A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.1), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX 2010 (All versions), SIMATIC WinAC RTX F 2010 (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17). Affected devices contain a vulnerability that could cause a denial of service condition of the web server by sending specially crafted HTTP requests to ports 80/tcp and 443/tcp. Beyond the web service, no other functions or interfaces are affected by the denial of service condition.

Published CVE snapshot: 2026-10-22. Record last updated: 2024-08-05T00:05:44.018Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

siemens · CVSS 3.1: 4.8 Medium

Calculated from the published vector. Base score: 5.3. Provider-reported Base score: 5.3.

Vector and metric explanationsCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C
MetricValueMeaning
Attack vector (AV)NReachable across a network boundary, including internet or routed network paths.
Attack complexity (AC)LExploitation does not depend on special conditions beyond the attacker’s control.
Privileges required (PR)NThe attacker needs no privileges before exploiting the vulnerability.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Scope (S)UConsequences stay within resources managed by the same security authority.
Confidentiality (C)NNo confidentiality impact is demonstrated.
Integrity (I)NNo integrity impact is demonstrated.
Availability (A)LAvailability is degraded or interrupted to a limited degree.
Exploit code maturity (E)PA proof of concept is available, but substantial modification or expertise is needed for practical use.
Remediation level (RL)OAn official complete fix is available.
Report confidence (RC)CDetailed evidence or authoritative confirmation establishes the vulnerability.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

Affected products reported by the provider

  • Siemens · SIMATIC ET 200pro IM154-8 PN/DP CPU
  • Siemens · SIMATIC ET 200pro IM154-8F PN/DP CPU
  • Siemens · SIMATIC ET 200pro IM154-8FX PN/DP CPU
  • Siemens · SIMATIC ET 200S IM151-8 PN/DP CPU
  • Siemens · SIMATIC ET 200S IM151-8F PN/DP CPU
  • Siemens · SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-300 CPU 314C-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315F-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315T-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317F-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317T-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317TF-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 319-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 319F-3 PN/DP
  • Siemens · SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC WinAC RTX 2010
  • Siemens · SIMATIC WinAC RTX F 2010
  • Siemens · SIPLUS ET 200S IM151-8 PN/DP CPU
  • Siemens · SIPLUS ET 200S IM151-8F PN/DP CPU
  • Siemens · SIPLUS S7-300 CPU 314C-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 315-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 315F-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 317-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 317F-2 PN/DP

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (1)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2019 · All published CVEs · Calculation methodology