SEVERITY AND EXPLOITATION CONTEXT

CVE-2022-50977: Multiple Innomic VibroLine VLX and avibia AVLX allow unauthenticated configuration preset change via HTTP

Review published vectors, EPSS probability and CISA KEV status independently.

Lookup reads saved CVE and CISA snapshots from this site and requests EPSS from FIRST. The CVE source is contacted when a saved record is unavailable or you request a refresh. External providers receive your IP address. Finding notes and saved assessments are not sent by this feature.

Multiple Innomic VibroLine VLX and avibia AVLX allow unauthenticated configuration preset change via HTTP

An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via HTTP.

Published CVE snapshot: 2026-10-22. Record last updated: 2026-02-02T17:25:19.355Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.

View the CVE Program source record

CERTVDE · CVSS 3.1: 7.5 High

Calculated from the published vector. Base score: 7.5. Provider-reported Base score: 7.5.

Vector and metric explanationsCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
MetricValueMeaning
Attack vector (AV)NReachable across a network boundary, including internet or routed network paths.
Attack complexity (AC)LExploitation does not depend on special conditions beyond the attacker’s control.
Privileges required (PR)NThe attacker needs no privileges before exploiting the vulnerability.
User interaction (UI)NNo other user must participate for exploitation to succeed.
Scope (S)UConsequences stay within resources managed by the same security authority.
Confidentiality (C)NNo confidentiality impact is demonstrated.
Integrity (I)NNo integrity impact is demonstrated.
Availability (A)HAvailability is completely lost, or the disruption has a direct, serious consequence.

These definitions explain provider selections; they do not independently verify exploitation.

Review vector in calculator

Affected products reported by the provider

  • Innomic · VibroLine VLX1 HD 5.0
  • Innomic · VibroLine VLX2 HD 5.0
  • Innomic · VibroLine VLX4 HD 5.0
  • Innomic · VibroLine VLX6 HD 5.0
  • Innomic · VibroLine VLX8 HD 5.0
  • avibia · AvibiaLine AVLX1 HD 5.0
  • avibia · AvibiaLine AVLX2 HD 5.0
  • avibia · AvibiaLine AVLX4 HD 5.0
  • avibia · AvibiaLine AVLX6 HD 5.0
  • avibia · AvibiaLine AVLX8 HD 5.0
  • Innomic · VibroLine VLE1 HD 5.0
  • Innomic · VibroLine VLE2 HD 5.0
  • Innomic · VibroLine VLE4 HD 5.0
  • Innomic · VibroLine VLE6 HD 5.0
  • Innomic · VibroLine VLE8 HD 5.0
  • avibia · AvibiaLine AVLE1 HD 5.0
  • avibia · AvibiaLine AVLE2 HD 5.0
  • avibia · AvibiaLine AVLE4 HD 5.0
  • avibia · AvibiaLine AVLE6 HD 5.0
  • avibia · AvibiaLine AVLE8 HD 5.0
  • Innomic · VibroLine VLE1 HD 5.0
  • Innomic · VibroLine VLE2 HD 5.0
  • Innomic · VibroLine VLE4 HD 5.0
  • Innomic · VibroLine VLE6 HD 5.0
  • Innomic · VibroLine VLE8 HD 5.0
  • Innomic · VibroLine VLE1 HD 4.0
  • Innomic · VibroLine VLE2 HD 4.0
  • Innomic · VibroLine VLE4 HD 4.0
  • Innomic · VibroLine VLE6 HD 4.0
  • Innomic · VibroLine VLE8 HD 4.0
  • Innomic · VibroLine VLX1 HD 4.0
  • Innomic · VibroLine VLX2 HD 4.0
  • Innomic · VibroLine VLX4 HD 4.0
  • Innomic · VibroLine VLX6 HD 4.0
  • Innomic · VibroLine VLX8 HD 4.0

Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.

Source references (2)

Interpret severity and exploitation separately

CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.

Browse CVEs from 2022 · All published CVEs · Calculation methodology