SEVERITY AND EXPLOITATION CONTEXT

CVE-2021-43550: Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

Philips Patient Information Center iX (PIC iX) and Efficia CM Series Use of a Broken or Risky Cryptographic Algorithm

The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versions C.02 and C.03 and Efficia CM Series Revisions A.01 to C.0x and 4.0.

Published CVE snapshot: 2026-10-22. Record last updated: 2024-09-16T19:00:27.450Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

icscert · CVSS 3.1: 5.9 Medium

Calculated from the published vector. Base score: 5.9. Provider-reported Base score: 5.9.

Vector and metric explanationsCVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N
MetricValueMeaning
Attack vector (AV)AThe attacker must share a restricted network context, such as a local segment or an adjacent protocol network.
Attack complexity (AC)HSuccessful exploitation depends on conditions beyond the attacker’s control, requiring additional preparation or execution effort.
Privileges required (PR)NThe attacker needs no privileges before exploiting the vulnerability.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Scope (S)UConsequences stay within resources managed by the same security authority.
Confidentiality (C)HAll information is disclosed, or a limited disclosure has a direct, serious confidentiality consequence.
Integrity (I)LSome modification is possible, with limited scope or consequence.
Availability (A)NNo availability impact is demonstrated.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

Affected products reported by the provider

  • Philips · Efficia CM Series
  • Philips · Patient Information Center iX (PIC iX)

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (1)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2021 · All published CVEs · Calculation methodology