CVE 2021 Directory: Page 572
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
22,608 published records with identifiers assigned to 2021. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 572 of 942
- CVE-2021-27413
Vulnerability Details
View details for CVE-2021-27413
Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2021-27412
Vulnerability Details
View details for CVE-2021-27412
Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2021-27411
Micrium OS Integer Overflow or Wraparound
View details for CVE-2021-27411
Micrium OS Versions 5.10.1 and prior are vulnerable to integer wrap-around in functions Mem_DynPoolCreate, Mem_DynPoolCreateHW and Mem_PoolCreate. This unverified memory assignment can lead to arbitrary memory allocation, resulting in unexpected behavior such as very small blocks of memory being allocated instead of very large ones.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-27410
Vulnerability Details
View details for CVE-2021-27410
The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Open full assessment ↗ - CVE-2021-27408
Vulnerability Details
View details for CVE-2021-27408
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Open full assessment ↗ - CVE-2021-27406
PerFact OpenVPN-Client
View details for CVE-2021-27406
An attacker can take leverage on PerFact OpenVPN-Client versions 1.4.1.0 and prior to send the config command from any application running on the local host machine to force the back-end server into initializing a new open-VPN instance with arbitrary open-VPN configuration. This could result in the attacker achieving execution with privileges of a SYSTEM user.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-27405
Vulnerability Details
View details for CVE-2021-27405
A ReDoS (regular expression denial of service) flaw was found in the @progfay/scrapbox-parser package before 6.0.3 for Node.js.
Open full assessment ↗ - CVE-2021-27404
Vulnerability Details
View details for CVE-2021-27404
Askey RTF8115VW BR_SV_g11.11_RTF_TEF001_V6.54_V014 devices allow injection of a Host HTTP header.
Open full assessment ↗ - CVE-2021-27403
Vulnerability Details
View details for CVE-2021-27403
Askey RTF8115VW BR_SV_g11.11_RTF_TEF001_V6.54_V014 devices allow cgi-bin/te_acceso_router.cgi curWebPage XSS.
Open full assessment ↗ - CVE-2021-27402
Vulnerability Details
View details for CVE-2021-27402
The SAS Admin portal of Mitel MiCollab before 9.2 FP2 could allow an unauthenticated attacker to access (view and modify) user data by injecting arbitrary directory paths due to improper URL validation, aka Directory Traversal.
Open full assessment ↗ - CVE-2021-27401
Vulnerability Details
View details for CVE-2021-27401
The Join Meeting page of Mitel MiCollab Web Client before 9.2 FP2 could allow an attacker to access (view and modify) user data by executing arbitrary code due to insufficient input validation, aka Cross-Site Scripting (XSS).
Open full assessment ↗ - CVE-2021-27400
Vulnerability Details
View details for CVE-2021-27400
HashiCorp Vault and Vault Enterprise Cassandra integrations (storage backend and database secrets engine plugin) did not validate TLS certificates when connecting to Cassandra clusters. Fixed in 1.6.4 and 1.7.1
Open full assessment ↗ - CVE-2021-27399
Vulnerability Details
View details for CVE-2021-27399
A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820)
Open full assessment ↗ - CVE-2021-27398
Vulnerability Details
View details for CVE-2021-27398
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290)
Open full assessment ↗ - CVE-2021-27397
Vulnerability Details
View details for CVE-2021-27397
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287)
Open full assessment ↗ - CVE-2021-27396
Vulnerability Details
View details for CVE-2021-27396
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279)
Open full assessment ↗ - CVE-2021-27395
Vulnerability Details
View details for CVE-2021-27395
A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data.
Open full assessment ↗ - CVE-2021-27394
Vulnerability Details
View details for CVE-2021-27394
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.19), Mendix Applications using Mendix 8 (All versions < V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions < V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions < V8.6.9), Mendix Applications using Mendix 9 (All versions < V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges.
Open full assessment ↗ - CVE-2021-27393
Vulnerability Details
View details for CVE-2021-27393
A vulnerability has been identified in Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2013.08), Nucleus Source Code (Versions including affected DNS modules). The DNS client does not properly randomize UDP port numbers of DNS requests. That could allow an attacker to poison the DNS cache or spoof DNS resolving.
Open full assessment ↗ - CVE-2021-27392
Vulnerability Details
View details for CVE-2021-27392
A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server.
Open full assessment ↗ - CVE-2021-27391
Vulnerability Details
View details for CVE-2021-27391
A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2021-27390
Vulnerability Details
View details for CVE-2021-27390
A vulnerability has been identified in JT2Go (All versions < V13.1.0.3), Teamcenter Visualization (All versions < V13.1.0.3). The TIFF_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13131)
Open full assessment ↗ - CVE-2021-27389
Vulnerability Details
View details for CVE-2021-27389
A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection.
Open full assessment ↗ - CVE-2021-27388
Vulnerability Details
View details for CVE-2021-27388
SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).