open full assessment ↗ - CVE-2019-18236
Vulnerability Details
View details for CVE-2019-18236
Multiple buffer overflow vulnerabilities exist when the PLC Editor Version 1.3.5_20190129 processes project files. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
Open full assessment ↗ - CVE-2019-18235
Vulnerability Details
View details for CVE-2019-18235
Advantech Spectre RT ERT351 Versions 5.1.3 and prior has insufficient login authentication parameters required for the web application may allow an attacker to gain full access using a brute-force password attack.
Open full assessment ↗ - CVE-2019-18234
Vulnerability Details
View details for CVE-2019-18234
Equinox Control Expert all versions, is vulnerable to an SQL injection attack, which may allow an attacker to remotely execute arbitrary code.
Open full assessment ↗ - CVE-2019-18233
Vulnerability Details
View details for CVE-2019-18233
In Advantech Spectre RT Industrial Routers ERT351 5.1.3 and prior, the affected product does not neutralize special characters in the error response, allowing attackers to use a reflected XSS attack.
Open full assessment ↗ - CVE-2019-18232
Vulnerability Details
View details for CVE-2019-18232
SafeNet Sentinel LDK License Manager, all versions prior to 7.101(only Microsoft Windows versions are affected) is vulnerable when configured as a service. This vulnerability may allow an attacker with local access to create, write, and/or delete files in system folder using symbolic links, leading to a privilege escalation. This vulnerability could also be used by an attacker to execute a malicious DLL, which could impact the integrity and availability of the system.
Open full assessment ↗ - CVE-2019-18231
Vulnerability Details
View details for CVE-2019-18231
Advantech Spectre RT ERT351 Versions 5.1.3 and prior logins and passwords are transmitted in clear text form, which may allow an attacker to intercept the request.
Open full assessment ↗ - CVE-2019-18230
Vulnerability Details
View details for CVE-2019-18230
Honeywell equIP and Performance series IP cameras, multiple versions, A vulnerability exists where the affected product allows unauthenticated access to audio streaming over HTTP.
Open full assessment ↗ - CVE-2019-18229
Vulnerability Details
View details for CVE-2019-18229
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. Lack of sanitization of user-supplied input cause SQL injection vulnerabilities. An attacker can leverage these vulnerabilities to disclose information.
Open full assessment ↗ - CVE-2019-18228
Vulnerability Details
View details for CVE-2019-18228
Honeywell equIP series IP cameras Multiple equIP Series Cameras, A vulnerability exists in the affected products where a specially crafted HTTP packet request could result in a denial of service.
Open full assessment ↗ - CVE-2019-18227
Vulnerability Details
View details for CVE-2019-18227
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. XXE vulnerabilities exist that may allow disclosure of sensitive data.
Open full assessment ↗ - CVE-2019-18226
Vulnerability Details
View details for CVE-2019-18226
Honeywell equIP series and Performance series IP cameras and recorders, A vulnerability exists in the affected products where IP cameras and recorders have a potential replay attack vulnerability as a weak authentication method is retained for compatibility with legacy products.
Open full assessment ↗ - CVE-2019-18225
Vulnerability Details
View details for CVE-2019-18225
An issue was discovered in Citrix Application Delivery Controller (ADC) and Gateway before 10.5 build 70.8, 11.x before 11.1 build 63.9, 12.0 before build 62.10, 12.1 before build 54.16, and 13.0 before build 41.28. An attacker with management-interface access can bypass authentication to obtain appliance administrative access. These products formerly used the NetScaler brand name.
Open full assessment ↗ - CVE-2019-18224
Vulnerability Details
View details for CVE-2019-18224
idn2_to_ascii_4i in lib/lookup.c in GNU libidn2 before 2.1.1 has a heap-based buffer overflow via a long domain string.
Open full assessment ↗