CVE 2017 Directory: Page 452
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
14,765 published records with identifiers assigned to 2017. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 452 of 616
- CVE-2017-6031
Vulnerability Details
View details for CVE-2017-6031
A Header Injection issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. An "improper neutralization of HTTP headers for scripting syntax" issue has been identified, which may allow remote code execution.
Open full assessment ↗ - CVE-2017-6030
Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
View details for CVE-2017-6030
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2017-6029
Vulnerability Details
View details for CVE-2017-6029
A Cross-Site Scripting issue was discovered in Certec EDV GmbH atvise scada prior to Version 3.0. This may allow remote code execution.
Open full assessment ↗ - CVE-2017-6028
Vulnerability Details
View details for CVE-2017-6028
An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application.
Open full assessment ↗ - CVE-2017-6027
Vulnerability Details
View details for CVE-2017-6027
An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A specially crafted web server request may allow the upload of arbitrary files (with a dangerous type) to the CODESYS Web Server without authorization which may allow remote code execution.
Open full assessment ↗ - CVE-2017-6026
Vulnerability Details
View details for CVE-2017-6026
A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
Open full assessment ↗ - CVE-2017-6025
Vulnerability Details
View details for CVE-2017-6025
A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious user could overflow the stack buffer by providing overly long strings to functions that handle the XML. Because the function does not verify string size before copying to memory, the attacker may then be able to crash the application or run arbitrary code.
Open full assessment ↗ - CVE-2017-6024
Vulnerability Details
View details for CVE-2017-6024
A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller.
Open full assessment ↗ - CVE-2017-6023
Vulnerability Details
View details for CVE-2017-6023
An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device.
Open full assessment ↗ - CVE-2017-6022
Vulnerability Details
View details for CVE-2017-6022
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
Open full assessment ↗ - CVE-2017-6021
Vulnerability Details
View details for CVE-2017-6021
In Schneider Electric ClearSCADA 2014 R1 (build 75.5210) and prior, 2014 R1.1 (build 75.5387) and prior, 2015 R1 (build 76.5648) and prior, and 2015 R2 (build 77.5882) and prior, an attacker with network access to the ClearSCADA server can send specially crafted sequences of commands and data packets to the ClearSCADA server that can cause the ClearSCADA server process and ClearSCADA communications driver processes to terminate. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).
Open full assessment ↗ - CVE-2017-6020
Vulnerability Details
View details for CVE-2017-6020
Leao Consultoria e Desenvolvimento de Sistemas (LCDS) LTDA ME LAquis SCADA software versions prior to version 4.1.0.3237 do not neutralize external input to ensure that users are not calling for absolute path sequences outside of their privilege level.
Open full assessment ↗ - CVE-2017-6019
Vulnerability Details
View details for CVE-2017-6019
An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.
Open full assessment ↗ - CVE-2017-6018
Vulnerability Details
View details for CVE-2017-6018
An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.
Open full assessment ↗ - CVE-2017-6017
Vulnerability Details
View details for CVE-2017-6017
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
Open full assessment ↗ - CVE-2017-6016
Vulnerability Details
View details for CVE-2017-6016
An Improper Access Control issue was discovered in LCDS - Leao Consultoria e Desenvolvimento de Sistemas LTDA ME LAquis SCADA. The following versions are affected: Versions 4.1 and prior versions released before January 20, 2017. An Improper Access Control vulnerability has been identified, which may allow an authenticated user to modify application files to escalate privileges.
Open full assessment ↗ - CVE-2017-6015
Vulnerability Details
View details for CVE-2017-6015
Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.
Open full assessment ↗ - CVE-2017-6014
Vulnerability Details
View details for CVE-2017-6014
In Wireshark 2.2.4 and earlier, a crafted or malformed STANAG 4607 capture file will cause an infinite loop and memory exhaustion. If the packet size field in a packet header is null, the offset to read from will not advance, causing continuous attempts to read the same zero length packet. This will quickly exhaust all system memory.
Open full assessment ↗ - CVE-2017-6013
Vulnerability Details
View details for CVE-2017-6013
Subrion CMS 4.0.5.10 has SQL injection in admin/database/ via the query parameter.
Open full assessment ↗ - CVE-2017-6011
Vulnerability Details
View details for CVE-2017-6011
An issue was discovered in icoutils 0.31.1. An out-of-bounds read leading to a buffer overflow was observed in the "simple_vec" function in the "extract.c" source file. This affects icotool.
Open full assessment ↗ - CVE-2017-6010
Vulnerability Details
View details for CVE-2017-6010
An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "extract_icons" function in the "extract.c" source file. This issue can be triggered by processing a corrupted ico file and will result in an icotool crash.
Open full assessment ↗ - CVE-2017-6009
Vulnerability Details
View details for CVE-2017-6009
An issue was discovered in icoutils 0.31.1. A buffer overflow was observed in the "decode_ne_resource_id" function in the "restable.c" source file. This is happening because the "len" parameter for memcpy is not checked for size and thus becomes a negative integer in the process, resulting in a failed memcpy. This affects wrestool.
Open full assessment ↗ - CVE-2017-6008
Vulnerability Details
View details for CVE-2017-6008
A kernel pool overflow in the driver hitmanpro37.sys in Sophos SurfRight HitmanPro before 3.7.20 Build 286 (included in the HitmanPro.Alert solution and Sophos Clean) allows local users to escalate privileges via a malformed IOCTL call.
Open full assessment ↗ - CVE-2017-6007
Vulnerability Details
View details for CVE-2017-6007
A kernel pool overflow in the driver hitmanpro37.sys in Sophos SurfRight HitmanPro before 3.7.20 Build 286 (included in the HitmanPro.Alert solution and Sophos Clean) allows local users to crash the OS via a malformed IOCTL call.
Open full assessment ↗