CVE 2018 Directory: Page 363
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
16,188 published records with identifiers assigned to 2018. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 363 of 675
- CVE-2018-10611
Vulnerability Details
View details for CVE-2018-10611
Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.
Open full assessment ↗ - CVE-2018-10610
Vulnerability Details
View details for CVE-2018-10610
An out-of-bounds vulnerability in LeviStudioU, Versions 1.8.29 and 1.8.44 can be exploited when the application processes specially crafted project files.
Open full assessment ↗ - CVE-2018-10609
Vulnerability Details
View details for CVE-2018-10609
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow improper sanitization of data over a Websocket which may allow cross-site scripting and client-side code execution with target user privileges.
Open full assessment ↗ - CVE-2018-10608
Vulnerability Details
View details for CVE-2018-10608
SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required.
Open full assessment ↗ - CVE-2018-10607
Vulnerability Details
View details for CVE-2018-10607
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow the creation of new connections to one or more IOAs, without closing them properly, which may cause a denial of service within the industrial process control channel.
Open full assessment ↗ - CVE-2018-10606
Vulnerability Details
View details for CVE-2018-10606
WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple heap-based buffer overflow vulnerabilities that can be exploited when the application processes specially crafted project files.
Open full assessment ↗ - CVE-2018-10605
Vulnerability Details
View details for CVE-2018-10605
Martem TELEM GW6/GWM versions prior to 2.0.87-4018403-k4 may allow unprivileged users to modify/upload a new system configuration or take the full control over the RTU using default credentials to connect to the RTU.
Open full assessment ↗ - CVE-2018-10604
Vulnerability Details
View details for CVE-2018-10604
SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwriting of files within the Compass installation folder, resulting in escalation of privilege and/or malicious code execution.
Open full assessment ↗ - CVE-2018-10603
Vulnerability Details
View details for CVE-2018-10603
Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commands, which may allow a rogue node a remote control of the industrial process.
Open full assessment ↗ - CVE-2018-10602
Vulnerability Details
View details for CVE-2018-10602
WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple stack-based buffer overflow vulnerabilities that can be exploited when the application processes specially crafted project files.
Open full assessment ↗ - CVE-2018-10601
Vulnerability Details
View details for CVE-2018-10601
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.
Open full assessment ↗ - CVE-2018-10600
Vulnerability Details
View details for CVE-2018-10600
SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks.
Open full assessment ↗ - CVE-2018-10599
Vulnerability Details
View details for CVE-2018-10599
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
Open full assessment ↗ - CVE-2018-10598
Vulnerability Details
View details for CVE-2018-10598
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.
Open full assessment ↗ - CVE-2018-10597
Vulnerability Details
View details for CVE-2018-10597
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.
Open full assessment ↗ - CVE-2018-10596
Medtronic 2090 Carelink Programmer Improper Restriction of Communication Channel to Intended Endpoints
View details for CVE-2018-10596
Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still connected to this virtual private network before downloading updates. The affected products initially establish an encapsulated IP-based VPN connection to a Medtronic-hosted update network. Once the VPN is established, it makes a request to a HTTP (non-TLS) server across the VPN for updates, which responds and provides any available updates. The programmer-side (client) service responsible for this HTTP request does not check to ensure it is still connected to the VPN before making the HTTP request. Thus, an attacker could cause the VPN connection to terminate (through various methods and attack points) and intercept the HTTP request, responding with malicious updates via a man-in-the-middle attack. The affected products do not verify the origin or integrity of these updates, as it insufficiently relied on the security of the VPN. An attacker with remote network access to the programmer could influence these communications.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-10595
Vulnerability Details
View details for CVE-2018-10595
A vulnerability in ReadA version 1.1.0.2 and previous allows an authorized user with access to a privileged account on a BD Kiestra system (Kiestra TLA, Kiestra WCA, and InoqulA+ specimen processor) to issue SQL commands, which may result in loss or corruption of data.
Open full assessment ↗ - CVE-2018-10594
Vulnerability Details
View details for CVE-2018-10594
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
Open full assessment ↗ - CVE-2018-10593
Vulnerability Details
View details for CVE-2018-10593
A vulnerability in DB Manager version 3.0.1.0 and previous and PerformA version 3.0.0.0 and previous allows an authorized user with access to a privileged account on a BD Kiestra system (Kiestra TLA, Kiestra WCA, and InoqulA+ specimen processor) to issue SQL commands, which may result in data corruption.
Open full assessment ↗ - CVE-2018-10592
Vulnerability Details
View details for CVE-2018-10592
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
Open full assessment ↗ - CVE-2018-10591
Vulnerability Details
View details for CVE-2018-10591
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an origin validation error vulnerability has been identified, which may allow an attacker can create a malicious web site, steal session cookies, and access data of authenticated users.
Open full assessment ↗ - CVE-2018-10590
Vulnerability Details
View details for CVE-2018-10590
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an information exposure vulnerability through directory listing has been identified, which may allow an attacker to find important files that are not normally visible.
Open full assessment ↗ - CVE-2018-10589
Vulnerability Details
View details for CVE-2018-10589
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a path transversal vulnerability has been identified, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2018-10587
Vulnerability Details
View details for CVE-2018-10587
NetGain Enterprise Manager (EM) is affected by OS Command Injection vulnerabilities in versions before 10.0.57. These vulnerabilities could allow remote authenticated attackers to inject arbitrary code, resulting in remote code execution.
Open full assessment ↗