CVE 2019 Directory: Page 247
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
16,098 published records with identifiers assigned to 2019. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 247 of 671
- CVE-2019-13562
Vulnerability Details
View details for CVE-2019-13562
D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter.
Open full assessment ↗ - CVE-2019-13561
Vulnerability Details
View details for CVE-2019-13561
D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter.
Open full assessment ↗ - CVE-2019-13560
Vulnerability Details
View details for CVE-2019-13560
D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter.
Open full assessment ↗ - CVE-2019-13559
Vulnerability Details
View details for CVE-2019-13559
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.
Open full assessment ↗ - CVE-2019-13558
Vulnerability Details
View details for CVE-2019-13558
In WebAccess versions 8.4.1 and prior, an exploit executed over the network may cause improper control of generation of code, which may allow remote code execution, data exfiltration, or cause a system crash.
Open full assessment ↗ - CVE-2019-13557
Vulnerability Details
View details for CVE-2019-13557
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information.
Open full assessment ↗ - CVE-2019-13556
Vulnerability Details
View details for CVE-2019-13556
In WebAccess versions 8.4.1 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
Open full assessment ↗ - CVE-2019-13555
Vulnerability Details
View details for CVE-2019-13555
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.
Open full assessment ↗ - CVE-2019-13554
Vulnerability Details
View details for CVE-2019-13554
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service.
Open full assessment ↗ - CVE-2019-13553
Vulnerability Details
View details for CVE-2019-13553
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.
Open full assessment ↗ - CVE-2019-13552
Vulnerability Details
View details for CVE-2019-13552
In WebAccess versions 8.4.1 and prior, multiple command injection vulnerabilities are caused by a lack of proper validation of user-supplied data and may allow arbitrary file deletion and remote code execution.
Open full assessment ↗ - CVE-2019-13551
Vulnerability Details
View details for CVE-2019-13551
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. Path traversal vulnerabilities are caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage these vulnerabilities to remotely execute code while posing as an administrator.
Open full assessment ↗ - CVE-2019-13550
Vulnerability Details
View details for CVE-2019-13550
In WebAccess, versions 8.4.1 and prior, an improper authorization vulnerability may allow an attacker to disclose sensitive information, cause improper control of generation of code, which may allow remote code execution or cause a system crash.
Open full assessment ↗ - CVE-2019-13549
Vulnerability Details
View details for CVE-2019-13549
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
Open full assessment ↗ - CVE-2019-13548
Vulnerability Details
View details for CVE-2019-13548
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.
Open full assessment ↗ - CVE-2019-13547
Vulnerability Details
View details for CVE-2019-13547
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
Open full assessment ↗ - CVE-2019-13546
Vulnerability Details
View details for CVE-2019-13546
In IntelliSpace Perinatal, Versions K and prior, a vulnerability within the IntelliSpace Perinatal application environment could enable an unauthorized attacker with physical access to a locked application screen, or an authorized remote desktop session host application user to break-out from the containment of the application and access unauthorized resources from the Windows operating system as the limited-access Windows user. Due to potential Windows vulnerabilities, it may be possible for additional attack methods to be used to escalate privileges on the operating system.
Open full assessment ↗ - CVE-2019-13545
Vulnerability Details
View details for CVE-2019-13545
In Horner Automation Cscape 9.90 and prior, improper validation of data may cause the system to write outside the intended buffer area, which may allow arbitrary code execution.
Open full assessment ↗ - CVE-2019-13544
Vulnerability Details
View details for CVE-2019-13544
Delta Electronics TPEditor, Versions 1.94 and prior. Multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files, which may allow remote code execution.
Open full assessment ↗ - CVE-2019-13543
Medtronic Valleylab FT10 and FX8 Use of Hard-coded Credentials
View details for CVE-2019-13543
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use multiple sets of hard-coded credentials. If discovered, they can be used to read files on the device.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2019-13542
Vulnerability Details
View details for CVE-2019-13542
3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition.
Open full assessment ↗ - CVE-2019-13541
Vulnerability Details
View details for CVE-2019-13541
In Horner Automation Cscape 9.90 and prior, an improper input validation vulnerability has been identified that may be exploited by processing files lacking user input validation. This may allow an attacker to access information and remotely execute arbitrary code.
Open full assessment ↗ - CVE-2019-13540
Vulnerability Details
View details for CVE-2019-13540
Delta Electronics TPEditor, Versions 1.94 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code.
Open full assessment ↗ - CVE-2019-13539
Medtronic Valleylab FT10 and FX8 Reversible One-way Hash
View details for CVE-2019-13539
Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energy Platform (VLFX8GEN) software version 1.1.0 and below use the descrypt algorithm for OS password hashing. While interactive, network-based logons are disabled, and attackers can use the other vulnerabilities within this report to obtain local shell access and access these hashes.
icscert · Calculated from the published vector.
Open full assessment ↗