CVE 2019 Directory: Page 248
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
16,098 published records with identifiers assigned to 2019. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 248 of 671
- CVE-2019-13538
Vulnerability Details
View details for CVE-2019-13538
3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only.
Open full assessment ↗ - CVE-2019-13537
Vulnerability Details
View details for CVE-2019-13537
The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.
Open full assessment ↗ - CVE-2019-13536
Vulnerability Details
View details for CVE-2019-13536
Delta Electronics TPEditor, Versions 1.94 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code.
Open full assessment ↗ - CVE-2019-13535
Medtronic Valleylab FT10 and LS10 Protection Mechanism Failure
View details for CVE-2019-13535
In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism does not apply read protection, allowing for full read access of the RFID security mechanism data.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2019-13534
Vulnerability Details
View details for CVE-2019-13534
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code.
Open full assessment ↗ - CVE-2019-13533
Vulnerability Details
View details for CVE-2019-13533
In Omron PLC CJ series, all versions, and Omron PLC CS series, all versions, an attacker could monitor traffic between the PLC and the controller and replay requests that could result in the opening and closing of industrial valves.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2019-13532
Vulnerability Details
View details for CVE-2019-13532
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.
Open full assessment ↗ - CVE-2019-13531
Medtronic Valleylab FT10 and LS10 Improper Authentication
View details for CVE-2019-13531
In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not available in the United States) version 1.20.2 and lower, the RFID security mechanism used for authentication between the FT10/LS10 Energy Platform and instruments can be bypassed, allowing for inauthentic instruments to connect to the generator.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2019-13530
Vulnerability Details
View details for CVE-2019-13530
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware.
Open full assessment ↗ - CVE-2019-13529
Vulnerability Details
View details for CVE-2019-13529
An attacker could send a malicious link to an authenticated operator, which may allow remote attackers to perform actions with the permissions of the user on the Sunny WebBox Firmware Version 1.6 and prior. This device uses IP addresses to maintain communication after a successful login, which would increase the ease of exploitation.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2019-13528
Vulnerability Details
View details for CVE-2019-13528
A specific utility may allow an attacker to gain read access to privileged files in the Niagara AX 3.8u4 (JACE 3e, JACE 6e, JACE 7, JACE-8000), Niagara 4.4u3 (JACE 3e, JACE 6e, JACE 7, JACE-8000), and Niagara 4.7u1 (JACE-8000, Edge 10).
Open full assessment ↗ - CVE-2019-13527
Vulnerability Details
View details for CVE-2019-13527
In Rockwell Automation Arena Simulation Software Cat. 9502-Ax, Versions 16.00.00 and earlier, a maliciously crafted Arena file opened by an unsuspecting user may result in the use of a pointer that has not been initialized.
Open full assessment ↗ - CVE-2019-13526
Vulnerability Details
View details for CVE-2019-13526
Datalogic AV7000 Linear barcode scanner all versions prior to 4.6.0.0 is vulnerable to authentication bypass, which may allow an attacker to remotely execute arbitrary code.
Open full assessment ↗ - CVE-2019-13525
Vulnerability Details
View details for CVE-2019-13525
In IP-AK2 Access Control Panel Version 1.04.07 and prior, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data, which can be accessed without authentication over the network.
Open full assessment ↗ - CVE-2019-13524
Vulnerability Details
View details for CVE-2019-13524
GE PACSystems RX3i CPE100/115: All versions prior to R9.85,CPE302/305/310/330/400/410: All versions prior to R9.90,CRU/320 All versions(End of Life) may allow an attacker sending specially manipulated packets to cause the module state to change to halt-mode, resulting in a denial-of-service condition. An operator must reboot the CPU module after removing battery or energy pack to recover from halt-mode.
Open full assessment ↗ - CVE-2019-13523
Vulnerability Details
View details for CVE-2019-13523
In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L.
Open full assessment ↗ - CVE-2019-13522
Vulnerability Details
View details for CVE-2019-13522
An attacker could use a specially crafted project file to corrupt the memory and execute code under the privileges of the EZ PLC Editor Versions 1.8.41 and prior.
Open full assessment ↗ - CVE-2019-13521
Vulnerability Details
View details for CVE-2019-13521
A maliciously crafted program file opened by an unsuspecting user of Rockwell Automation Arena Simulation Software version 16.00.00 and earlier may result in the limited exposure of information related to the targeted workstation. Rockwell Automation has released version 16.00.01 of Arena Simulation Software to address the reported vulnerabilities.
Open full assessment ↗ - CVE-2019-13520
Vulnerability Details
View details for CVE-2019-13520
Multiple buffer overflow issues have been identified in Alpha5 Smart Loader: All versions prior to 4.2. An attacker could use specially crafted project files to overflow the buffer and execute code under the privileges of the application.
Open full assessment ↗ - CVE-2019-13519
Vulnerability Details
View details for CVE-2019-13519
A maliciously crafted program file opened by an unsuspecting user of Rockwell Automation Arena Simulation Software version 16.00.00 and earlier may result in the limited exposure of information related to the targeted workstation. Rockwell Automation has released version 16.00.01 of Arena Simulation Software to address the reported vulnerabilities.
Open full assessment ↗ - CVE-2019-13518
Vulnerability Details
View details for CVE-2019-13518
An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the EZ Touch Editor Versions 2.1.0 and prior.
Open full assessment ↗ - CVE-2019-13517
Vulnerability Details
View details for CVE-2019-13517
In Pyxis ES Versions 1.3.4 through to 1.6.1 and Pyxis Enterprise Server, with Windows Server Versions 4.4 through 4.12, a vulnerability has been identified where existing access privileges are not restricted in coordination with the expiration of access based on active directory user account changes when the device is joined to an AD domain.
Open full assessment ↗ - CVE-2019-13516
Vulnerability Details
View details for CVE-2019-13516
In OSIsoft PI Web API and prior, the affected product is vulnerable to a direct attack due to a cross-site request forgery protection setting that has not taken effect.
Open full assessment ↗ - CVE-2019-13515
Vulnerability Details
View details for CVE-2019-13515
OSIsoft PI Web API 2018 and prior may allow disclosure of sensitive information.
Open full assessment ↗