CVE 2017 Directory: Page 451
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
14,765 published records with identifiers assigned to 2017. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 451 of 616
- CVE-2017-6055
Vulnerability Details
View details for CVE-2017-6055
XML external entity (XXE) vulnerability in eParakstitajs 3 before 1.3.9 and eParaksts Java lib before 2.5.13 allows remote attackers to read arbitrary files or possibly have unspecified other impact via a crafted edoc file.
Open full assessment ↗ - CVE-2017-6054
Vulnerability Details
View details for CVE-2017-6054
A Use of Hard-Coded Cryptographic Key issue was discovered in Hyundai Motor America Blue Link 3.9.5 and 3.9.4. The application uses a hard-coded decryption password to protect sensitive user information.
Open full assessment ↗ - CVE-2017-6053
Vulnerability Details
View details for CVE-2017-6053
A Cross-Site Scripting issue was discovered in Trihedral VTScada Versions prior to 11.2.26. A cross-site scripting vulnerability may allow JavaScript code supplied by the attacker to execute within the user's browser.
Open full assessment ↗ - CVE-2017-6052
Vulnerability Details
View details for CVE-2017-6052
A Man-in-the-Middle issue was discovered in Hyundai Motor America Blue Link 3.9.5 and 3.9.4. Communication channel endpoints are not verified, which may allow a remote attacker to access or influence communications between the identified endpoints.
Open full assessment ↗ - CVE-2017-6051
Vulnerability Details
View details for CVE-2017-6051
An Uncontrolled Search Path Element issue was discovered in BLF-Tech LLC VisualView HMI Version 9.9.14.0 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to run a malicious DLL file within the search path resulting in execution of arbitrary code.
Open full assessment ↗ - CVE-2017-6050
Vulnerability Details
View details for CVE-2017-6050
A SQL Injection issue was discovered in Ecava IntegraXor Versions 5.2.1231.0 and prior. The application fails to properly validate user input, which may allow for an unauthenticated attacker to remotely execute arbitrary code in the form of SQL queries.
Open full assessment ↗ - CVE-2017-6049
Vulnerability Details
View details for CVE-2017-6049
Detcon Sitewatch Gateway, all versions without cellular, an attacker can edit settings on the device using a specially crafted URL.
Open full assessment ↗ - CVE-2017-6048
Vulnerability Details
View details for CVE-2017-6048
A Command Injection issue was discovered in Satel Iberia SenNet Data Logger and Electricity Meters: SenNet Optimal DataLogger V5.37c-1.43c and prior, SenNet Solar Datalogger V5.03-1.56a and prior, and SenNet Multitask Meter V5.21a-1.18b and prior. Successful exploitation of this vulnerability could result in the attacker breaking out of the jailed shell and gaining full access to the system.
Open full assessment ↗ - CVE-2017-6047
Vulnerability Details
View details for CVE-2017-6047
Detcon Sitewatch Gateway, all versions without cellular, Passwords are presented in plaintext in a file that is accessible without authentication.
Open full assessment ↗ - CVE-2017-6046
Vulnerability Details
View details for CVE-2017-6046
An Insufficiently Protected Credentials issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Sensitive information is insufficiently protected during transmission and vulnerable to sniffing, which could lead to information disclosure.
Open full assessment ↗ - CVE-2017-6045
Vulnerability Details
View details for CVE-2017-6045
An Information Exposure issue was discovered in Trihedral VTScada Versions prior to 11.2.26. Some files are exposed within the web server application to unauthenticated users. These files may contain sensitive configuration information.
Open full assessment ↗ - CVE-2017-6044
Vulnerability Details
View details for CVE-2017-6044
An Improper Authorization issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Several files and directories can be accessed without authentication, which may allow a remote attacker to perform sensitive functions including arbitrary file upload, file download, and device reboot.
Open full assessment ↗ - CVE-2017-6043
Vulnerability Details
View details for CVE-2017-6043
A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available.
Open full assessment ↗ - CVE-2017-6042
Vulnerability Details
View details for CVE-2017-6042
A Cross-Site Request Forgery issue was discovered in Sierra Wireless AirLink Raven XE, all versions prior to 4.0.14, and AirLink Raven XT, all versions prior to 4.0.11. Affected devices do not verify if a request was intentionally sent by the logged-in user, which may allow an attacker to trick a client into making an unintentional request to the web server that will be treated as an authentic request.
Open full assessment ↗ - CVE-2017-6041
Vulnerability Details
View details for CVE-2017-6041
An Unrestricted Upload issue was discovered in Marel Food Processing Systems M3000 terminal associated with the following systems: A320, A325, A371, A520 Master, A520 Slave, A530, A542, A571, Check Bin Grader, FlowlineQC T376, IPM3 Dual Cam v132, IPM3 Dual Cam v139, IPM3 Single Cam v132, P520, P574, SensorX13 QC flow line, SensorX23 QC Master, SensorX23 QC Slave, Speed Batcher, T374, T377, V36, V36B, and V36C; M3210 terminal associated with the same systems as the M3000 terminal identified above; M3000 desktop software associated with the same systems as the M3000 terminal identified above; MAC4 controller associated with the same systems as the M3000 terminal identified above; SensorX23 X-ray machine; SensorX25 X-ray machine; and MWS2 weighing system. This vulnerability allows an attacker to modify the operation and upload firmware changes without detection.
Open full assessment ↗ - CVE-2017-6040
Vulnerability Details
View details for CVE-2017-6040
An Information Exposure issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. Non-sensitive information can be obtained anonymously.
Open full assessment ↗ - CVE-2017-6039
Vulnerability Details
View details for CVE-2017-6039
A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device.
Open full assessment ↗ - CVE-2017-6038
Vulnerability Details
View details for CVE-2017-6038
A Cross-Site Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web application does not sufficiently verify that requests were provided by the user who submitted the request.
Open full assessment ↗ - CVE-2017-6037
Vulnerability Details
View details for CVE-2017-6037
A Heap-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow when a maliciously crafted project file is run by the system.
Open full assessment ↗ - CVE-2017-6036
Vulnerability Details
View details for CVE-2017-6036
A Server-Side Request Forgery issue was discovered in Belden Hirschmann GECKO Lite Managed switch, Version 2.0.00 and prior versions. The web server receives a request, but does not sufficiently verify that the request is being sent to the expected destination.
Open full assessment ↗ - CVE-2017-6035
Vulnerability Details
View details for CVE-2017-6035
A Stack-Based Buffer Overflow issue was discovered in Wecon Technologies LEVI Studio HMI Editor before 1.8.1. This vulnerability causes a buffer overflow, which could result in denial of service when a malicious project file is run on the system.
Open full assessment ↗ - CVE-2017-6034
Schneider Electric Modicon Modbus Protocol Authentication Bypass by Capture-replay
View details for CVE-2017-6034
An authentication bypass by capture-replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2017-6033
Vulnerability Details
View details for CVE-2017-6033
A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path.
Open full assessment ↗ - CVE-2017-6032
Vulnerability Details
View details for CVE-2017-6032
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.
Open full assessment ↗