CVE 2021 Directory: Page 216
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
22,608 published records with identifiers assigned to 2021. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 216 of 942
- CVE-2021-40381
Vulnerability Details
View details for CVE-2021-40381
An issue was discovered on Compro IP70 2.08_7130218, IP570 2.08_7130520, IP60, and TN540 devices. index_MJpeg.cgi allows video access.
Open full assessment ↗ - CVE-2021-40380
Vulnerability Details
View details for CVE-2021-40380
An issue was discovered on Compro IP70 2.08_7130218, IP570 2.08_7130520, IP60, and TN540 devices. cameralist.cgi and setcamera.cgi disclose credentials.
Open full assessment ↗ - CVE-2021-40379
Vulnerability Details
View details for CVE-2021-40379
An issue was discovered on Compro IP70 2.08_7130218, IP570 2.08_7130520, IP60, and TN540 devices. rstp://.../medias2 does not require authorization.
Open full assessment ↗ - CVE-2021-40378
Vulnerability Details
View details for CVE-2021-40378
An issue was discovered on Compro IP70 2.08_7130218, IP570 2.08_7130520, IP60, and TN540 devices. /cgi-bin/support/killps.cgi deletes all data from the device.
Open full assessment ↗ - CVE-2021-40377
Vulnerability Details
View details for CVE-2021-40377
SmarterTools SmarterMail 16.x before build 7866 has stored XSS. The application fails to sanitize email content, thus allowing one to inject HTML and/or JavaScript into a page that will then be processed and stored by the application.
Open full assessment ↗ - CVE-2021-40376
Vulnerability Details
View details for CVE-2021-40376
otris Update Manager 1.2.1.0 allows local users to achieve SYSTEM access via unauthenticated calls to exposed interfaces over a .NET named pipe. A remote attack may be possible as well, by leveraging WsHTTPBinding for HTTP traffic on TCP port 9000.
Open full assessment ↗ - CVE-2021-40375
Vulnerability Details
View details for CVE-2021-40375
Apperta Foundation OpenEyes 3.5.1 allows remote attackers to view the sensitive information of patients without having the intended level of privilege. Despite OpenEyes returning a Forbidden error message, the contents of a patient's profile are still returned in the server response. This response can be read in an intercepting proxy or by viewing the page source. Sensitive information returned in responses includes patient PII and medication records or history.
Open full assessment ↗ - CVE-2021-40374
Vulnerability Details
View details for CVE-2021-40374
A stored cross-site scripting (XSS) vulnerability was identified in Apperta Foundation OpenEyes 3.5.1. Updating a patient's details allows remote attackers to inject arbitrary web script or HTML via the Address1 parameter. This JavaScript then executes when the patient profile is loaded, which could be used in a XSS attack.
Open full assessment ↗ - CVE-2021-40373
Vulnerability Details
View details for CVE-2021-40373
playSMS before 1.4.5 allows Arbitrary Code Execution by entering PHP code at the #tabs-information-page of core_main_config, and then executing that code via the index.php?app=main&inc=core_welcome URI.
Open full assessment ↗ - CVE-2021-40371
Vulnerability Details
View details for CVE-2021-40371
Gridpro Request Management for Windows Azure Pack before 2.0.7912 allows Directory Traversal for remote code execution, as demonstrated by ..\\ in a scriptName JSON value to ServiceManagerTenant/GetVisibilityMap.
Open full assessment ↗ - CVE-2021-40369
XSS vulnerability on Denounce plugin
View details for CVE-2021-40369
A carefully crafted plugin link invocation could trigger an XSS vulnerability on Apache JSPWiki, related to the Denounce plugin, which could allow the attacker to execute javascript in the victim's browser and get some sensitive information about the victim. Apache JSPWiki users should upgrade to 2.11.0 or later.
Open full assessment ↗ - CVE-2021-40368
Vulnerability Details
View details for CVE-2021-40368
A vulnerability has been identified in SIMATIC S7-400 CPU 412-1 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 DP V7 (All versions), SIMATIC S7-400 CPU 412-2 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414-2 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 DP V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-2 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-2 DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 417-4 DP V7 (All versions), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.10), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants) (All versions < V10.1), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions < V8.2.3), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 V7 (All versions), SIPLUS S7-400 CPU 417-4 V7 (All versions). Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a Denial-of-Service condition. A restart is needed to restore normal operations.
siemens · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-40367
Vulnerability Details
View details for CVE-2021-40367
A vulnerability has been identified in syngo fastView (All versions). The affected application lacks proper validation of user-supplied data when parsing DICOM files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15097)
siemens · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-40366
Vulnerability Details
View details for CVE-2021-40366
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.
Open full assessment ↗ - CVE-2021-40365
Vulnerability Details
View details for CVE-2021-40365
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
siemens · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-40364
Vulnerability Details
View details for CVE-2021-40364
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
siemens · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-40363
Vulnerability Details
View details for CVE-2021-40363
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.
Open full assessment ↗ - CVE-2021-40360
Vulnerability Details
View details for CVE-2021-40360
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
Open full assessment ↗ - CVE-2021-40359
Vulnerability Details
View details for CVE-2021-40359
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.
siemens · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-40358
Vulnerability Details
View details for CVE-2021-40358
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
siemens · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-40357
Vulnerability Details
View details for CVE-2021-40357
A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.10), Teamcenter Active Workspace V5.0 (All versions < V5.0.8), Teamcenter Active Workspace V5.1 (All versions < V5.1.5), Teamcenter Active Workspace V5.2 (All versions < V5.2.1). A path traversal vulnerability in the application could allow an attacker to bypass certain restrictions such as direct access to other services within the host.
Open full assessment ↗ - CVE-2021-40356
Vulnerability Details
View details for CVE-2021-40356
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.
Open full assessment ↗ - CVE-2021-40355
Vulnerability Details
View details for CVE-2021-40355
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The affected application contains Insecure Direct Object Reference (IDOR) vulnerability that allows an attacker to use user-supplied input to access objects directly.
Open full assessment ↗ - CVE-2021-40354
Vulnerability Details
View details for CVE-2021-40354
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The "surrogate" functionality on the user profile of the application does not perform sufficient access control that could lead to an account takeover. Any profile on the application can perform this attack and access any other user assigned tasks via the "inbox/surrogate tasks".
Open full assessment ↗