SEVERITY AND EXPLOITATION CONTEXT
CVE-2024-53648: Vulnerability Details
Review published vectors, EPSS probability and CISA KEV status independently.
Browse all 394,234 published CVEs
Published CVE assessments
Explore dated records with provider-attributed vectors and metric explanations. Open a record to refresh its CVSS, EPSS and KEV context.
- CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints
- CVE-2023-34362: MOVEit Transfer SQL Injection
- CVE-2024-3094: Xz: malicious code in distributed source
- CVE-2023-4966: Unauthenticated sensitive information disclosure
- CVE-2024-3400: PAN-OS: Arbitrary File Creation Leads to OS Command Injection Vulnerability in GlobalProtect
- CVE-2022-22965: Spring Framework Remote Code Execution (Spring4Shell)
- CVE-2025-5095: Burk Technology ARC Solo Missing Authentication for Critical Function
- CVE-2025-14945: Events Manager - Calendar, Bookings, Tickets, and more! <= 7.3.3 - Unauthenticated Stored Cross-Site Scripting via Event Attributes
Three signals, different questions
CVSS describes technical severity under the assumptions in a vector. EPSS estimates the probability of exploitation of a published CVE in the next 30 days. CISA KEV records vulnerabilities known to have been exploited. These signals are displayed separately; this tool does not combine them into an invented risk score.
Review the source and date
Published vectors may come from the CNA or additional record providers. Review their assumptions before using them in an assessment. Missing EPSS data is not zero probability. Absence from a retrieved KEV catalog does not prove that exploitation has never occurred. A failed source request is shown as unavailable, not as a negative result.
Sources: CVE Program, FIRST EPSS and CISA KEV mirror. Check vendor advisories for affected versions and remediation guidance.
Vulnerability Details
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device.
Published CVE snapshot: 2026-10-22. Record last updated: 2025-11-11T20:20:22.924Z. The live panels refresh separately; this snapshot remains available if a source cannot be reached.
View the CVE Program source record
siemens · CVSS 3.1: 6.8 Medium
Calculated from the published vector. Base score: 6.8. Provider-reported Base score: 6.8.
Vector and metric explanations
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H| Metric | Value | Meaning |
|---|
| Attack vector (AV) | P | Requires physical access to or manipulation of the vulnerable component. |
| Attack complexity (AC) | L | Exploitation does not depend on special conditions beyond the attacker’s control. |
| Privileges required (PR) | N | The attacker needs no privileges before exploiting the vulnerability. |
| User interaction (UI) | N | No other user must participate for exploitation to succeed. |
| Scope (S) | U | Consequences stay within resources managed by the same security authority. |
| Confidentiality (C) | H | All information is disclosed, or a limited disclosure has a direct, serious confidentiality consequence. |
| Integrity (I) | H | Integrity is completely lost, or modification has a direct, serious consequence. |
| Availability (A) | H | Availability is completely lost, or the disruption has a direct, serious consequence. |
These definitions explain provider selections; they do not independently verify exploitation.
Review vector in calculatorsiemens · CVSS 4.0: 7.0 High
Calculated from the published vector. Base score: 7.0. Provider-reported Base score: 7.
Vector and metric explanations
CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N| Metric | Value | Meaning |
|---|
| Attack vector (AV) | P | Requires physical access to or manipulation of the vulnerable component. |
| Attack complexity (AC) | L | There is no specific security-enhancing condition that the attacker must overcome. |
| Attack requirements (AT) | N | No particular deployment or execution prerequisite is needed. |
| Privileges required (PR) | N | The attacker needs no privileges before exploiting the vulnerability. |
| User interaction (UI) | N | No other user must participate for exploitation to succeed. |
| Confidentiality (VC) | H | All information is disclosed, or a limited disclosure has a direct, serious confidentiality consequence. |
| Integrity (VI) | H | Integrity is completely lost, or modification has a direct, serious consequence. |
| Availability (VA) | H | Availability is completely lost, or the disruption has a direct, serious consequence. |
| Confidentiality (SC) | N | No impact to this property is established in a subsequent system. |
| Integrity (SI) | N | No impact to this property is established in a subsequent system. |
| Availability (SA) | N | No impact to this property is established in a subsequent system. |
These definitions explain provider selections; they do not independently verify exploitation.
Review vector in calculatorAffected products reported by the provider
- Siemens · SIPROTEC 5 6MD84 (CP300)
- Siemens · SIPROTEC 5 6MD85 (CP200)
- Siemens · SIPROTEC 5 6MD85 (CP300)
- Siemens · SIPROTEC 5 6MD86 (CP200)
- Siemens · SIPROTEC 5 6MD86 (CP300)
- Siemens · SIPROTEC 5 6MD89 (CP300)
- Siemens · SIPROTEC 5 6MU85 (CP300)
- Siemens · SIPROTEC 5 7KE85 (CP200)
- Siemens · SIPROTEC 5 7KE85 (CP300)
- Siemens · SIPROTEC 5 7SA82 (CP100)
- Siemens · SIPROTEC 5 7SA82 (CP150)
- Siemens · SIPROTEC 5 7SA86 (CP200)
- Siemens · SIPROTEC 5 7SA86 (CP300)
- Siemens · SIPROTEC 5 7SA87 (CP200)
- Siemens · SIPROTEC 5 7SA87 (CP300)
- Siemens · SIPROTEC 5 7SD82 (CP100)
- Siemens · SIPROTEC 5 7SD82 (CP150)
- Siemens · SIPROTEC 5 7SD86 (CP200)
- Siemens · SIPROTEC 5 7SD86 (CP300)
- Siemens · SIPROTEC 5 7SD87 (CP200)
- Siemens · SIPROTEC 5 7SD87 (CP300)
- Siemens · SIPROTEC 5 7SJ81 (CP100)
- Siemens · SIPROTEC 5 7SJ81 (CP150)
- Siemens · SIPROTEC 5 7SJ82 (CP100)
- Siemens · SIPROTEC 5 7SJ82 (CP150)
- Siemens · SIPROTEC 5 7SJ85 (CP200)
- Siemens · SIPROTEC 5 7SJ85 (CP300)
- Siemens · SIPROTEC 5 7SJ86 (CP200)
- Siemens · SIPROTEC 5 7SJ86 (CP300)
- Siemens · SIPROTEC 5 7SK82 (CP100)
- Siemens · SIPROTEC 5 7SK82 (CP150)
- Siemens · SIPROTEC 5 7SK85 (CP200)
- Siemens · SIPROTEC 5 7SK85 (CP300)
- Siemens · SIPROTEC 5 7SL82 (CP100)
- Siemens · SIPROTEC 5 7SL82 (CP150)
- Siemens · SIPROTEC 5 7SL86 (CP200)
- Siemens · SIPROTEC 5 7SL86 (CP300)
- Siemens · SIPROTEC 5 7SL87 (CP200)
- Siemens · SIPROTEC 5 7SL87 (CP300)
- Siemens · SIPROTEC 5 7SS85 (CP200)
- Siemens · SIPROTEC 5 7SS85 (CP300)
- Siemens · SIPROTEC 5 7ST85 (CP200)
- Siemens · SIPROTEC 5 7ST85 (CP300)
- Siemens · SIPROTEC 5 7ST86 (CP300)
- Siemens · SIPROTEC 5 7SX82 (CP150)
- Siemens · SIPROTEC 5 7SX85 (CP300)
- Siemens · SIPROTEC 5 7SY82 (CP150)
- Siemens · SIPROTEC 5 7UM85 (CP300)
- Siemens · SIPROTEC 5 7UT82 (CP100)
- Siemens · SIPROTEC 5 7UT82 (CP150)
- Siemens · SIPROTEC 5 7UT85 (CP200)
- Siemens · SIPROTEC 5 7UT85 (CP300)
- Siemens · SIPROTEC 5 7UT86 (CP200)
- Siemens · SIPROTEC 5 7UT86 (CP300)
- Siemens · SIPROTEC 5 7UT87 (CP200)
- Siemens · SIPROTEC 5 7UT87 (CP300)
- Siemens · SIPROTEC 5 7VE85 (CP300)
- Siemens · SIPROTEC 5 7VK87 (CP200)
- Siemens · SIPROTEC 5 7VK87 (CP300)
- Siemens · SIPROTEC 5 7VU85 (CP300)
- Siemens · SIPROTEC 5 Compact 7SX800 (CP050)
Consult the advisory for affected version ranges, configurations and remediation. A product listing alone does not establish that your installation is vulnerable.
Source references (1)
Interpret severity and exploitation separately
CVSS measures technical severity. EPSS estimates exploitation probability over the next 30 days. CISA KEV lists known exploited vulnerabilities. A missing EPSS result is not zero probability, and absence from KEV does not prove no exploitation. Review your deployment and retain the version, vector and evidence when documenting a finding.
Browse CVEs from 2024 · All published CVEs · Calculation methodology