CVE 2020 Directory: Page 574
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
19,402 published records with identifiers assigned to 2020. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 574 of 809
- CVE-2020-7002
Vulnerability Details
View details for CVE-2020-7002
Delta Industrial Automation CNCSoft ScreenEditor, v1.00.96 and prior. Multiple stack-based buffer overflows can be exploited when a valid user opens a specially crafted, malicious input file.
Open full assessment ↗ - CVE-2020-7001
Vulnerability Details
View details for CVE-2020-7001
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.
Open full assessment ↗ - CVE-2020-7000
Vulnerability Details
View details for CVE-2020-7000
VISAM VBASE Editor version 11.5.0.2 and VBASE Web-Remote Module may allow an unauthenticated attacker to discover the cryptographic key from the web server and gain information about the login and the encryption/decryption mechanism, which may be exploited to bypass authentication of the HTML5 HMI web interface.
Open full assessment ↗ - CVE-2020-6999
Vulnerability Details
View details for CVE-2020-6999
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, some of the parameters in the setting pages do not ensure text is the correct size for its buffer.
Open full assessment ↗ - CVE-2020-6998
Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation
View details for CVE-2020-6998
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-6997
Vulnerability Details
View details for CVE-2020-6997
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext.
Open full assessment ↗ - CVE-2020-6996
Vulnerability Details
View details for CVE-2020-6996
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
Open full assessment ↗ - CVE-2020-6995
Vulnerability Details
View details for CVE-2020-6995
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the application utilizes weak password requirements, which may allow an attacker to gain unauthorized access.
Open full assessment ↗ - CVE-2020-6994
Vulnerability Details
View details for CVE-2020-6994
A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30.
Open full assessment ↗ - CVE-2020-6993
Vulnerability Details
View details for CVE-2020-6993
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, an attacker can gain access to sensitive information from the web service without authorization.
Open full assessment ↗ - CVE-2020-6992
Vulnerability Details
View details for CVE-2020-6992
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.
Open full assessment ↗ - CVE-2020-6991
Vulnerability Details
View details for CVE-2020-6991
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, weak password requirements may allow an attacker to gain access using brute force.
Open full assessment ↗ - CVE-2020-6990
Vulnerability Details
View details for CVE-2020-6990
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-6989
Vulnerability Details
View details for CVE-2020-6989
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code.
Open full assessment ↗ - CVE-2020-6988
Vulnerability Details
View details for CVE-2020-6988
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the victim’s MicroLogix controller. The controller will then respond to the client with used password values to authenticate the user on the client-side. This method of authentication may allow an attacker to bypass authentication altogether, disclose sensitive information, or leak credentials.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-6987
Vulnerability Details
View details for CVE-2020-6987
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.
Open full assessment ↗ - CVE-2020-6986
Vulnerability Details
View details for CVE-2020-6986
In all versions of Omron PLC CJ Series, an attacker can send a series of specific data packets within a short period, causing a service error on the PLC Ethernet module, which in turn causes a PLC service denied result.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-6985
Vulnerability Details
View details for CVE-2020-6985
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.
Open full assessment ↗ - CVE-2020-6984
Vulnerability Details
View details for CVE-2020-6984
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-6983
Vulnerability Details
View details for CVE-2020-6983
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered.
Open full assessment ↗ - CVE-2020-6982
Vulnerability Details
View details for CVE-2020-6982
In Honeywell WIN-PAK 4.7.2, Web and prior versions, the header injection vulnerability has been identified, which may allow remote code execution.
Open full assessment ↗ - CVE-2020-6981
Vulnerability Details
View details for CVE-2020-6981
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
Open full assessment ↗ - CVE-2020-6980
Vulnerability Details
View details for CVE-2020-6980
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext.
Open full assessment ↗ - CVE-2020-6979
Vulnerability Details
View details for CVE-2020-6979
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered.
Open full assessment ↗