CVE 2021 Directory: Page 417
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
22,608 published records with identifiers assigned to 2021. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 417 of 942
- CVE-2021-33017
Philips IntelliBridge EC 40 and EC 80 Hub Authentication Bypass Using an Alternate Path or Channel
View details for CVE-2021-33017
The standard access path of the IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) requires authentication, but the product has an alternate path or channel that does not require authentication.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33016
KUKA KR C4 - Use of Hard-Coded Credentials
View details for CVE-2021-33016
An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33015
Vulnerability Details
View details for CVE-2021-33015
Cscape (All Versions prior to 9.90 SP5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds write via an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process.
Open full assessment ↗ - CVE-2021-33014
KUKA KR C4 - Use of Hard-Coded Credentials
View details for CVE-2021-33014
An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33013
mySCADA myPRO Improper Access Control
View details for CVE-2021-33013
mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33012
Vulnerability Details
View details for CVE-2021-33012
Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault whenever the controller is switched to RUN mode.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33011
Vulnerability Details
View details for CVE-2021-33011
All versions of the afffected TOYOPUC-PC10 Series,TOYOPUC-Plus Series,TOYOPUC-PC3J/PC2J Series, TOYOPUC-Nano Series products may not be able to properly process an ICMP flood, which may allow an attacker to deny Ethernet communications between affected devices.
Open full assessment ↗ - CVE-2021-33010
AVEVA System Platform Uncaught Exception
View details for CVE-2021-33010
An exception is thrown from a function in AVEVA System Platform versions 2017 through 2020 R2 P01, but it is not caught, which may cause a denial-of-service condition.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33009
mySCADA myPRO Unrestricted Upload of File with Dangerous Type
View details for CVE-2021-33009
mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to the file system.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33008
AVEVA System Platform Missing Authentication for Critical Function
View details for CVE-2021-33008
AVEVA System Platform versions 2017 through 2020 R2 P01 does not perform any authentication for functionality that requires a provable user identity.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33007
Vulnerability Details
View details for CVE-2021-33007
A heap-based buffer overflow in Delta Electronics TPEditor: v1.98.06 and prior may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2021-33005
mySCADA myPRO Path Traversal
View details for CVE-2021-33005
mySCADA myPRO versions prior to 8.20.0 allows an unauthenticated remote attacker to upload arbitrary files to arbitrary directories.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33004
Vulnerability Details
View details for CVE-2021-33004
The affected product is vulnerable to memory corruption condition due to lack of proper validation of user supplied files, which may allow an attacker to execute arbitrary code. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
Open full assessment ↗ - CVE-2021-33003
Vulnerability Details
View details for CVE-2021-33003
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to retrieve passwords in cleartext due to a weak hashing algorithm.
Open full assessment ↗ - CVE-2021-33002
Vulnerability Details
View details for CVE-2021-33002
Opening a maliciously crafted project file may cause an out-of-bounds write, which may allow an attacker to execute arbitrary code. User interaction is require on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
Open full assessment ↗ - CVE-2021-33001
xArrow SCADA Cross-site Scripting
View details for CVE-2021-33001
xArrow SCADA versions 7.2 and prior is vulnerable to cross-site scripting due to parameter ‘bdate’ of the resource xhisvalue.htm, which may allow an unauthorized attacker to execute arbitrary code.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-33000
Vulnerability Details
View details for CVE-2021-33000
Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior).
Open full assessment ↗ - CVE-2021-32999
AVEVA SuiteLink Server Improper Handling of Exceptional Conditions
View details for CVE-2021-32999
Improper handling of exceptional conditions in SuiteLink server while processing command 0x01
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-32998
Vulnerability Details
View details for CVE-2021-32998
The FANUC R-30iA and R-30iB series controllers are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code. INIT START/restore from backup required.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-32997
Baker Hughes Bently Nevada 3500 - Use of Password Hash with Insufficient Computational Effort
View details for CVE-2021-32997
The affected Baker Hughes Bentley Nevada products (3500 System 1 6.x, Part No. 3060/00 versions 6.98 and prior, 3500 System 1, Part No. 3071/xx & 3072/xx versions 21.1 HF1 and prior, 3500 Rack Configuration, Part No. 129133-01 versions 6.4 and prior, and 3500/22M Firmware, Part No. 288055-01 versions 5.05 and prior) utilize a weak encryption algorithm for storage and transmission of sensitive data, which may allow an attacker to more easily obtain credentials used for access.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-32996
Vulnerability Details
View details for CVE-2021-32996
The FANUC R-30iA and R-30iB series controllers are vulnerable to integer coercion errors, which cause the device to crash. A restart is required.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-32995
Vulnerability Details
View details for CVE-2021-32995
Cscape (All Versions prior to 9.90 SP5) lacks proper validation of user-supplied data when parsing project files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to execute code in the context of the current process.
Open full assessment ↗ - CVE-2021-32994
Softing OPC-UA C++ SDK Improper Restriction of Operations within the Bounds of a Memory Buffer
View details for CVE-2021-32994
Softing OPC UA C++ SDK (Software Development Kit) versions from 5.59 to 5.64 exported library functions don't properly validate received extension objects, which may allow an attacker to crash the software by sending a variety of specially crafted packets to access several unexpected memory locations.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-32993
Philips IntelliBridge EC 40 and EC 80 Hub Use of Hard-coded Credentials
View details for CVE-2021-32993
IntelliBridge EC 40 and 60 Hub (C.00.04 and prior) contains hard-coded credentials, such as a password or a cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
icscert · Calculated from the published vector.
Open full assessment ↗