CVE 2018 Directory: Page 408
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
16,188 published records with identifiers assigned to 2018. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 408 of 675
- CVE-2018-8878
Vulnerability Details
View details for CVE-2018-8878
Information disclosure in Asuswrt-Merlin firmware for ASUS devices older than 384.4 and ASUS firmware before 3.0.0.4.382.50470 for devices allows remote attackers to acquire information on internal network devices' hostnames and MAC addresses by reading the custom_id variable on the blocking.asp page.
Open full assessment ↗ - CVE-2018-8877
Vulnerability Details
View details for CVE-2018-8877
Information disclosure in Asuswrt-Merlin firmware for ASUS devices older than 384.4 and ASUS firmware before 3.0.0.4.382.50470 for devices allows remote attackers to acquire information on internal network IP address ranges by reading the new_lan_ip variable on the error_page.htm page.
Open full assessment ↗ - CVE-2018-8876
Vulnerability Details
View details for CVE-2018-8876
In 2345 Security Guard 3.6, the driver file (2345Wrath.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x00222098.
Open full assessment ↗ - CVE-2018-8875
Vulnerability Details
View details for CVE-2018-8875
In 2345 Security Guard 3.6, the driver file (2345Wrath.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x0022209c.
Open full assessment ↗ - CVE-2018-8874
Vulnerability Details
View details for CVE-2018-8874
In 2345 Security Guard 3.6, the driver file (2345Wrath.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x00222054.
Open full assessment ↗ - CVE-2018-8873
Vulnerability Details
View details for CVE-2018-8873
In 2345 Security Guard 3.6, the driver file (2345NetFirewall.sys) allows local users to cause a denial of service (BSOD) or possibly have unspecified other impact because of not validating input values from IOCtl 0x00222040.
Open full assessment ↗ - CVE-2018-8872
Vulnerability Details
View details for CVE-2018-8872
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
Open full assessment ↗ - CVE-2018-8871
Vulnerability Details
View details for CVE-2018-8871
In Delta Electronics Automation TPEditor version 1.89 or prior, parsing a malformed program file may cause heap-based buffer overflow vulnerability, which may allow remote code execution.
Open full assessment ↗ - CVE-2018-8870
Medtronic MyCareLink Patient Monitor Use of Hard-coded Password
View details for CVE-2018-8870
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-8869
Vulnerability Details
View details for CVE-2018-8869
In Lantech IDS 2102 2.0 and prior, nearly all input fields allow for arbitrary input on the device. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Open full assessment ↗ - CVE-2018-8868
Medtronic MyCareLink Patient Monitor Exposed Dangerous Method or Function
View details for CVE-2018-8868
Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, including the interface between the monitor and implantable cardiac device. An attacker with physical access to the device can exploit other vulnerabilities to access this debug functionality. This debug functionality provides the ability to read and write arbitrary memory values to implantable cardiac devices via inductive or short range wireless protocols. An attacker with close physical proximity to a target implantable cardiac device can use this debug functionality.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-8867
Vulnerability Details
View details for CVE-2018-8867
In GE PACSystems RX3i CPE305/310 version 9.20 and prior, RX3i CPE330 version 9.21 and prior, RX3i CPE 400 version 9.30 and prior, PACSystems RSTi-EP CPE 100 all versions, and PACSystems CPU320/CRU320 RXi all versions, the device does not properly validate input, which could allow a remote attacker to send specially crafted packets causing the device to become unavailable.
Open full assessment ↗ - CVE-2018-8866
Vulnerability Details
View details for CVE-2018-8866
In Vecna VGo Robot versions prior to 3.0.3.52164, an attacker on an adjacent network could perform command injection.
Open full assessment ↗ - CVE-2018-8865
Vulnerability Details
View details for CVE-2018-8865
In Lantech IDS 2102 2.0 and prior, a stack-based buffer overflow vulnerability has been identified which may allow remote code execution. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Open full assessment ↗ - CVE-2018-8864
Vulnerability Details
View details for CVE-2018-8864
In ATI Systems Emergency Mass Notification Systems (HPSS16, HPSS32, MHPSS, and ALERT4000) devices, a missing encryption of sensitive data vulnerability caused by specially crafted malicious radio transmissions may allow an attacker to remotely trigger false alarms.
Open full assessment ↗ - CVE-2018-8863
Philips EncoreAnywhere Exposure of Sensitive Information to an Unauthorized Actor
View details for CVE-2018-8863
The HTTP header in Philips EncoreAnywhere contains data an attacker may be able to use to gain sensitive information.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-8862
Vulnerability Details
View details for CVE-2018-8862
In ATI Systems Emergency Mass Notification Systems (HPSS16, HPSS32, MHPSS, and ALERT4000) devices, an improper authentication vulnerability caused by specially crafted malicious radio transmissions may allow an attacker to remotely trigger false alarms.
Open full assessment ↗ - CVE-2018-8861
Vulnerability Details
View details for CVE-2018-8861
Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) could enable a limited-access kiosk user or an unauthorized attacker to break-out from the containment of the kiosk environment, attain elevated privileges from the underlying Windows OS, and access unauthorized resources from the operating system.
Open full assessment ↗ - CVE-2018-8860
Vulnerability Details
View details for CVE-2018-8860
In Vecna VGo Robot versions prior to 3.0.3.52164, an attacker may be able to capture firmware updates through the adjacent network.
Open full assessment ↗ - CVE-2018-8859
Vulnerability Details
View details for CVE-2018-8859
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. An attacker can bypass the required authentication specified in the security configuration file by including extra characters in the directory name when specifying the directory to be accessed. This vulnerability does not affect the i.LON 600 product.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2018-8858
Vulnerability Details
View details for CVE-2018-8858
If an attacker has access to the firmware from the VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) they may be able to extract credentials.
Open full assessment ↗ - CVE-2018-8857
Vulnerability Details
View details for CVE-2018-8857
Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.
Open full assessment ↗ - CVE-2018-8856
Vulnerability Details
View details for CVE-2018-8856
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal data.
Open full assessment ↗ - CVE-2018-8855
Vulnerability Details
View details for CVE-2018-8855
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗