SEVERITY AND EXPLOITATION CONTEXT

CVE-2018-4843: Vulnerability Details

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

Vulnerability Details

A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V1.7.0), SIMATIC S7-1500 Software Controller (All versions < V1.7.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.7), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.1), SIMATIC WinAC RTX 2010 (All versions < V2010 SP3), SIMATIC WinAC RTX F 2010 (All versions < V2010 SP3), SINUMERIK 828D (All versions < V4.7 SP6 HF1), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), Softnet PROFINET IO for PC-based Windows systems (All versions). Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system. The security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to recover the system.

Published CVE snapshot: 2026-10-22. Record last updated: 2024-08-05T05:18:26.626Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

siemens · CVSS 3.1: 5.9 Medium

Calculated from the published vector. Base score: 6.5. Provider-reported Base score: 6.5.

Vector and metric explanationsCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
MetricValueMeaning
Attack vector (AV)AThe attacker must share a restricted network context, such as a local segment or an adjacent protocol network.
Attack complexity (AC)LExploitation does not depend on special conditions beyond the attacker’s control.
Privileges required (PR)NThe attacker needs no privileges before exploiting the vulnerability.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Scope (S)UConsequences stay within resources managed by the same security authority.
Confidentiality (C)NNo confidentiality impact is demonstrated.
Integrity (I)NNo integrity impact is demonstrated.
Availability (A)HAvailability is completely lost, or the disruption has a direct, serious consequence.
Exploit code maturity (E)PA proof of concept is available, but substantial modification or expertise is needed for practical use.
Remediation level (RL)OAn official complete fix is available.
Report confidence (RC)CDetailed evidence or authoritative confirmation establishes the vulnerability.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

Affected products reported by the provider

  • Siemens · SIMATIC S7-400 CPU 414-3 PN/DP V7
  • Siemens · SIMATIC S7-400 CPU 414F-3 PN/DP V7
  • Siemens · SIMATIC S7-400 CPU 416-3 PN/DP V7
  • Siemens · SIMATIC S7-400 CPU 416F-3 PN/DP V7
  • Siemens · SIMATIC CP 343-1 (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)
  • Siemens · SIMATIC CP 443-1
  • Siemens · SIMATIC CP 443-1
  • Siemens · SIMATIC CP 443-1 Advanced
  • Siemens · SIMATIC ET 200pro IM154-8 PN/DP CPU
  • Siemens · SIMATIC ET 200pro IM154-8F PN/DP CPU
  • Siemens · SIMATIC ET 200pro IM154-8FX PN/DP CPU
  • Siemens · SIMATIC ET 200S IM151-8 PN/DP CPU
  • Siemens · SIMATIC ET 200S IM151-8F PN/DP CPU
  • Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
  • Siemens · SIMATIC S7-1500 Software Controller
  • Siemens · SIMATIC S7-300 CPU 314C-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315F-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315T-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317F-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317T-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317TF-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 319-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 319F-3 PN/DP
  • Siemens · SIMATIC S7-400 CPU 412-2 PN V7
  • Siemens · SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-410 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC WinAC RTX 2010
  • Siemens · SIMATIC WinAC RTX F 2010
  • Siemens · SINUMERIK 828D
  • Siemens · SIPLUS ET 200S IM151-8 PN/DP CPU
  • Siemens · SIPLUS ET 200S IM151-8F PN/DP CPU
  • Siemens · SIPLUS NET CP 443-1
  • Siemens · SIPLUS NET CP 443-1 Advanced
  • Siemens · SIPLUS S7-300 CPU 314C-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 315-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 315F-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 317-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 317F-2 PN/DP
  • Siemens · SIPLUS S7-400 CPU 414-3 PN/DP V7
  • Siemens · SIPLUS S7-400 CPU 416-3 PN/DP V7
  • Siemens · Softnet PROFINET IO for PC-based Windows systems

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (1)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2018 · All published CVEs · Calculation methodology