CVE 2018 Directory: Page 409
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
16,188 published records with identifiers assigned to 2018. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 409 of 675
- CVE-2018-8854
Vulnerability Details
View details for CVE-2018-8854
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended.
Open full assessment ↗ - CVE-2018-8853
Vulnerability Details
View details for CVE-2018-8853
Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. Windows boots by default with elevated Windows privileges, enabling a kiosk application, user, or an attacker to potentially attain unauthorized elevated privileges in Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior. Also, attackers may gain access to unauthorized resources from the underlying Windows operating system.
Open full assessment ↗ - CVE-2018-8852
Vulnerability Details
View details for CVE-2018-8852
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier.
Open full assessment ↗ - CVE-2018-8851
Vulnerability Details
View details for CVE-2018-8851
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-8850
Vulnerability Details
View details for CVE-2018-8850
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result in altered control flow, arbitrary control of a resource, or arbitrary code execution.
Open full assessment ↗ - CVE-2018-8849
Medtronic N'Vision Clinician Programmer Missing Encryption of Sensitive Data
View details for CVE-2018-8849
Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-8848
Vulnerability Details
View details for CVE-2018-8848
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.
Open full assessment ↗ - CVE-2018-8847
Vulnerability Details
View details for CVE-2018-8847
Eaton 9000X DriveA versions 2.0.29 and prior has a stack-based buffer overflow vulnerability, which may allow remote code execution.
Open full assessment ↗ - CVE-2018-8846
Vulnerability Details
View details for CVE-2018-8846
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users.
Open full assessment ↗ - CVE-2018-8845
Vulnerability Details
View details for CVE-2018-8845
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a heap-based buffer overflow vulnerability has been identified, which may allow an attacker to execute arbitrary code.
Open full assessment ↗ - CVE-2018-8844
Vulnerability Details
View details for CVE-2018-8844
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.
Open full assessment ↗ - CVE-2018-8843
Vulnerability Details
View details for CVE-2018-8843
Rockwell Automation Arena versions 15.10.00 and prior contains a use after free vulnerability caused by processing specially crafted Arena Simulation Software files that may cause the software application to crash, potentially losing any unsaved data..
Open full assessment ↗ - CVE-2018-8842
Vulnerability Details
View details for CVE-2018-8842
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet.
Open full assessment ↗ - CVE-2018-8841
Vulnerability Details
View details for CVE-2018-8841
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, an improper privilege management vulnerability may allow an authenticated user to modify files when read access should only be given to the user.
Open full assessment ↗ - CVE-2018-8840
Vulnerability Details
View details for CVE-2018-8840
A remote attacker could send a carefully crafted packet in InduSoft Web Studio v8.1 and prior versions, and/or InTouch Machine Edition 2017 v8.1 and prior versions during a tag, alarm, or event related action such as read and write, which may allow remote code execution.
Open full assessment ↗ - CVE-2018-8839
Vulnerability Details
View details for CVE-2018-8839
Delta PMSoft versions 2.10 and prior have multiple stack-based buffer overflow vulnerabilities where a .ppm file can introduce a value larger than is readable by PMSoft's fixed-length stack buffer. This can cause the buffer to be overwritten, which may allow arbitrary code execution or cause the application to crash. CVSS v3 base score: 7.1; CVSS vector string: AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H. Delta Electronics recommends affected users update to at least PMSoft v2.11, which was made available as of March 22, 2018, or the latest available version.
Open full assessment ↗ - CVE-2018-8838
Vulnerability Details
View details for CVE-2018-8838
A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CENTUM VP versions R6.03.10 and earlier, CENTUM VP Small versions R6.03.10 and earlier, CENTUM VP Basic versions R6.03.10 and earlier, Exaopc versions R3.75.00 and earlier, B/M9000 CS all versions, and B/M9000 VP versions R8.01.01 and earlier may allow a local attacker to exploit the message management function of the system. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H).
Open full assessment ↗ - CVE-2018-8837
Vulnerability Details
View details for CVE-2018-8837
Processing specially crafted .pm3 files in Advantech WebAccess HMI Designer 2.1.7.32 and prior may cause the system to write outside the intended buffer area and may allow remote code execution.
Open full assessment ↗ - CVE-2018-8836
Vulnerability Details
View details for CVE-2018-8836
Wago 750 Series PLCs with firmware version 10 and prior include a remote attack may take advantage of an improper implementation of the 3 way handshake during a TCP connection affecting the communications with commission and service tools. Specially crafted packets may also be sent to Port 2455/TCP/IP, used in Codesys management software, which may result in a denial-of-service condition of communications with commissioning and service tools.
Open full assessment ↗ - CVE-2018-8835
Vulnerability Details
View details for CVE-2018-8835
Double free vulnerabilities in Advantech WebAccess HMI Designer 2.1.7.32 and prior caused by processing specially crafted .pm3 files may allow remote code execution.
Open full assessment ↗ - CVE-2018-8834
Vulnerability Details
View details for CVE-2018-8834
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a heap-based buffer overflow.
Open full assessment ↗ - CVE-2018-8833
Vulnerability Details
View details for CVE-2018-8833
Heap-based buffer overflow vulnerabilities in Advantech WebAccess HMI Designer 2.1.7.32 and prior caused by processing specially crafted .pm3 files may allow remote code execution.
Open full assessment ↗ - CVE-2018-8832
Vulnerability Details
View details for CVE-2018-8832
enhavo 0.4.0 has XSS via a user-group that contains executable JavaScript code in the user-group name. The XSS attack launches when a victim visits the admin user group page.
Open full assessment ↗ - CVE-2018-8831
Vulnerability Details
View details for CVE-2018-8831
A Persistent XSS vulnerability exists in Kodi (formerly XBMC) through 17.6 that allows the execution of arbitrary HTML/script code in the context of the victim user's browser via a playlist.
Open full assessment ↗