CVE 2022 Directory: Page 580
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
26,449 published records with identifiers assigned to 2022. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 580 of 1103
- CVE-2022-30318
Vulnerability Details
View details for CVE-2022-30318
Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded credentials issue. The affected components are characterized as: SSH. The potential impact is: Remote code execution, manipulate configuration, denial of service. The Honeywell ControlEdge PLC and RTU product line exposes an SSH service on port 22/TCP. Login as root to this service is permitted and credentials for the root user are hardcoded without automatically changing them upon first commissioning. The credentials for the SSH service are hardcoded in the firmware. The credentials grant an attacker access to a root shell on the PLC/RTU, allowing for remote code execution, configuration manipulation and denial of service.
Open full assessment ↗ - CVE-2022-30317
Vulnerability Details
View details for CVE-2022-30317
Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols' functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service.
Open full assessment ↗ - CVE-2022-30316
Vulnerability Details
View details for CVE-2022-30316
Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability.
Open full assessment ↗ - CVE-2022-30315
Vulnerability Details
View details for CVE-2022-30315
Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
Open full assessment ↗ - CVE-2022-30314
Vulnerability Details
View details for CVE-2022-30314
Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. According to FSCT-2022-0052, there is a Honeywell Experion PKS Safety Manager hardcoded credentials issue. The affected components are characterized as: POLO bootloader. The potential impact is: Manipulate firmware. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 serial interface for firmware management purposes. When booting, the Safety Manager exposes the Enea POLO bootloader via this interface. Access to the boot configuration is controlled by means of credentials hardcoded in the Safety Manager firmware. The credentials for the bootloader are hardcoded in the firmware. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize these credentials to control the boot process and manipulate the unauthenticated firmware image (see FSCT-2022-0054).
Open full assessment ↗ - CVE-2022-30313
Vulnerability Details
View details for CVE-2022-30313
Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, there is a Honeywell Experion PKS Safety Manager multiple proprietary protocols with unauthenticated functionality issue. The affected components are characterized as: Honeywell Experion TCP (51000/TCP), Safety Builder (51010/TCP). The potential impact is: Manipulate controller state, Manipulate controller configuration, Manipulate controller logic, Manipulate controller files, Manipulate IO. The Honeywell Experion PKS Distributed Control System (DCS) Safety Manager utilizes several proprietary protocols for a wide variety of functionality, including process data acquisition, controller steering and configuration management. These protocols include: Experion TCP (51000/TCP) and Safety Builder (51010/TCP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocols in question. An attacker capable of invoking the protocols' functionalities could achieve a wide range of adverse impacts, including (but not limited to), the following: for Experion TCP (51000/TCP): Issue IO manipulation commands, Issue file read/write commands; and for Safety Builder (51010/TCP): Issue controller start/stop commands, Issue logic download/upload commands, Issue file read commands, Issue system time change commands. A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
Open full assessment ↗ - CVE-2022-30312
Vulnerability Details
View details for CVE-2022-30312
The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, there is a Trend Controls Inter-Controller (IC) protocol cleartext transmission of credentials issue. The affected components are characterized as: Inter-Controller (IC) protocol (57612/UDP). The potential impact is: Compromise of credentials. Several Trend Controls building automation controllers utilize the Inter-Controller (IC) protocol in for information exchange and automation purposes. This protocol offers authentication in the form of a 4-digit PIN in order to protect access to sensitive operations like strategy uploads and downloads as well as optional 0-30 character username and password protection for web page access protection. Both the PIN and usernames and passwords are transmitted in cleartext, allowing an attacker with passive interception capabilities to obtain these credentials. Credentials are transmitted in cleartext. An attacker who obtains Trend IC credentials can carry out sensitive engineering actions such as manipulating controller strategy or configuration settings. If the credentials in question are (re)used for other applications, their compromise could potentially facilitate lateral movement.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30311
FESTO: CECC-X-M1 and Servo Press Kit YJKP OS Command Injection vulnerability
View details for CVE-2022-30311
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CERTVDE · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30310
FESTO: CECC-X-M1 and Servo Press Kit YJKP OS Command Injection vulnerability
View details for CVE-2022-30310
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CERTVDE · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30309
FESTO: CECC-X-M1 and Servo Press Kit YJKP OS Command Injection vulnerability
View details for CVE-2022-30309
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CERTVDE · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30308
FESTO: CECC-X-M1 and Servo Press Kit YJKP OS Command Injection vulnerability
View details for CVE-2022-30308
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-on" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
CERTVDE · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30307
Vulnerability Details
View details for CVE-2022-30307
A key management error vulnerability [CWE-320] affecting the RSA SSH host key in FortiOS 7.2.0 and below, 7.0.6 and below, 6.4.9 and below may allow an unauthenticated attacker to perform a man in the middle attack.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30306
Vulnerability Details
View details for CVE-2022-30306
A stack-based buffer overflow vulnerability [CWE-121] in the CA sign functionality of FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 and below may allow an authenticated attacker to achieve arbitrary code execution via specifically crafted password.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30305
Vulnerability Details
View details for CVE-2022-30305
An insufficient logging [CWE-778] vulnerability in FortiSandbox versions 4.0.0 to 4.0.2, 3.2.0 to 3.2.3 and 3.1.0 to 3.1.5 and FortiDeceptor versions 4.2.0, 4.1.0 through 4.1.1, 4.0.0 through 4.0.2, 3.3.0 through 3.3.3, 3.2.0 through 3.2.2,3.1.0 through 3.1.1 and 3.0.0 through 3.0.2 may allow a remote attacker to repeatedly enter incorrect credentials without causing a log entry, and with no limit on the number of failed authentication attempts.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30304
Vulnerability Details
View details for CVE-2022-30304
An improper neutralization of input during web page generation vulnerability [CWE-79] in FortiAnalyzer versions prior to 7.2.1, 7.0.4 and 6.4.8 may allow a remote unauthenticated attacker to perform a stored cross site scripting (XSS) attack via the URL parameter observed in the FortiWeb attack event logview in FortiAnalyzer.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30303
Vulnerability Details
View details for CVE-2022-30303
An improper neutralization of special elements used in an os command ('OS Command Injection') [CWE-78] in FortiWeb 7.0.0 through 7.0.1, 6.3.0 through 6.3.19, 6.4 all versions may allow an authenticated attacker to execute arbitrary shell code as `root` user via crafted HTTP requests.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30302
Vulnerability Details
View details for CVE-2022-30302
Multiple relative path traversal vulnerabilities [CWE-23] in FortiDeceptor management interface 1.0.0 through 3.2.x, 3.3.0 through 3.3.2, 4.0.0 through 4.0.1 may allow a remote and authenticated attacker to retrieve and delete arbitrary files from the underlying filesystem via specially crafted web requests.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30301
Vulnerability Details
View details for CVE-2022-30301
A path traversal vulnerability [CWE-22] in FortiAP-U CLI 6.2.0 through 6.2.3, 6.0.0 through 6.0.4, 5.4.0 through 5.4.6 may allow an admin user to delete and access unauthorized files and data via specifically crafted CLI commands.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30300
Vulnerability Details
View details for CVE-2022-30300
A relative path traversal vulnerability [CWE-23] in FortiWeb 7.0.0 through 7.0.1, 6.3.6 through 6.3.18, 6.4 all versions may allow an authenticated attacker to obtain unauthorized access to files and data via specifically crafted HTTP GET requests.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30299
Vulnerability Details
View details for CVE-2022-30299
A path traversal vulnerability [CWE-23] in the API of FortiWeb 7.0.0 through 7.0.1, 6.3.0 through 6.3.19, 6.4 all versions, 6.2 all versions, 6.1 all versions, 6.0 all versions may allow an authenticated attacker to retrieve specific parts of files from the underlying file system via specially crafted web requests.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30298
Vulnerability Details
View details for CVE-2022-30298
An improper privilege management vulnerability [CWE-269] in Fortinet FortiSOAR before 7.2.1 allows a GUI user who has already found a way to modify system files (via another, unrelated and hypothetical exploit) to execute arbitrary Python commands as root.
fortinet · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30297
Vulnerability Details
View details for CVE-2022-30297
Cross-site scripting in the Intel(R) EMA software before version 1.8.0 may allow a privileged user to potentially enable escalation of privilege via local access.
intel · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30296
Vulnerability Details
View details for CVE-2022-30296
Insufficiently protected credentials in the Intel(R) Datacenter Group Event iOS application, all versions, may allow an unauthenticated user to potentially enable information disclosure via network access.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2022-30295
Vulnerability Details
View details for CVE-2022-30295
uClibc-ng through 1.0.40 and uClibc through 0.9.33.2 use predictable DNS transaction IDs that may lead to DNS cache poisoning. This is related to a reset of a value to 0x2.
Open full assessment ↗