CVE 2021 Directory: Page 447
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
22,608 published records with identifiers assigned to 2021. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 447 of 942
- CVE-2021-31916
Vulnerability Details
View details for CVE-2021-31916
An out-of-bounds (OOB) memory write flaw was found in list_devices in drivers/md/dm-ioctl.c in the Multi-device driver module in the Linux kernel before 5.12. A bound check failure allows an attacker with special user (CAP_SYS_ADMIN) privilege to gain access to out-of-bounds memory leading to a system crash or a leak of internal kernel information. The highest threat from this vulnerability is to system availability.
Open full assessment ↗ - CVE-2021-31915
Vulnerability Details
View details for CVE-2021-31915
In JetBrains TeamCity before 2020.2.4, OS command injection leading to remote code execution was possible.
Open full assessment ↗ - CVE-2021-31914
Vulnerability Details
View details for CVE-2021-31914
In JetBrains TeamCity before 2020.2.4 on Windows, arbitrary code execution on TeamCity Server was possible.
Open full assessment ↗ - CVE-2021-31913
Vulnerability Details
View details for CVE-2021-31913
In JetBrains TeamCity before 2020.2.3, insufficient checks of the redirect_uri were made during GitHub SSO token exchange.
Open full assessment ↗ - CVE-2021-31912
Vulnerability Details
View details for CVE-2021-31912
In JetBrains TeamCity before 2020.2.3, account takeover was potentially possible during a password reset.
Open full assessment ↗ - CVE-2021-31911
Vulnerability Details
View details for CVE-2021-31911
In JetBrains TeamCity before 2020.2.3, reflected XSS was possible on several pages.
Open full assessment ↗ - CVE-2021-31910
Vulnerability Details
View details for CVE-2021-31910
In JetBrains TeamCity before 2020.2.3, information disclosure via SSRF was possible.
Open full assessment ↗ - CVE-2021-31909
Vulnerability Details
View details for CVE-2021-31909
In JetBrains TeamCity before 2020.2.3, argument injection leading to remote code execution was possible.
Open full assessment ↗ - CVE-2021-31908
Vulnerability Details
View details for CVE-2021-31908
In JetBrains TeamCity before 2020.2.3, stored XSS was possible on several pages.
Open full assessment ↗ - CVE-2021-31907
Vulnerability Details
View details for CVE-2021-31907
In JetBrains TeamCity before 2020.2.2, permission checks for changing TeamCity plugins were implemented improperly.
Open full assessment ↗ - CVE-2021-31906
Vulnerability Details
View details for CVE-2021-31906
In JetBrains TeamCity before 2020.2.2, audit logs were not sufficient when an administrator uploaded a file.
Open full assessment ↗ - CVE-2021-31905
Vulnerability Details
View details for CVE-2021-31905
In JetBrains YouTrack before 2020.6.8801, information disclosure in an issue preview was possible.
Open full assessment ↗ - CVE-2021-31904
Vulnerability Details
View details for CVE-2021-31904
In JetBrains TeamCity before 2020.2.2, XSS was potentially possible on the test history page.
Open full assessment ↗ - CVE-2021-31903
Vulnerability Details
View details for CVE-2021-31903
In JetBrains YouTrack before 2021.1.9819, a pull request's title was sanitized insufficiently, leading to XSS.
Open full assessment ↗ - CVE-2021-31902
Vulnerability Details
View details for CVE-2021-31902
In JetBrains YouTrack before 2020.6.6600, access control during the exporting of issues was implemented improperly.
Open full assessment ↗ - CVE-2021-31901
Vulnerability Details
View details for CVE-2021-31901
In JetBrains Hub before 2021.1.13079, two-factor authentication wasn't enabled properly for the All Users group.
Open full assessment ↗ - CVE-2021-31900
Vulnerability Details
View details for CVE-2021-31900
In JetBrains Code With Me bundled to the compatible IDE versions before 2021.1, a client could open a browser on a host.
Open full assessment ↗ - CVE-2021-31899
Vulnerability Details
View details for CVE-2021-31899
In JetBrains Code With Me bundled to the compatible IDEs before version 2021.1, the client could execute code in read-only mode.
Open full assessment ↗ - CVE-2021-31898
Vulnerability Details
View details for CVE-2021-31898
In JetBrains WebStorm before 2021.1, HTTP requests were used instead of HTTPS.
Open full assessment ↗ - CVE-2021-31897
Vulnerability Details
View details for CVE-2021-31897
In JetBrains WebStorm before 2021.1, code execution without user confirmation was possible for untrusted projects.
Open full assessment ↗ - CVE-2021-31895
Vulnerability Details
View details for CVE-2021-31895
A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.7), RUGGEDCOM i801 (All versions < V4.3.7), RUGGEDCOM i802 (All versions < V4.3.7), RUGGEDCOM i803 (All versions < V4.3.7), RUGGEDCOM M2100 (All versions < V4.3.7), RUGGEDCOM M2200 (All versions < V4.3.7), RUGGEDCOM M969 (All versions < V4.3.7), RUGGEDCOM RMC30 (All versions < V4.3.7), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.7), RUGGEDCOM RMC8388 V5.X (All versions < V5.5.4), RUGGEDCOM RP110 (All versions < V4.3.7), RUGGEDCOM RS1600 (All versions < V4.3.7), RUGGEDCOM RS1600F (All versions < V4.3.7), RUGGEDCOM RS1600T (All versions < V4.3.7), RUGGEDCOM RS400 (All versions < V4.3.7), RUGGEDCOM RS401 (All versions < V4.3.7), RUGGEDCOM RS416 (All versions < V4.3.7), RUGGEDCOM RS416P (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.5.4), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.7), RUGGEDCOM RS416v2 V5.X (All versions < 5.5.4), RUGGEDCOM RS8000 (All versions < V4.3.7), RUGGEDCOM RS8000A (All versions < V4.3.7), RUGGEDCOM RS8000H (All versions < V4.3.7), RUGGEDCOM RS8000T (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900G (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RS900GP (All versions < V4.3.7), RUGGEDCOM RS900L (All versions < V4.3.7), RUGGEDCOM RS900W (All versions < V4.3.7), RUGGEDCOM RS910 (All versions < V4.3.7), RUGGEDCOM RS910L (All versions < V4.3.7), RUGGEDCOM RS910W (All versions < V4.3.7), RUGGEDCOM RS920L (All versions < V4.3.7), RUGGEDCOM RS920W (All versions < V4.3.7), RUGGEDCOM RS930L (All versions < V4.3.7), RUGGEDCOM RS930W (All versions < V4.3.7), RUGGEDCOM RS940G (All versions < V4.3.7), RUGGEDCOM RS969 (All versions < V4.3.7), RUGGEDCOM RSG2100 (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2100P (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V4.X (All versions < V4.3.7), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.5.4), RUGGEDCOM RSG2200 (All versions < V4.3.7), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2288 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300 V5.X (All versions < V5.5.4), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.7), RUGGEDCOM RSG2300P V5.X (All versions < V5.5.4), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.7), RUGGEDCOM RSG2488 V5.X (All versions < V5.5.4), RUGGEDCOM RSG907R (All versions < V5.5.4), RUGGEDCOM RSG908C (All versions < V5.5.4), RUGGEDCOM RSG909R (All versions < V5.5.4), RUGGEDCOM RSG910C (All versions < V5.5.4), RUGGEDCOM RSG920P V4.X (All versions < V4.3.7), RUGGEDCOM RSG920P V5.X (All versions < V5.5.4), RUGGEDCOM RSL910 (All versions < V5.5.4), RUGGEDCOM RST2228 (All versions < V5.5.4), RUGGEDCOM RST2228P (All versions < V5.5.4), RUGGEDCOM RST916C (All versions < V5.5.4), RUGGEDCOM RST916P (All versions < V5.5.4). The DHCP client in affected devices fails to properly sanitize incoming DHCP packets. This could allow an unauthenticated remote attacker to cause memory to be overwritten, potentially allowing remote code execution.
siemens · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-31894
Vulnerability Details
View details for CVE-2021-31894
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
Open full assessment ↗ - CVE-2021-31893
Vulnerability Details
View details for CVE-2021-31893
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). The affected software contains a buffer overflow vulnerability while handling certain files that could allow a local attacker to trigger a denial-of-service condition or potentially lead to remote code execution.
Open full assessment ↗ - CVE-2021-31892
Vulnerability Details
View details for CVE-2021-31892
A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.
Open full assessment ↗