SEVERITY AND EXPLOITATION CONTEXT

CVE-2022-31074: KubeEdge Cloud AdmissionController component DoS

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

KubeEdge Cloud AdmissionController component DoS

KubeEdge is an open source system for extending native containerized application orchestration capabilities to hosts at Edge. Prior to versions 1.11.1, 1.10.2, and 1.9.4, several endpoints in the Cloud AdmissionController may be susceptible to a DoS attack if an HTTP request containing a very large Body is sent to it. The consequence of the exhaustion is that the Cloud AdmissionController will be in denial of service. This bug has been fixed in Kubeedge 1.11.1, 1.10.2, and 1.9.4. There is currently no known workaround.

Published CVE snapshot: 2026-10-22. Record last updated: 2025-04-23T18:03:46.086Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

GitHub_M · CVSS 3.1: 4.5 Medium

Calculated from the published vector. Base score: 4.5. Provider-reported Base score: 4.5.

Vector and metric explanationsCVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
MetricValueMeaning
Attack vector (AV)AThe attacker must share a restricted network context, such as a local segment or an adjacent protocol network.
Attack complexity (AC)LExploitation does not depend on special conditions beyond the attacker’s control.
Privileges required (PR)HThe attacker needs substantial control, typically administrative capabilities, before exploitation.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Scope (S)UConsequences stay within resources managed by the same security authority.
Confidentiality (C)NNo confidentiality impact is demonstrated.
Integrity (I)NNo integrity impact is demonstrated.
Availability (A)HAvailability is completely lost, or the disruption has a direct, serious consequence.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

Affected products reported by the provider

  • kubeedge · kubeedge

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (1)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2022 · All published CVEs · Calculation methodology