SEVERITY AND EXPLOITATION CONTEXT

CVE-2020-8478: ABB System 800xA Inter process communication vulnerability

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

ABB System 800xA Inter process communication vulnerability

Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.

Published CVE snapshot: 2026-10-22. Record last updated: 2024-08-04T10:03:44.802Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

ABB · CVSS 3.1: 5.3 Medium

Calculated from the published vector. Base score: 5.3. Provider-reported Base score: 5.3.

Vector and metric explanationsCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
MetricValueMeaning
Attack vector (AV)LRequires local access, a local execution path, or a user opening an attacker-supplied file.
Attack complexity (AC)LExploitation does not depend on special conditions beyond the attacker’s control.
Privileges required (PR)LThe attacker needs basic user capabilities before exploitation.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Scope (S)UConsequences stay within resources managed by the same security authority.
Confidentiality (C)LSome information is disclosed, with limited scope or seriousness of the direct consequence.
Integrity (I)LSome modification is possible, with limited scope or consequence.
Availability (A)LAvailability is degraded or interrupted to a limited degree.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

Affected products reported by the provider

  • ABB · OPC Server for AC 800M
  • ABB · MMS Server for AC 800M
  • ABB · Base Software for SoftControl

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (1)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2020 · All published CVEs · Calculation methodology