CVE 2020 Directory: Page 117
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
19,402 published records with identifiers assigned to 2020. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 117 of 809
- CVE-2020-27298
Philips Interventional Workstations OS Command Injection
View details for CVE-2020-27298
Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), ViewForum (Release 6.3V1L10). The software constructs all or part of an OS command using externally influenced input from an upstream component but does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when sent to a downstream component.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-27297
Vulnerability Details
View details for CVE-2020-27297
The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code on the OPC UA Tunneller (versions prior to 6.3.0.8233).
Open full assessment ↗ - CVE-2020-27295
Vulnerability Details
View details for CVE-2020-27295
The affected product has uncontrolled resource consumption issues, which may allow an attacker to cause a denial-of-service condition on the OPC UA Tunneller (versions prior to 6.3.0.8233).
Open full assessment ↗ - CVE-2020-27293
Vulnerability Details
View details for CVE-2020-27293
Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior has a type confusion issue while processing project files, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2020-27291
Vulnerability Details
View details for CVE-2020-27291
Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior is vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2020-27290
Vulnerability Details
View details for CVE-2020-27290
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an information disclosure vulnerability in the ventilator allows attackers with physical access to the configuration interface's logs to get valid checksums for tampered configuration files.
Open full assessment ↗ - CVE-2020-27289
Vulnerability Details
View details for CVE-2020-27289
Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior has a null pointer dereference issue while processing project files, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2020-27288
Vulnerability Details
View details for CVE-2020-27288
An untrusted pointer dereference has been identified in the way TPEditor(v1.98 and prior) processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution.
Open full assessment ↗ - CVE-2020-27287
Vulnerability Details
View details for CVE-2020-27287
Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2020-27285
Vulnerability Details
View details for CVE-2020-27285
The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database without authentication.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-27284
Vulnerability Details
View details for CVE-2020-27284
TPEditor (v1.98 and prior) is vulnerable to two out-of-bounds write instances in the way it processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution.
Open full assessment ↗ - CVE-2020-27283
Vulnerability Details
View details for CVE-2020-27283
An attacker could send a specially crafted message to Crimson 3.1 (Build versions prior to 3119.001) that could leak arbitrary memory locations.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-27282
Vulnerability Details
View details for CVE-2020-27282
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the device persistently unusable by uploading specially crafted configuration files.
Open full assessment ↗ - CVE-2020-27281
Vulnerability Details
View details for CVE-2020-27281
A stack-based buffer overflow may exist in Delta Electronics CNCSoft ScreenEditor versions 1.01.26 and prior when processing specially crafted project files, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2020-27280
Vulnerability Details
View details for CVE-2020-27280
A use after free issue has been identified in the way ISPSoft(v3.12 and prior) processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution.
Open full assessment ↗ - CVE-2020-27279
Vulnerability Details
View details for CVE-2020-27279
A NULL pointer deference vulnerability has been identified in the protocol converter. An attacker could send a specially crafted packet that could reboot the device running Crimson 3.1 (Build versions prior to 3119.001).
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-27278
Vulnerability Details
View details for CVE-2020-27278
In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device’s configuration interface.
Open full assessment ↗ - CVE-2020-27277
Vulnerability Details
View details for CVE-2020-27277
Delta Electronics DOPSoft Version 4.0.8.21 and prior has a null pointer dereference issue while processing project files, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2020-27276
Vulnerability Details
View details for CVE-2020-27276
SOOIL Developments Co Ltd DiabecareRS,AnyDana-i & AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i & AnyDana-A mobile apps doesn't use adequate measures to authenticate the communicating entities before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the authentication sequence via Bluetooth Low Energy.
Open full assessment ↗ - CVE-2020-27275
Vulnerability Details
View details for CVE-2020-27275
Delta Electronics DOPSoft Version 4.0.8.21 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2020-27274
Vulnerability Details
View details for CVE-2020-27274
Some parsing functions in the affected product do not check the return value of malloc and the thread handling the message is forced to close, which may lead to a denial-of-service condition on the OPC UA Tunneller (versions prior to 6.3.0.8233).
Open full assessment ↗ - CVE-2020-27272
Vulnerability Details
View details for CVE-2020-27272
SOOIL Developments CoLtd DiabecareRS, AnyDana-i, AnyDana-A, The communication protocol of the insulin pump and AnyDana-i,AnyDana-A mobile apps doesn't use adequate measures to authenticate the pump before exchanging keys, which allows unauthenticated, physically proximate attackers to eavesdrop the keys and spoof the pump via BLE.
Open full assessment ↗ - CVE-2020-27270
Vulnerability Details
View details for CVE-2020-27270
SOOIL Developments CoLtd DiabecareRS, AnyDana-i ,AnyDana-A, communication protocol of the insulin pump & AnyDana-i,AnyDana-A mobile apps doesnt use adequate measures to protect encryption keys in transit which allows unauthenticated physically proximate attacker to sniff keys via (BLE).
Open full assessment ↗ - CVE-2020-27269
Vulnerability Details
View details for CVE-2020-27269
In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, the communication protocol of the insulin pump and its AnyDana-i and AnyDana-A mobile applications lacks replay protection measures, which allows unauthenticated, physically proximate attackers to replay communication sequences via Bluetooth Low Energy.
Open full assessment ↗