- CVE-2020-25176
Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal
View details for CVE-2020-25176
Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25175
Vulnerability Details
View details for CVE-2020-25175
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
Open full assessment ↗ - CVE-2020-25174
B. Braun OnlineSuite
View details for CVE-2020-25174
A DLL hijacking vulnerability in the B. Braun OnlineSuite Version AP 3.0 and earlier allows local attackers to execute code on the system as a high privileged user.
Open full assessment ↗ - CVE-2020-25173
Reolink P2P Cameras
View details for CVE-2020-25173
An attacker with local network access can obtain a fixed cryptography key which may allow for further compromise of Reolink P2P cameras outside of local network access
Open full assessment ↗ - CVE-2020-25172
B. Braun OnlineSuite
View details for CVE-2020-25172
A relative path traversal attack in the B. Braun OnlineSuite Version AP 3.0 and earlier allows unauthenticated attackers to upload or download arbitrary files.
Open full assessment ↗ - CVE-2020-25171
Fuji Electric V-Server Lite
View details for CVE-2020-25171
The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
Open full assessment ↗ - CVE-2020-25170
B. Braun OnlineSuite
View details for CVE-2020-25170
An Excel Macro Injection vulnerability exists in the export feature in the B. Braun OnlineSuite Version AP 3.0 and earlier via multiple input fields that are mishandled in an Excel export.
Open full assessment ↗ - CVE-2020-25169
Reolink P2P Cameras
View details for CVE-2020-25169
The affected Reolink P2P products do not sufficiently protect data transferred between the local device and Reolink servers. This can allow an attacker to access sensitive information, such as camera feeds.
Open full assessment ↗ - CVE-2020-25168
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
View details for CVE-2020-25168
Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25167
OSIsoft PI Vision Incorrect Authorization
View details for CVE-2020-25167
OSIsoft PI Vision 2020 versions prior to 3.5.0 could disclose information to a user with insufficient privileges for an AF attribute.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25166
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
View details for CVE-2020-25166
An improper verification of the cryptographic signature of firmware updates of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to generate valid firmware updates with arbitrary content that can be used to tamper with devices.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25165
Vulnerability Details
View details for CVE-2020-25165
BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a network session authentication vulnerability within the authentication process between specified versions of the BD Alaris PC Unit and the BD Alaris Systems Manager. If exploited, an attacker could perform a denial-of-service attack on the BD Alaris PC Unit by modifying the configuration headers of data in transit. A denial-of-service attack could lead to a drop in the wireless capability of the BD Alaris PC Unit, resulting in manual operation of the PC Unit.
Open full assessment ↗ - CVE-2020-25164
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
View details for CVE-2020-25164
A vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to recover user credentials of the administrative interface.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25163
OSIsoft PI Vision Cross-site Scripting
View details for CVE-2020-25163
A remote attacker with write access to PI ProcessBook files could inject code that is imported into OSIsoft PI Vision 2020 versions prior to 3.5.0. Unauthorized information disclosure, modification, or deletion is also possible if a victim views or interacts with the infected display. This vulnerability affects PI System data and other data accessible with victim’s user permissions.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25162
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
View details for CVE-2020-25162
A XPath injection vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows unauthenticated remote attackers to access sensitive information and escalate privileges.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25161
Vulnerability Details
View details for CVE-2020-25161
The WADashboard component of WebAccess/SCADA Versions 9.0 and prior may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.
Open full assessment ↗ - CVE-2020-25160
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
View details for CVE-2020-25160
Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25159
Real Time Automation EtherNet/IP
View details for CVE-2020-25159
499ES EtherNet/IP (ENIP) Adaptor Source Code is vulnerable to a stack-based buffer overflow, which may allow an attacker to send a specially crafted packet that may result in a denial-of-service condition or code execution.
Open full assessment ↗ - CVE-2020-25158
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
View details for CVE-2020-25158
A reflected cross-site scripting (XSS) vulnerability in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows remote attackers to inject arbitrary web script or HTML into various locations.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25157
Vulnerability Details
View details for CVE-2020-25157
The R-SeeNet webpage (1.5.1 through 2.4.10) suffers from SQL injection, which allows a remote attacker to invoke queries on the database and retrieve sensitive information.
Open full assessment ↗ - CVE-2020-25156
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
View details for CVE-2020-25156
Active debug code in the B. Braun Melsungen AG SpaceCom Version L8/U61, and the Data module compactplus Versions A10 and A11 and earlier enables attackers in possession of cryptographic material to access the device as root.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25155
Vulnerability Details
View details for CVE-2020-25155
The affected product transmits unencrypted sensitive information, which may allow an attacker to access this information on the NIO 50 (all versions).
Open full assessment ↗ - CVE-2020-25154
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
View details for CVE-2020-25154
An open redirect vulnerability in the administrative interface of the B. Braun Melsungen AG SpaceCom device Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 allows attackers to redirect users to malicious websites.
icscert · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-25153
MOXA NPort IAW5000A-I/O Series
View details for CVE-2020-25153
The built-in web service for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower does not require users to have strong passwords.
icscert · Calculated from the published vector.
Open full assessment ↗