SEVERITY AND EXPLOITATION CONTEXT

CVE-2019-10943: Vulnerability Details

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

Vulnerability Details

A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.

Published CVE snapshot: 2026-10-22. Record last updated: 2024-08-04T22:40:15.602Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

CVSS scoring availability

No valid CVSS 4.0 or 3.1 vector is available in this snapshot. An older version may appear in the source record. No score has been inferred.

Affected products reported by the provider

  • Siemens · SIMATIC Drive Controller family
  • Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
  • Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
  • Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
  • Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
  • Siemens · SIMATIC S7-1500 Software Controller
  • Siemens · SIMATIC S7-1500 Software Controller
  • Siemens · SIMATIC S7-PLCSIM Advanced
  • Siemens · SIMATIC S7-PLCSIM Advanced

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (1)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2019 · All published CVEs · Calculation methodology