CVE 2020 Directory: Page 166
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
19,402 published records with identifiers assigned to 2020. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 166 of 809
- CVE-2020-25200
Vulnerability Details
View details for CVE-2020-25200
Pritunl 1.29.2145.25 allows attackers to enumerate valid VPN usernames via a series of /auth/session login attempts. Initially, the server will return error 401. However, if the username is valid, then after 20 login attempts, the server will start responding with error 400. Invalid usernames will receive error 401 indefinitely. Note: This has been disputed by the vendor as not a vulnerability. They argue that this is an intended design
Open full assessment ↗ - CVE-2020-25199
Vulnerability Details
View details for CVE-2020-25199
A heap-based buffer overflow vulnerability exists within the WECON LeviStudioU Release Build 2019-09-21 and prior when processing project files. Opening a specially crafted project file could allow an attacker to exploit and execute code under the privileges of the application.
Open full assessment ↗ - CVE-2020-25198
MOXA NPort IAW5000A-I/O Series
View details for CVE-2020-25198
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has incorrectly implemented protections from session fixation, which may allow an attacker to gain access to a session and hijack it by stealing the user’s cookies.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25197
GE Reason RT43X Clocks Code Injection
View details for CVE-2020-25197
A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25196
MOXA NPort IAW5000A-I/O Series
View details for CVE-2020-25196
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows SSH/Telnet sessions, which may be vulnerable to brute force attacks to bypass authentication.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25195
Vulnerability Details
View details for CVE-2020-25195
The length of the input fields of Host Engineering H0-ECOM100, H2-ECOM100, and H4-ECOM100 modules are verified only on the client side when receiving input from the configuration web server, which may allow an attacker to bypass the check and send input to crash the device.
Open full assessment ↗ - CVE-2020-25194
MOXA NPort IAW5000A-I/O Series
View details for CVE-2020-25194
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower has improper privilege management, which may allow an attacker with user privileges to perform requests with administrative privileges.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25193
GE Reason RT43X Clocks Use of Hard-coded Cryptographic Key
View details for CVE-2020-25193
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25192
MOXA NPort IAW5000A-I/O Series
View details for CVE-2020-25192
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without proper authorization.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25191
Vulnerability Details
View details for CVE-2020-25191
Incorrect permissions are set by default for an API entry-point of a specific service, allowing a non-authenticated user to trigger a function that could reboot the CompactRIO (Driver versions prior to 20.5) remotely.
Open full assessment ↗ - CVE-2020-25190
MOXA NPort IAW5000A-I/O Series
View details for CVE-2020-25190
The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party services in cleartext.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25189
Vulnerability Details
View details for CVE-2020-25189
The affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09).
Open full assessment ↗ - CVE-2020-25188
Vulnerability Details
View details for CVE-2020-25188
An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the application due to an out-of-bounds read vulnerability on the LAquis SCADA (Versions prior to 4.3.1.870).
Open full assessment ↗ - CVE-2020-25187
Medtronic MyCareLink Smart Heap-based Buffer Overflow
View details for CVE-2020-25187
Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25186
Vulnerability Details
View details for CVE-2020-25186
An XXE vulnerability exists within LeviStudioU Release Build 2019-09-21 and prior when processing parameter entities, which may allow file disclosure.
Open full assessment ↗ - CVE-2020-25185
Vulnerability Details
View details for CVE-2020-25185
The affected product is vulnerable to five post-authentication buffer overflows, which may allow a logged in user to remotely execute arbitrary code on the IP150 (firmware versions 5.02.09).
Open full assessment ↗ - CVE-2020-25184
Rockwell Automation ISaGRAF5 Runtime Unprotected Storage of Credentials
View details for CVE-2020-25184
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25183
Medtronic MyCareLink Smart Improper Authentication
View details for CVE-2020-25183
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25182
Rockwell Automation ISaGRAF5 Runtime Uncontrolled Search Path Element
View details for CVE-2020-25182
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25181
Vulnerability Details
View details for CVE-2020-25181
WECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary code execution.
Open full assessment ↗ - CVE-2020-25180
Rockwell Automation ISaGRAF5 Runtime Use of Hard-coded Cryptographic Key
View details for CVE-2020-25180
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25179
Vulnerability Details
View details for CVE-2020-25179
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
Open full assessment ↗ - CVE-2020-25178
Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information
View details for CVE-2020-25178
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25177
Vulnerability Details
View details for CVE-2020-25177
WECON PLC Editor Versions 1.3.8 and prior has a stack-based buffer overflow vulnerability has been identified that may allow arbitrary code execution.
Open full assessment ↗