CVE 2020 Directory: Page 525
Filters use provider-reported Base scores in the saved snapshot. Cards calculate the complete published vector, which may include additional metric groups. Search is limited to this identifier year. Change year.
19,402 published records with identifiers assigned to 2020. The identifier year is not necessarily the publication year. Snapshot: 2026-10-22.
Page 525 of 809
- CVE-2020-8506
Vulnerability Details
View details for CVE-2020-8506
The Global TV application 2.3.2 for Android and 4.7.5 for iOS sends Unencrypted Analytics.
Open full assessment ↗ - CVE-2020-8505
Vulnerability Details
View details for CVE-2020-8505
School Management Software PHP/mySQL through 2019-03-14 allows office_admin/?action=deleteadmin CSRF to delete a user.
Open full assessment ↗ - CVE-2020-8504
Vulnerability Details
View details for CVE-2020-8504
School Management Software PHP/mySQL through 2019-03-14 allows office_admin/?action=addadmin CSRF to add an administrative user.
Open full assessment ↗ - CVE-2020-8503
Vulnerability Details
View details for CVE-2020-8503
Biscom Secure File Transfer (SFT) 5.0.1050 through 5.1.1067 and 6.0.1000 through 6.0.1003 allows Insecure Direct Object Reference (IDOR) by an authenticated sender because of an error in a file-upload feature. This is fixed in 5.1.1068 and 6.0.1004.
Open full assessment ↗ - CVE-2020-8500
Vulnerability Details
View details for CVE-2020-8500
In Artica Pandora FMS 7.42, Web Admin users can execute arbitrary code by uploading a .php file via the Updater or Extension component. NOTE: The vendor reports that this is intended functionality
Open full assessment ↗ - CVE-2020-8498
Vulnerability Details
View details for CVE-2020-8498
XSS exists in the shortcode functionality of the GistPress plugin before 3.0.2 for WordPress via the includes/class-gistpress.php id parameter. This allows an attacker with the WordPress Contributor role to execute arbitrary JavaScript code with the privileges of other users (e.g., ones who have the publish_posts capability).
Open full assessment ↗ - CVE-2020-8497
Vulnerability Details
View details for CVE-2020-8497
In Artica Pandora FMS through 7.42, an unauthenticated attacker can read the chat history. The file is in JSON format and it contains user names, user IDs, private messages, and timestamps.
Open full assessment ↗ - CVE-2020-8496
Vulnerability Details
View details for CVE-2020-8496
In Kronos Web Time and Attendance (webTA) 4.1.x and later 4.x versions before 5.0, there is a Stored XSS vulnerability by setting the Application Banner input field of the /ApplicationBanner page as an authenticated administrator.
Open full assessment ↗ - CVE-2020-8495
Vulnerability Details
View details for CVE-2020-8495
In Kronos Web Time and Attendance (webTA) 3.8.x and later 3.x versions before 4.0, the com.threeis.webta.H491delegate servlet allows an attacker with Timekeeper or Supervisor privileges to gain unauthorized administrative privileges within the application via the delegate, delegateRole, and delegatorUserId parameters.
Open full assessment ↗ - CVE-2020-8494
Vulnerability Details
View details for CVE-2020-8494
In Kronos Web Time and Attendance (webTA) 3.8.x and later 3.x versions before 4.0, the com.threeis.webta.H402editUser servlet allows an attacker with Timekeeper, Master Timekeeper, or HR Admin privileges to gain unauthorized administrative privileges within the application via the emp_id, userid, pw1, pw2, supervisor, and timekeeper parameters.
Open full assessment ↗ - CVE-2020-8493
Vulnerability Details
View details for CVE-2020-8493
A stored XSS vulnerability in Kronos Web Time and Attendance (webTA) affects 3.8.x and later 3.x versions before 4.0 via multiple input fields (Login Message, Banner Message, and Password Instructions) of the com.threeis.webta.H261configMenu servlet via an authenticated administrator.
Open full assessment ↗ - CVE-2020-8492
Vulnerability Details
View details for CVE-2020-8492
Python 2.7 through 2.7.17, 3.5 through 3.5.9, 3.6 through 3.6.10, 3.7 through 3.7.6, and 3.8 through 3.8.1 allows an HTTP server to conduct Regular Expression Denial of Service (ReDoS) attacks against a client because of urllib.request.AbstractBasicAuthHandler catastrophic backtracking.
CISA-ADP · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8489
ABB System 800xA Inter process communication vulnerability - 800xA Information Management
View details for CVE-2020-8489
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8488
ABB System 800xA Inter process communication vulnerability - 800xA Batch Management
View details for CVE-2020-8488
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8487
ABB System 800xA Inter process communication vulnerability - System 800xA Base
View details for CVE-2020-8487
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8486
ABB System 800xA Inter process communication vulnerability - 800xA RNRP
View details for CVE-2020-8486
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8485
ABB System 800xA Inter process communication vulnerability - 800xA for Mod 300
View details for CVE-2020-8485
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8484
ABB System 800xA Inter process communication vulnerability - 800xA for DCI
View details for CVE-2020-8484
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8482
ABB Device Library Wizard Information Disclosure Vulnerability
View details for CVE-2020-8482
Insecure storage of sensitive information in ABB Device Library Wizard versions 6.0.X, 6.0.3.1 and 6.0.3.2 allows unauthenticated low privilege user to read file that contains confidential data
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8481
ABB Central Licensing System - Information disclosure
View details for CVE-2020-8481
For ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8479
ABB Central Licensing System - XML External Entity Injection
View details for CVE-2020-8479
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5. an XML External Entity Injection vulnerability exists that allows an attacker to read or call arbitrary files from the license server and/or from the network and also block the license handling.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8478
ABB System 800xA Inter process communication vulnerability
View details for CVE-2020-8478
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8477
ABB System 800xA Information Manager Remote Code Execution
View details for CVE-2020-8477
The installations for ABB System 800xA Information Manager versions 5.1, 6.0 to 6.0.3.2 and 6.1 wrongly contain an auxiliary component. An attacker is able to use this for an XSS-like attack to an authenticated local user, which might lead to execution of arbitrary code.
ABB · Calculated from the published vector.
Open full assessment ↗ - CVE-2020-8476
ABB Central Licensing System - Elevation of Privilege Vulnerability
View details for CVE-2020-8476
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, ABB AbilityTM SCADAvantage versions 5.1 to 5.6.5, a weakness in validation of input exists that allows an attacker to alter licenses assigned to the system nodes by sending specially crafted messages to the CLS web service.
ABB · Calculated from the published vector.
Open full assessment ↗