SEVERITY AND EXPLOITATION CONTEXT

CVE-2019-6568: Vulnerability Details

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

Vulnerability Details

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.

Published CVE snapshot: 2026-10-22. Record last updated: 2026-06-03T13:29:34.953Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

siemens · CVSS 3.1: 6.7 Medium

Calculated from the published vector. Base score: 7.5. Provider-reported Base score: 7.5.

Vector and metric explanationsCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
MetricValueMeaning
Attack vector (AV)NReachable across a network boundary, including internet or routed network paths.
Attack complexity (AC)LExploitation does not depend on special conditions beyond the attacker’s control.
Privileges required (PR)NThe attacker needs no privileges before exploiting the vulnerability.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Scope (S)UConsequences stay within resources managed by the same security authority.
Confidentiality (C)NNo confidentiality impact is demonstrated.
Integrity (I)NNo integrity impact is demonstrated.
Availability (A)HAvailability is completely lost, or the disruption has a direct, serious consequence.
Exploit code maturity (E)PA proof of concept is available, but substantial modification or expertise is needed for practical use.
Remediation level (RL)OAn official complete fix is available.
Report confidence (RC)CDetailed evidence or authoritative confirmation establishes the vulnerability.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

Affected products reported by the provider

  • Siemens · SIMATIC CP 1604
  • Siemens · SIMATIC CP 1616
  • Siemens · SIMATIC CP 343-1 Advanced
  • Siemens · SIMATIC CP 443-1
  • Siemens · SIMATIC CP 443-1
  • Siemens · SIMATIC CP 443-1 Advanced
  • Siemens · SIMATIC CP 443-1 OPC UA
  • Siemens · SIMATIC ET 200pro IM154-8 PN/DP CPU
  • Siemens · SIMATIC ET 200pro IM154-8F PN/DP CPU
  • Siemens · SIMATIC ET 200pro IM154-8FX PN/DP CPU
  • Siemens · SIMATIC ET 200S IM151-8 PN/DP CPU
  • Siemens · SIMATIC ET 200S IM151-8F PN/DP CPU
  • Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)
  • Siemens · SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)
  • Siemens · SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)
  • Siemens · SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)
  • Siemens · SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F
  • Siemens · SIMATIC IPC DiagMonitor
  • Siemens · SIMATIC RF182C
  • Siemens · SIMATIC RF185C
  • Siemens · SIMATIC RF186C
  • Siemens · SIMATIC RF188C
  • Siemens · SIMATIC RF600R family
  • Siemens · SIMATIC RFID 181EIP
  • Siemens · SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)
  • Siemens · SIMATIC S7-1500 Software Controller
  • Siemens · SIMATIC S7-300 CPU 314C-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315F-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 315T-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317F-2 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317T-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 317TF-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 319-3 PN/DP
  • Siemens · SIMATIC S7-300 CPU 319F-3 PN/DP
  • Siemens · SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)
  • Siemens · SIMATIC S7-PLCSIM Advanced
  • Siemens · SIMATIC Teleservice Adapter IE Advanced
  • Siemens · SIMATIC Teleservice Adapter IE Basic
  • Siemens · SIMATIC Teleservice Adapter IE Standard
  • Siemens · SIMATIC WinAC RTX 2010
  • Siemens · SIMATIC WinAC RTX F 2010
  • Siemens · SIMATIC WinCC Runtime Advanced
  • Siemens · SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)
  • Siemens · SIMOCODE pro V PROFINET (incl. SIPLUS variants)
  • Siemens · SINAMICS G130 V4.6 Control Unit
  • Siemens · SINAMICS G130 V4.7 Control Unit
  • Siemens · SINAMICS G130 V4.7 SP1 Control Unit
  • Siemens · SINAMICS G130 V4.8 Control Unit
  • Siemens · SINAMICS G130 V5.1 Control Unit
  • Siemens · SINAMICS G130 V5.1 SP1 Control Unit
  • Siemens · SINAMICS G150 V4.6 Control Unit
  • Siemens · SINAMICS G150 V4.7 Control Unit
  • Siemens · SINAMICS G150 V4.7 SP1 Control Unit
  • Siemens · SINAMICS G150 V4.8 Control Unit
  • Siemens · SINAMICS G150 V5.1 Control Unit
  • Siemens · SINAMICS G150 V5.1 SP1 Control Unit
  • Siemens · SINAMICS GH150 V4.7 (Control Unit)
  • Siemens · SINAMICS GH150 V4.8 (Control Unit)
  • Siemens · SINAMICS GL150 V4.7 (Control Unit)
  • Siemens · SINAMICS GL150 V4.8 (Control Unit)
  • Siemens · SINAMICS GM150 V4.7 (Control Unit)
  • Siemens · SINAMICS GM150 V4.8 (Control Unit)
  • Siemens · SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)
  • Siemens · SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)
  • Siemens · SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)
  • Siemens · SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)
  • Siemens · SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)
  • Siemens · SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)
  • Siemens · SINAMICS S150 V4.6 Control Unit
  • Siemens · SINAMICS S150 V4.7 Control Unit
  • Siemens · SINAMICS S150 V4.7 SP1 Control Unit
  • Siemens · SINAMICS S150 V4.8 Control Unit
  • Siemens · SINAMICS S150 V5.1 Control Unit
  • Siemens · SINAMICS S150 V5.1 SP1 Control Unit
  • Siemens · SINAMICS S210
  • Siemens · SINAMICS SL150 V4.7 (Control Unit)
  • Siemens · SINAMICS SL150 V4.8 (Control Unit)
  • Siemens · SINAMICS SM120 V4.7 (Control Unit)
  • Siemens · SINAMICS SM120 V4.8 (Control Unit)
  • Siemens · SINAMICS SM150 V4.8 (Control Unit)
  • Siemens · SIPLUS ET 200S IM151-8 PN/DP CPU
  • Siemens · SIPLUS ET 200S IM151-8F PN/DP CPU
  • Siemens · SIPLUS NET CP 343-1 Advanced
  • Siemens · SIPLUS NET CP 443-1
  • Siemens · SIPLUS NET CP 443-1 Advanced
  • Siemens · SIPLUS S7-300 CPU 314C-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 315-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 315F-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 317-2 PN/DP
  • Siemens · SIPLUS S7-300 CPU 317F-2 PN/DP
  • Siemens · SITOP Manager
  • Siemens · SITOP PSU8600
  • Siemens · SITOP UPS1600 (incl. SIPLUS variants)
  • Siemens · TIM 1531 IRC (incl. SIPLUS NET variants)

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (2)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2019 · All published CVEs · Calculation methodology