SEVERITY AND EXPLOITATION CONTEXT

CVE-2017-2681: Vulnerability Details

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

Vulnerability Details

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.

Published CVE snapshot: 2026-10-22. Record last updated: 2024-09-10T09:33:20.658Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

siemens · CVSS 3.1: 6.5 Medium

Calculated from the published vector. Base score: 6.5. Provider-reported Base score: 6.5.

Vector and metric explanationsCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
MetricValueMeaning
Attack vector (AV)AThe attacker must share a restricted network context, such as a local segment or an adjacent protocol network.
Attack complexity (AC)LExploitation does not depend on special conditions beyond the attacker’s control.
Privileges required (PR)NThe attacker needs no privileges before exploiting the vulnerability.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Scope (S)UConsequences stay within resources managed by the same security authority.
Confidentiality (C)NNo confidentiality impact is demonstrated.
Integrity (I)NNo integrity impact is demonstrated.
Availability (A)HAvailability is completely lost, or the disruption has a direct, serious consequence.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

siemens · CVSS 4.0: 7.1 High

Calculated from the published vector. Base score: 7.1. Provider-reported Base score: 7.1.

Vector and metric explanationsCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
MetricValueMeaning
Attack vector (AV)AThe attacker must share a restricted network context, such as a local segment or an adjacent protocol network.
Attack complexity (AC)LThere is no specific security-enhancing condition that the attacker must overcome.
Attack requirements (AT)NNo particular deployment or execution prerequisite is needed.
Privileges required (PR)NThe attacker needs no privileges before exploiting the vulnerability.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Confidentiality (VC)NNo confidentiality impact is demonstrated.
Integrity (VI)NNo integrity impact is demonstrated.
Availability (VA)HAvailability is completely lost, or the disruption has a direct, serious consequence.
Confidentiality (SC)NNo impact to this property is established in a subsequent system.
Integrity (SI)NNo impact to this property is established in a subsequent system.
Availability (SA)NNo impact to this property is established in a subsequent system.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

Affected products reported by the provider

  • Siemens · Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller
  • Siemens · Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200
  • Siemens · Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
  • Siemens · IE/AS-i Link PN IO
  • Siemens · IE/PB-Link (incl. SIPLUS NET variants)
  • Siemens · SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)
  • Siemens · SCALANCE W-700 IEEE 802.11n family
  • Siemens · SCALANCE X-200 family (incl. SIPLUS NET variants)
  • Siemens · SCALANCE X-200IRT family (incl. SIPLUS NET variants)
  • Siemens · SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)
  • Siemens · SCALANCE X408 family
  • Siemens · SCALANCE X414
  • Siemens · SCALANCE XM-400 family
  • Siemens · SCALANCE XR-500 family
  • Siemens · SIMATIC CM 1542-1
  • Siemens · SIMATIC CM 1542SP-1
  • Siemens · SIMATIC CP 1243-1 (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 1243-8 IRC
  • Siemens · SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 1543-1 (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 1543SP-1 (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 1604
  • Siemens · SIMATIC CP 1616
  • Siemens · SIMATIC CP 343-1 (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 343-1 Lean (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 443-1 (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 443-1 OPC UA
  • Siemens · SIMATIC DK-16xx PN IO
  • Siemens · SIMATIC ET 200AL IM 157-1 PN
  • Siemens · SIMATIC ET 200M (incl. SIPLUS variants)
  • Siemens · SIMATIC ET 200MP IM 155-5 PN BA
  • Siemens · SIMATIC ET 200MP IM 155-5 PN HF
  • Siemens · SIMATIC ET 200MP IM 155-5 PN ST
  • Siemens · SIMATIC ET 200pro IM 154-3 PN HF
  • Siemens · SIMATIC ET 200pro IM 154-4 PN HF
  • Siemens · SIMATIC ET 200SP IM 155-6 PN BA
  • Siemens · SIMATIC ET 200SP IM 155-6 PN HF
  • Siemens · SIMATIC ET 200SP IM 155-6 PN HS
  • Siemens · SIMATIC ET 200SP IM 155-6 PN ST
  • Siemens · SIMATIC ET 200SP IM 155-6 PN ST BA
  • Siemens · SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12
  • Siemens · SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12
  • Siemens · SIMATIC ET200ecoPN, 4AO U/I 4xM12
  • Siemens · SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12
  • Siemens · SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12
  • Siemens · SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12
  • Siemens · SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12
  • Siemens · SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12
  • Siemens · SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12
  • Siemens · SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12
  • Siemens · SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12
  • Siemens · SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12
  • Siemens · SIMATIC ET200ecoPN: IO-Link Master
  • Siemens · SIMATIC ET200S (incl. SIPLUS variants)
  • Siemens · SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)
  • Siemens · SIMATIC MV420 SR-B
  • Siemens · SIMATIC MV420 SR-B Body
  • Siemens · SIMATIC MV420 SR-P
  • Siemens · SIMATIC MV420 SR-P Body
  • Siemens · SIMATIC MV440 HR
  • Siemens · SIMATIC MV440 SR
  • Siemens · SIMATIC MV440 UR
  • Siemens · SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)
  • Siemens · SIMATIC RF650R
  • Siemens · SIMATIC RF680R
  • Siemens · SIMATIC RF685R
  • Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
  • Siemens · SIMATIC S7-1500 Software Controller
  • Siemens · SIMATIC S7-200 SMART
  • Siemens · SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)
  • Siemens · SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-410 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC TDC CP51M1
  • Siemens · SIMATIC TDC CPU555
  • Siemens · SIMATIC Teleservice Adapter IE Advanced
  • Siemens · SIMATIC Teleservice Adapter IE Basic
  • Siemens · SIMATIC Teleservice Adapter IE Standard
  • Siemens · SIMATIC WinAC RTX 2010
  • Siemens · SIMATIC WinAC RTX F 2010
  • Siemens · SIMOCODE pro V PROFINET (incl. SIPLUS variants)
  • Siemens · SIMOTION
  • Siemens · SINAMICS DCM w. PN
  • Siemens · SINAMICS DCP w. PN
  • Siemens · SINAMICS G110M w. PN
  • Siemens · SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)
  • Siemens · SINAMICS G130 V4.7 w. PN
  • Siemens · SINAMICS G130 V4.8 w. PN
  • Siemens · SINAMICS G150 V4.7 w. PN
  • Siemens · SINAMICS G150 V4.8 w. PN
  • Siemens · SINAMICS S110 w. PN
  • Siemens · SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)
  • Siemens · SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)
  • Siemens · SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)
  • Siemens · SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)
  • Siemens · SINAMICS S150 V4.7 w. PN
  • Siemens · SINAMICS S150 V4.8 w. PN
  • Siemens · SINAMICS V90 w. PN
  • Siemens · SINUMERIK 828D V4.5 and prior
  • Siemens · SINUMERIK 828D V4.7
  • Siemens · SINUMERIK 840D sl V4.5 and prior
  • Siemens · SINUMERIK 840D sl V4.7
  • Siemens · SIPLUS ET 200MP IM 155-5 PN HF
  • Siemens · SIPLUS ET 200MP IM 155-5 PN HF
  • Siemens · SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL
  • Siemens · SIPLUS ET 200MP IM 155-5 PN ST
  • Siemens · SIPLUS ET 200MP IM 155-5 PN ST TX RAIL
  • Siemens · SIPLUS ET 200SP IM 155-6 PN HF
  • Siemens · SIPLUS ET 200SP IM 155-6 PN HF
  • Siemens · SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL
  • Siemens · SIPLUS ET 200SP IM 155-6 PN ST
  • Siemens · SIPLUS ET 200SP IM 155-6 PN ST BA
  • Siemens · SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL
  • Siemens · SIPLUS ET 200SP IM 155-6 PN ST TX RAIL
  • Siemens · SIRIUS ACT 3SU1 interface module PROFINET
  • Siemens · SIRIUS Motor Starter M200D PROFINET
  • Siemens · SIRIUS Soft Starter 3RW44 PN
  • Siemens · SITOP PSU8600 PROFINET
  • Siemens · SITOP UPS1600 PROFINET (incl. SIPLUS variants)
  • Siemens · Softnet PROFINET IO for PC-based Windows systems

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (5)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2017 · All published CVEs · Calculation methodology