- CVE-2019-6572
Vulnerability Details
View details for CVE-2019-6572
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Open full assessment ↗ - CVE-2019-6571
Vulnerability Details
View details for CVE-2019-6571
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). An attacker with network access to port 10005/tcp of the LOGO! device could cause a Denial-of-Service condition by sending specially crafted packets. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Open full assessment ↗ - CVE-2019-6570
Vulnerability Details
View details for CVE-2019-6570
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Due to insufficient checking of user permissions, an attacker may access URLs that require special authorization. An attacker must have access to a low privileged account in order to exploit the vulnerability.
Open full assessment ↗ - CVE-2019-6569
Vulnerability Details
View details for CVE-2019-6569
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
Open full assessment ↗ - CVE-2019-6568
Vulnerability Details
View details for CVE-2019-6568
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
siemens · Calculated from the published vector.
Open full assessment ↗ - CVE-2019-6567
Vulnerability Details
View details for CVE-2019-6567
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.
Open full assessment ↗ - CVE-2019-6566
Vulnerability Details
View details for CVE-2019-6566
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to replace the uninstaller with a malicious version, which could allow an attacker to gain administrator privileges to the system.
Open full assessment ↗ - CVE-2019-6565
Vulnerability Details
View details for CVE-2019-6565
Moxa IKS and EDS fails to properly validate user input, giving unauthenticated and authenticated attackers the ability to perform XSS attacks, which may be used to send a malicious script.
Open full assessment ↗ - CVE-2019-6564
Vulnerability Details
View details for CVE-2019-6564
GE Communicator, all versions prior to 4.0.517, allows a non-administrative user to place malicious files within the installer file directory, which may allow an attacker to gain administrative privileges on a system during installation or upgrade.
Open full assessment ↗ - CVE-2019-6563
Vulnerability Details
View details for CVE-2019-6563
Moxa IKS and EDS generate a predictable cookie calculated with an MD5 hash, allowing an attacker to capture the administrator's password, which could lead to a full compromise of the device.
Open full assessment ↗ - CVE-2019-6562
Vulnerability Details
View details for CVE-2019-6562
In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
Open full assessment ↗ - CVE-2019-6561
Vulnerability Details
View details for CVE-2019-6561
Cross-site request forgery has been identified in Moxa IKS and EDS, which may allow for the execution of unauthorized actions on the device.
Open full assessment ↗ - CVE-2019-6560
Vulnerability Details
View details for CVE-2019-6560
In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.
Open full assessment ↗ - CVE-2019-6559
Vulnerability Details
View details for CVE-2019-6559
Moxa IKS and EDS allow remote authenticated users to cause a denial of service via a specially crafted packet, which may cause the switch to crash.
Open full assessment ↗ - CVE-2019-6558
Vulnerability Details
View details for CVE-2019-6558
In Auto-Maskin RP210E Versions 3.7 and prior, DCU210E Versions 3.7 and prior and Marine Observer Pro (Android App), the software contains a mechanism for users to recover or change their passwords without knowing the original password, but the mechanism is weak.
Open full assessment ↗ - CVE-2019-6557
Vulnerability Details
View details for CVE-2019-6557
Several buffer overflow vulnerabilities have been identified in Moxa IKS and EDS, which may allow remote code execution.
Open full assessment ↗ - CVE-2019-6556
Vulnerability Details
View details for CVE-2019-6556
When processing project files, the application (Omron CX-Programmer v9.70 and prior and Common Components January 2019 and prior) fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.
Open full assessment ↗ - CVE-2019-6555
Vulnerability Details
View details for CVE-2019-6555
Cscape, 9.80 SP4 and prior. An improper input validation vulnerability may be exploited by processing specially crafted POC files. This may allow an attacker to read confidential information and remotely execute arbitrary code.
Open full assessment ↗ - CVE-2019-6554
Vulnerability Details
View details for CVE-2019-6554
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. An improper access control vulnerability may allow an attacker to cause a denial-of-service condition.
Open full assessment ↗ - CVE-2019-6553
Vulnerability Details
View details for CVE-2019-6553
A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition.
Open full assessment ↗ - CVE-2019-6552
Vulnerability Details
View details for CVE-2019-6552
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.
Open full assessment ↗ - CVE-2019-6551
Vulnerability Details
View details for CVE-2019-6551
Pangea Communications Internet FAX ATA all Versions 3.1.8 and prior allow an attacker to bypass user authentication using a specially crafted URL to cause the device to reboot, which may be used to cause a continual denial-of-service condition.
Open full assessment ↗ - CVE-2019-6550
Vulnerability Details
View details for CVE-2019-6550
Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple stack-based buffer overflow vulnerabilities, caused by a lack of proper validation of the length of user-supplied data, may allow remote code execution.
Open full assessment ↗ - CVE-2019-6549
Vulnerability Details
View details for CVE-2019-6549
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP.