SEVERITY AND EXPLOITATION CONTEXT

CVE-2019-10929: Vulnerability Details

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

Vulnerability Details

A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.

Published CVE snapshot: 2026-10-22. Record last updated: 2024-08-04T22:40:15.230Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

CVSS scoring availability

No valid CVSS 4.0 or 3.1 vector is available in this snapshot. An older version may appear in the source record. No score has been inferred.

Affected products reported by the provider

  • Siemens · SIMATIC CP 1626
  • Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
  • Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
  • Siemens · SIMATIC HMI Panel (incl. SIPLUS variants)
  • Siemens · SIMATIC NET PC Software V14
  • Siemens · SIMATIC NET PC Software V15
  • Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
  • Siemens · SIMATIC S7-1500 Software Controller
  • Siemens · SIMATIC S7-PLCSIM Advanced
  • Siemens · SIMATIC STEP 7 (TIA Portal)
  • Siemens · SIMATIC WinCC (TIA Portal)
  • Siemens · SIMATIC WinCC OA
  • Siemens · SIMATIC WinCC Runtime Advanced
  • Siemens · SIMATIC WinCC Runtime Professional
  • Siemens · TIM 1531 IRC (incl. SIPLUS NET variants)

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (3)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2019 · All published CVEs · Calculation methodology