CVE 2018 Directory: Page 362
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
16,188 published records with identifiers assigned to 2018. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 362 of 675
- CVE-2018-10637
Vulnerability Details
View details for CVE-2018-10637
A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code that affects Fuji Electric V-Server Lite 4.0.3.0 and prior.
Open full assessment ↗ - CVE-2018-10636
Vulnerability Details
View details for CVE-2018-10636
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.
Open full assessment ↗ - CVE-2018-10635
Vulnerability Details
View details for CVE-2018-10635
In Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100, ports 30001/TCP to 30003/TCP listen for arbitrary URScript code and execute the code. This enables a remote attacker who has access to the ports to remotely execute code that may allow root access to be obtained.
Open full assessment ↗ - CVE-2018-10634
Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Cleartext Transmission of Sensitive Information
View details for CVE-2018-10634
Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-10633
Vulnerability Details
View details for CVE-2018-10633
Universal Robots Robot Controllers Version CB 3.1, SW Version 3.4.5-100 utilizes hard-coded credentials that may allow an attacker to reset passwords for the controller.
Open full assessment ↗ - CVE-2018-10632
Vulnerability Details
View details for CVE-2018-10632
In Moxa NPort 5210, 5230, and 5232 versions 2.9 build 17030709 and prior, the amount of resources requested by a malicious actor are not restricted, allowing for a denial-of-service condition.
Open full assessment ↗ - CVE-2018-10631
Medtronic N'Vision Clinician Programmer Protection Mechanism Failure
View details for CVE-2018-10631
The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and sufficient technical capability can modify the contents of this card, including the binary executables. If modified to bypass protection mechanisms, this malicious code will be run when the card is inserted into an 8840 Clinician Programmer.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-10630
Vulnerability Details
View details for CVE-2018-10630
For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3 version prior to 1.502.0047.001, The devices are shipped with authentication disabled, and there is no indication to users that they need to take steps to enable it. When compromised, the access to the CTP console is left open.
Open full assessment ↗ - CVE-2018-10628
Vulnerability Details
View details for CVE-2018-10628
AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2017 Update 1, and InTouch 2017 Update 2 allow an unauthenticated user to send a specially crafted packet that could overflow the buffer on a locale not using a dot floating point separator. Exploitation could allow remote code execution under the privileges of the InTouch View process.
Open full assessment ↗ - CVE-2018-10627
Vulnerability Details
View details for CVE-2018-10627
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can use the SOAP API to retrieve and change sensitive configuration items such as the usernames and passwords for the Web and FTP servers. This vulnerability does not affect the i.LON 600 product.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-10626
Medtronic MyCareLink 24950 Patient Monitor Insufficient Verification of Data Authenticity
View details for CVE-2018-10626
Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product credentials from the monitor and paired implantable cardiac device information can potentially upload invalid data to the Medtronic CareLink network.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-10624
Johnson Controls Metasys and BCPro Generation of Error Message Containing Sensitive Information
View details for CVE-2018-10624
In Johnson Controls Metasys System Versions 8.0 and prior and BCPro (BCM) all versions prior to 3.0.2, this vulnerability results from improper error handling in HTTP-based communications with the server, which could allow an attacker to obtain technical information.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-10623
Vulnerability Details
View details for CVE-2018-10623
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior performs read operations on a memory buffer where the position can be determined by a value read from a .dpa file. This may cause improper restriction of operations within the bounds of the memory buffer, allow remote code execution, alter the intended control flow, allow reading of sensitive information, or cause the application to crash.
Open full assessment ↗ - CVE-2018-10622
Medtronic MyCareLink Patient Monitor Network Credential Weakness
View details for CVE-2018-10622
Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication.
Medtronic · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-10621
Vulnerability Details
View details for CVE-2018-10621
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length stack buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash.
Open full assessment ↗ - CVE-2018-10620
Vulnerability Details
View details for CVE-2018-10620
AVEVA InduSoft Web Studio v8.1 and v8.1SP1, and InTouch Machine Edition v2017 8.1 and v2017 8.1 SP1 a remote user could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed.
Open full assessment ↗ - CVE-2018-10619
Vulnerability Details
View details for CVE-2018-10619
An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.
Open full assessment ↗ - CVE-2018-10618
Vulnerability Details
View details for CVE-2018-10618
Davolink DVW-3200N all version prior to Version 1.00.06. The device generates a weak password hash that is easily cracked, allowing a remote attacker to obtain the password for the device.
Open full assessment ↗ - CVE-2018-10617
Vulnerability Details
View details for CVE-2018-10617
Delta Electronics Delta Industrial Automation DOPSoft version 4.00.04 and prior utilizes a fixed-length heap buffer where a value larger than the buffer can be read from a .dpa file into the buffer, causing the buffer to be overwritten. This may allow remote code execution or cause the application to crash.
Open full assessment ↗ - CVE-2018-10616
Vulnerability Details
View details for CVE-2018-10616
ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.
Open full assessment ↗ - CVE-2018-10615
Vulnerability Details
View details for CVE-2018-10615
Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.
Open full assessment ↗ - CVE-2018-10614
Vulnerability Details
View details for CVE-2018-10614
An XXE vulnerability in LeviStudioU, Versions 1.8.29 and 1.8.44 can be exploited when the application processes specially crafted project XML files.
Open full assessment ↗ - CVE-2018-10613
Vulnerability Details
View details for CVE-2018-10613
Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.
Open full assessment ↗ - CVE-2018-10612
Vulnerability Details
View details for CVE-2018-10612
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.
Open full assessment ↗